- The unpower all areas event now does not unpower engineering and the AI core, meaning the AI is less likely to get screwed over by this and it is no longer a 'release singularity' button.
git-svn-id: http://tgstation13.googlecode.com/svn/trunk@3086 316c924e-a436-60f5-8080-3fe189b3f50e
This commit is contained in:
@@ -88,9 +88,6 @@
|
||||
/proc/power_failure()
|
||||
command_alert("Abnormal activity detected in [station_name()]'s powernet. As a precautionary measure, the station's power will be shut off for an indeterminate duration.", "Critical Power Failure")
|
||||
world << sound('poweroff.ogg')
|
||||
for(var/obj/machinery/power/apc/C in world)
|
||||
if(C.cell && C.z == 1)
|
||||
C.cell.charge = 0
|
||||
for(var/obj/machinery/power/smes/S in world)
|
||||
if(istype(get_area(S), /area/turret_protected) || S.z != 1)
|
||||
continue
|
||||
@@ -99,12 +96,41 @@
|
||||
S.online = 0
|
||||
S.updateicon()
|
||||
S.power_change()
|
||||
|
||||
var/list/skipped_areas = list(/area/engine/engineering, /area/turret_protected/ai)
|
||||
|
||||
for(var/area/A in world)
|
||||
if(A.name != "Space" && A.name != "Engine Walls" && A.name != "Chemical Lab Test Chamber" && A.name != "Escape Shuttle" && A.name != "Arrival Area" && A.name != "Arrival Shuttle" && A.name != "start area" && A.name != "Engine Combustion Chamber")
|
||||
A.power_light = 0
|
||||
A.power_equip = 0
|
||||
A.power_environ = 0
|
||||
A.power_change()
|
||||
if( !A.requires_power || A.always_unpowered )
|
||||
continue
|
||||
|
||||
var/skip = 0
|
||||
for(var/area_type in skipped_areas)
|
||||
if(istype(A,area_type))
|
||||
skip = 1
|
||||
break
|
||||
if(A.contents)
|
||||
for(var/atom/AT in A.contents)
|
||||
if(AT.z != 1) //Only check one, it's enough.
|
||||
skip = 1
|
||||
break
|
||||
if(skip) continue
|
||||
A.power_light = 0
|
||||
A.power_equip = 0
|
||||
A.power_environ = 0
|
||||
A.power_change()
|
||||
|
||||
for(var/obj/machinery/power/apc/C in world)
|
||||
if(C.cell && C.z == 1)
|
||||
var/area/A = get_area(C)
|
||||
|
||||
var/skip = 0
|
||||
for(var/area_type in skipped_areas)
|
||||
if(istype(A,area_type))
|
||||
skip = 1
|
||||
break
|
||||
if(skip) continue
|
||||
|
||||
C.cell.charge = 0
|
||||
|
||||
/proc/power_restore()
|
||||
command_alert("Power has been restored to [station_name()]. We apologize for the inconvenience.", "Power Systems Nominal")
|
||||
|
||||
Reference in New Issue