mirror of
https://github.com/Aurorastation/Aurora-Old.git
synced 2026-08-29 15:46:26 +01:00
Bay Merge 05NOV2014
Known errors: * A set of errors tied to updating the fire overlays. * A single error related to a dischephency between new and old slime code * A set of errors related to the recharging of stun batons * A single error due to old machinery code coming from your grav generator file * A single error error from your space cooler code, due to old atmopsherics code * A playerpanel warning * An error tied to extinguishing and old atmos code.
This commit is contained in:
@@ -1,6 +1,18 @@
|
||||
#define DEFAULT_PRESSURE_DELTA 10000
|
||||
|
||||
#define EXTERNAL_PRESSURE_BOUND ONE_ATMOSPHERE
|
||||
#define INTERNAL_PRESSURE_BOUND 0
|
||||
#define PRESSURE_CHECKS 1
|
||||
|
||||
#define PRESSURE_CHECK_EXTERNAL 1
|
||||
#define PRESSURE_CHECK_INPUT 2
|
||||
#define PRESSURE_CHECK_OUTPUT 4
|
||||
|
||||
#undefine
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump
|
||||
icon = 'icons/obj/atmospherics/dp_vent_pump.dmi'
|
||||
icon_state = "off"
|
||||
icon = 'icons/atmos/vent_pump.dmi'
|
||||
icon_state = "map_dp_vent"
|
||||
|
||||
//node2 is output port
|
||||
//node1 is input port
|
||||
@@ -10,190 +22,246 @@
|
||||
|
||||
level = 1
|
||||
|
||||
high_volume
|
||||
name = "Large Dual Port Air Vent"
|
||||
|
||||
New()
|
||||
..()
|
||||
|
||||
air1.volume = 1000
|
||||
air2.volume = 1000
|
||||
use_power = 1
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
active_power_usage = 7500 //This also doubles as a measure of how powerful the pump is, in Watts. 7500 W ~ 10 HP
|
||||
var/last_power_draw = 0
|
||||
|
||||
var/on = 0
|
||||
var/pump_direction = 1 //0 = siphoning, 1 = releasing
|
||||
|
||||
var/external_pressure_bound = ONE_ATMOSPHERE
|
||||
var/input_pressure_min = 0
|
||||
var/output_pressure_max = 0
|
||||
|
||||
var/pressure_checks = 1
|
||||
//1: Do not pass external_pressure_bound
|
||||
//2: Do not pass input_pressure_min
|
||||
//4: Do not pass output_pressure_max
|
||||
|
||||
update_icon()
|
||||
if(on)
|
||||
if(pump_direction)
|
||||
icon_state = "[level == 1 && istype(loc, /turf/simulated) ? "h" : "" ]out"
|
||||
else
|
||||
icon_state = "[level == 1 && istype(loc, /turf/simulated) ? "h" : "" ]in"
|
||||
else
|
||||
icon_state = "[level == 1 && istype(loc, /turf/simulated) ? "h" : "" ]off"
|
||||
on = 0
|
||||
|
||||
return
|
||||
|
||||
hide(var/i) //to make the little pipe section invisible, the icon changes.
|
||||
if(on)
|
||||
if(pump_direction)
|
||||
icon_state = "[i == 1 && istype(loc, /turf/simulated) ? "h" : "" ]out"
|
||||
else
|
||||
icon_state = "[i == 1 && istype(loc, /turf/simulated) ? "h" : "" ]in"
|
||||
else
|
||||
icon_state = "[i == 1 && istype(loc, /turf/simulated) ? "h" : "" ]off"
|
||||
on = 0
|
||||
return
|
||||
|
||||
process()
|
||||
..()
|
||||
|
||||
if(!on)
|
||||
return 0
|
||||
|
||||
var/datum/gas_mixture/environment = loc.return_air()
|
||||
var/environment_pressure = environment.return_pressure()
|
||||
|
||||
if(pump_direction) //input -> external
|
||||
var/pressure_delta = 10000
|
||||
|
||||
if(pressure_checks&1)
|
||||
pressure_delta = min(pressure_delta, (external_pressure_bound - environment_pressure))
|
||||
if(pressure_checks&2)
|
||||
pressure_delta = min(pressure_delta, (air1.return_pressure() - input_pressure_min))
|
||||
|
||||
if(pressure_delta > 0)
|
||||
if(air1.temperature > 0)
|
||||
var/transfer_moles = pressure_delta*environment.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
|
||||
|
||||
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
|
||||
|
||||
loc.assume_air(removed)
|
||||
|
||||
if(network1)
|
||||
network1.update = 1
|
||||
|
||||
else //external -> output
|
||||
var/pressure_delta = 10000
|
||||
|
||||
if(pressure_checks&1)
|
||||
pressure_delta = min(pressure_delta, (environment_pressure - external_pressure_bound))
|
||||
if(pressure_checks&4)
|
||||
pressure_delta = min(pressure_delta, (output_pressure_max - air2.return_pressure()))
|
||||
|
||||
if(pressure_delta > 0)
|
||||
if(environment.temperature > 0)
|
||||
var/transfer_moles = pressure_delta*air2.volume/(environment.temperature * R_IDEAL_GAS_EQUATION)
|
||||
|
||||
var/datum/gas_mixture/removed = loc.remove_air(transfer_moles)
|
||||
|
||||
air2.merge(removed)
|
||||
|
||||
if(network2)
|
||||
network2.update = 1
|
||||
|
||||
return 1
|
||||
|
||||
//Radio remote control
|
||||
|
||||
proc
|
||||
set_frequency(new_frequency)
|
||||
radio_controller.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
||||
|
||||
broadcast_status()
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = 1 //radio signal
|
||||
signal.source = src
|
||||
|
||||
signal.data = list(
|
||||
"tag" = id,
|
||||
"device" = "ADVP",
|
||||
"power" = on,
|
||||
"direction" = pump_direction?("release"):("siphon"),
|
||||
"checks" = pressure_checks,
|
||||
"input" = input_pressure_min,
|
||||
"output" = output_pressure_max,
|
||||
"external" = external_pressure_bound,
|
||||
"sigtype" = "status"
|
||||
)
|
||||
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
||||
|
||||
return 1
|
||||
var/external_pressure_bound = EXTERNAL_PRESSURE_BOUND
|
||||
var/input_pressure_min = INTERNAL_PRESSURE_BOUND
|
||||
var/output_pressure_max = DEFAULT_PRESSURE_DELTA
|
||||
|
||||
var/frequency = 0
|
||||
var/id = null
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
initialize()
|
||||
..()
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
var/pressure_checks = PRESSURE_CHECK_EXTERNAL
|
||||
//1: Do not pass external_pressure_bound
|
||||
//2: Do not pass input_pressure_min
|
||||
//4: Do not pass output_pressure_max
|
||||
|
||||
receive_signal(datum/signal/signal)
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/New()
|
||||
..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
icon = null
|
||||
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
if("power" in signal.data)
|
||||
on = text2num(signal.data["power"])
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume
|
||||
name = "Large Dual Port Air Vent"
|
||||
|
||||
if("power_toggle" in signal.data)
|
||||
on = !on
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/New()
|
||||
..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
|
||||
|
||||
if("direction" in signal.data)
|
||||
pump_direction = text2num(signal.data["direction"])
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/update_icon(var/safety = 0)
|
||||
if(!check_icon_cache())
|
||||
return
|
||||
|
||||
if("checks" in signal.data)
|
||||
pressure_checks = text2num(signal.data["checks"])
|
||||
overlays.Cut()
|
||||
|
||||
var/vent_icon = "vent"
|
||||
|
||||
if("purge" in signal.data)
|
||||
pressure_checks &= ~1
|
||||
pump_direction = 0
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
|
||||
if("stabalize" in signal.data)
|
||||
pressure_checks |= 1
|
||||
pump_direction = 1
|
||||
if(T.intact && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
|
||||
vent_icon += "h"
|
||||
|
||||
if(!powered())
|
||||
vent_icon += "off"
|
||||
else
|
||||
vent_icon += "[on ? "[pump_direction ? "out" : "in"]" : "off"]"
|
||||
|
||||
if("set_input_pressure" in signal.data)
|
||||
input_pressure_min = between(
|
||||
0,
|
||||
text2num(signal.data["set_input_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
overlays += icon_manager.get_atmos_icon("device", , , vent_icon)
|
||||
|
||||
if("set_output_pressure" in signal.data)
|
||||
output_pressure_max = between(
|
||||
0,
|
||||
text2num(signal.data["set_output_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/update_underlays()
|
||||
if(..())
|
||||
underlays.Cut()
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
if(T.intact && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
|
||||
return
|
||||
else
|
||||
add_underlay(T, node1, turn(dir, -180))
|
||||
add_underlay(T, node2, dir)
|
||||
|
||||
if("set_external_pressure" in signal.data)
|
||||
external_pressure_bound = between(
|
||||
0,
|
||||
text2num(signal.data["set_external_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/hide(var/i)
|
||||
update_icon()
|
||||
update_underlays()
|
||||
|
||||
if("status" in signal.data)
|
||||
spawn(2)
|
||||
broadcast_status()
|
||||
return //do not update_icon
|
||||
//if(signal.data["tag"])
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/process()
|
||||
..()
|
||||
|
||||
if(stat & (NOPOWER|BROKEN) || !on)
|
||||
update_use_power(0) //usually we get here because a player turned a pump off - definitely want to update.
|
||||
last_power_draw = 0
|
||||
last_flow_rate = 0
|
||||
return 0
|
||||
|
||||
var/datum/gas_mixture/environment = loc.return_air()
|
||||
|
||||
var/power_draw = -1
|
||||
|
||||
//Figure out the target pressure difference
|
||||
var/pressure_delta = get_pressure_delta(environment)
|
||||
|
||||
if(pressure_delta > 0.5)
|
||||
if(pump_direction) //internal -> external
|
||||
if (node1 && (environment.temperature || air1.temperature))
|
||||
var/output_volume = environment.volume * environment.group_multiplier
|
||||
var/air_temperature = environment.temperature? environment.temperature : air1.temperature
|
||||
var/transfer_moles = pressure_delta*output_volume/(air_temperature * R_IDEAL_GAS_EQUATION)
|
||||
|
||||
power_draw = pump_gas(src, air1, environment, transfer_moles, active_power_usage)
|
||||
|
||||
if(power_draw >= 0 && network1)
|
||||
network1.update = 1
|
||||
else //external -> internal
|
||||
if (node2 && (environment.temperature || air2.temperature))
|
||||
var/output_volume = air2.volume + (network2? network2.volume : 0)
|
||||
var/air_temperature = air2.temperature? air2.temperature : environment.temperature
|
||||
var/transfer_moles = pressure_delta*output_volume/(air_temperature * R_IDEAL_GAS_EQUATION)
|
||||
|
||||
//limit flow rate from turfs
|
||||
transfer_moles = min(transfer_moles, environment.total_moles*air2.volume/environment.volume) //group_multiplier gets divided out here
|
||||
|
||||
power_draw = pump_gas(src, environment, air2, transfer_moles, active_power_usage)
|
||||
|
||||
if(power_draw >= 0 && network2)
|
||||
network2.update = 1
|
||||
|
||||
if (power_draw < 0)
|
||||
last_power_draw = 0
|
||||
last_flow_rate = 0
|
||||
//update_use_power(0)
|
||||
use_power = 0 //don't force update - easier on CPU
|
||||
else
|
||||
last_power_draw = handle_power_draw(power_draw)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/get_pressure_delta(datum/gas_mixture/environment)
|
||||
var/pressure_delta = DEFAULT_PRESSURE_DELTA
|
||||
var/environment_pressure = environment.return_pressure()
|
||||
|
||||
if(pump_direction) //internal -> external
|
||||
if(pressure_checks & PRESSURE_CHECK_EXTERNAL)
|
||||
pressure_delta = min(pressure_delta, external_pressure_bound - environment_pressure) //increasing the pressure here
|
||||
if(pressure_checks & PRESSURE_CHECK_INPUT)
|
||||
pressure_delta = min(pressure_delta, air1.return_pressure() - input_pressure_min) //decreasing the pressure here
|
||||
else //external -> internal
|
||||
if(pressure_checks & PRESSURE_CHECK_EXTERNAL)
|
||||
pressure_delta = min(pressure_delta, environment_pressure - external_pressure_bound) //decreasing the pressure here
|
||||
if(pressure_checks & PRESSURE_CHECK_OUTPUT)
|
||||
pressure_delta = min(pressure_delta, output_pressure_max - air2.return_pressure()) //increasing the pressure here
|
||||
|
||||
return pressure_delta
|
||||
|
||||
|
||||
//Radio remote control
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/set_frequency(new_frequency)
|
||||
radio_controller.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/broadcast_status()
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = 1 //radio signal
|
||||
signal.source = src
|
||||
|
||||
signal.data = list(
|
||||
"tag" = id,
|
||||
"device" = "ADVP",
|
||||
"power" = on,
|
||||
"direction" = pump_direction?("release"):("siphon"),
|
||||
"checks" = pressure_checks,
|
||||
"input" = input_pressure_min,
|
||||
"output" = output_pressure_max,
|
||||
"external" = external_pressure_bound,
|
||||
"sigtype" = "status"
|
||||
)
|
||||
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/initialize()
|
||||
..()
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/examine()
|
||||
set src in oview(1)
|
||||
..()
|
||||
|
||||
if (get_dist(usr, src) <= 1)
|
||||
usr << "A small gauge in the corner reads [round(last_flow_rate, 0.1)] L/s; [round(last_power_draw)] W"
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_pump/power_change()
|
||||
var/old_stat = stat
|
||||
..()
|
||||
if(old_stat != stat)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/receive_signal(datum/signal/signal)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
if(signal.data["power"])
|
||||
on = text2num(signal.data["power"])
|
||||
|
||||
if(signal.data["power_toggle"])
|
||||
on = !on
|
||||
|
||||
if(signal.data["direction"])
|
||||
pump_direction = text2num(signal.data["direction"])
|
||||
|
||||
if(signal.data["checks"])
|
||||
pressure_checks = text2num(signal.data["checks"])
|
||||
|
||||
if(signal.data["purge"])
|
||||
pressure_checks &= ~1
|
||||
pump_direction = 0
|
||||
|
||||
if(signal.data["stabalize"])
|
||||
pressure_checks |= 1
|
||||
pump_direction = 1
|
||||
|
||||
if(signal.data["set_input_pressure"])
|
||||
input_pressure_min = between(
|
||||
0,
|
||||
text2num(signal.data["set_input_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["set_output_pressure"])
|
||||
output_pressure_max = between(
|
||||
0,
|
||||
text2num(signal.data["set_output_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["set_external_pressure"])
|
||||
external_pressure_bound = between(
|
||||
0,
|
||||
text2num(signal.data["set_external_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["status"])
|
||||
spawn(2)
|
||||
broadcast_status()
|
||||
update_icon()
|
||||
return //do not update_icon
|
||||
|
||||
spawn(2)
|
||||
broadcast_status()
|
||||
update_icon()
|
||||
Reference in New Issue
Block a user