mirror of
https://github.com/Aurorastation/Aurora.3.git
synced 2026-08-25 14:00:18 +01:00
Enforces Lineendings and adds Editorconfig (#7657)
This commit is contained in:
@@ -1,134 +1,134 @@
|
||||
obj/machinery/atmospherics/binary
|
||||
dir = SOUTH
|
||||
initialize_directions = SOUTH|NORTH
|
||||
use_power = 1
|
||||
|
||||
var/datum/gas_mixture/air1
|
||||
var/datum/gas_mixture/air2
|
||||
|
||||
var/datum/pipe_network/network1
|
||||
var/datum/pipe_network/network2
|
||||
|
||||
Initialize()
|
||||
switch(dir)
|
||||
if(NORTH)
|
||||
initialize_directions = NORTH|SOUTH
|
||||
if(SOUTH)
|
||||
initialize_directions = NORTH|SOUTH
|
||||
if(EAST)
|
||||
initialize_directions = EAST|WEST
|
||||
if(WEST)
|
||||
initialize_directions = EAST|WEST
|
||||
air1 = new
|
||||
air2 = new
|
||||
|
||||
air1.volume = 200
|
||||
air2.volume = 200
|
||||
. = ..()
|
||||
|
||||
// Housekeeping and pipe network stuff below
|
||||
network_expand(datum/pipe_network/new_network, obj/machinery/atmospherics/pipe/reference)
|
||||
if(reference == node1)
|
||||
network1 = new_network
|
||||
|
||||
else if(reference == node2)
|
||||
network2 = new_network
|
||||
|
||||
if(new_network.normal_members.Find(src))
|
||||
return 0
|
||||
|
||||
new_network.normal_members += src
|
||||
|
||||
return null
|
||||
|
||||
Destroy()
|
||||
QDEL_NULL(air1)
|
||||
QDEL_NULL(air2)
|
||||
|
||||
if(node1)
|
||||
node1.disconnect(src)
|
||||
QDEL_NULL(network1)
|
||||
if(node2)
|
||||
node2.disconnect(src)
|
||||
QDEL_NULL(network2)
|
||||
|
||||
node1 = null
|
||||
node2 = null
|
||||
|
||||
return ..()
|
||||
|
||||
atmos_init()
|
||||
if(node1 && node2) return
|
||||
|
||||
var/node2_connect = dir
|
||||
var/node1_connect = turn(dir, 180)
|
||||
|
||||
for(var/obj/machinery/atmospherics/target in get_step(src,node1_connect))
|
||||
if(target.initialize_directions & get_dir(target,src))
|
||||
if (check_connect_types(target,src))
|
||||
node1 = target
|
||||
break
|
||||
|
||||
for(var/obj/machinery/atmospherics/target in get_step(src,node2_connect))
|
||||
if(target.initialize_directions & get_dir(target,src))
|
||||
if (check_connect_types(target,src))
|
||||
node2 = target
|
||||
break
|
||||
|
||||
update_icon()
|
||||
update_underlays()
|
||||
|
||||
build_network()
|
||||
if(!network1 && node1)
|
||||
network1 = new /datum/pipe_network()
|
||||
network1.normal_members += src
|
||||
network1.build_network(node1, src)
|
||||
|
||||
if(!network2 && node2)
|
||||
network2 = new /datum/pipe_network()
|
||||
network2.normal_members += src
|
||||
network2.build_network(node2, src)
|
||||
|
||||
|
||||
return_network(obj/machinery/atmospherics/reference)
|
||||
build_network()
|
||||
|
||||
if(reference==node1)
|
||||
return network1
|
||||
|
||||
if(reference==node2)
|
||||
return network2
|
||||
|
||||
return null
|
||||
|
||||
reassign_network(datum/pipe_network/old_network, datum/pipe_network/new_network)
|
||||
if(network1 == old_network)
|
||||
network1 = new_network
|
||||
if(network2 == old_network)
|
||||
network2 = new_network
|
||||
|
||||
return 1
|
||||
|
||||
return_network_air(datum/pipe_network/reference)
|
||||
var/list/results = list()
|
||||
|
||||
if(network1 == reference)
|
||||
results += air1
|
||||
if(network2 == reference)
|
||||
results += air2
|
||||
|
||||
return results
|
||||
|
||||
disconnect(obj/machinery/atmospherics/reference)
|
||||
if(reference==node1)
|
||||
qdel(network1)
|
||||
node1 = null
|
||||
|
||||
else if(reference==node2)
|
||||
qdel(network2)
|
||||
node2 = null
|
||||
|
||||
update_icon()
|
||||
update_underlays()
|
||||
|
||||
return null
|
||||
obj/machinery/atmospherics/binary
|
||||
dir = SOUTH
|
||||
initialize_directions = SOUTH|NORTH
|
||||
use_power = 1
|
||||
|
||||
var/datum/gas_mixture/air1
|
||||
var/datum/gas_mixture/air2
|
||||
|
||||
var/datum/pipe_network/network1
|
||||
var/datum/pipe_network/network2
|
||||
|
||||
Initialize()
|
||||
switch(dir)
|
||||
if(NORTH)
|
||||
initialize_directions = NORTH|SOUTH
|
||||
if(SOUTH)
|
||||
initialize_directions = NORTH|SOUTH
|
||||
if(EAST)
|
||||
initialize_directions = EAST|WEST
|
||||
if(WEST)
|
||||
initialize_directions = EAST|WEST
|
||||
air1 = new
|
||||
air2 = new
|
||||
|
||||
air1.volume = 200
|
||||
air2.volume = 200
|
||||
. = ..()
|
||||
|
||||
// Housekeeping and pipe network stuff below
|
||||
network_expand(datum/pipe_network/new_network, obj/machinery/atmospherics/pipe/reference)
|
||||
if(reference == node1)
|
||||
network1 = new_network
|
||||
|
||||
else if(reference == node2)
|
||||
network2 = new_network
|
||||
|
||||
if(new_network.normal_members.Find(src))
|
||||
return 0
|
||||
|
||||
new_network.normal_members += src
|
||||
|
||||
return null
|
||||
|
||||
Destroy()
|
||||
QDEL_NULL(air1)
|
||||
QDEL_NULL(air2)
|
||||
|
||||
if(node1)
|
||||
node1.disconnect(src)
|
||||
QDEL_NULL(network1)
|
||||
if(node2)
|
||||
node2.disconnect(src)
|
||||
QDEL_NULL(network2)
|
||||
|
||||
node1 = null
|
||||
node2 = null
|
||||
|
||||
return ..()
|
||||
|
||||
atmos_init()
|
||||
if(node1 && node2) return
|
||||
|
||||
var/node2_connect = dir
|
||||
var/node1_connect = turn(dir, 180)
|
||||
|
||||
for(var/obj/machinery/atmospherics/target in get_step(src,node1_connect))
|
||||
if(target.initialize_directions & get_dir(target,src))
|
||||
if (check_connect_types(target,src))
|
||||
node1 = target
|
||||
break
|
||||
|
||||
for(var/obj/machinery/atmospherics/target in get_step(src,node2_connect))
|
||||
if(target.initialize_directions & get_dir(target,src))
|
||||
if (check_connect_types(target,src))
|
||||
node2 = target
|
||||
break
|
||||
|
||||
update_icon()
|
||||
update_underlays()
|
||||
|
||||
build_network()
|
||||
if(!network1 && node1)
|
||||
network1 = new /datum/pipe_network()
|
||||
network1.normal_members += src
|
||||
network1.build_network(node1, src)
|
||||
|
||||
if(!network2 && node2)
|
||||
network2 = new /datum/pipe_network()
|
||||
network2.normal_members += src
|
||||
network2.build_network(node2, src)
|
||||
|
||||
|
||||
return_network(obj/machinery/atmospherics/reference)
|
||||
build_network()
|
||||
|
||||
if(reference==node1)
|
||||
return network1
|
||||
|
||||
if(reference==node2)
|
||||
return network2
|
||||
|
||||
return null
|
||||
|
||||
reassign_network(datum/pipe_network/old_network, datum/pipe_network/new_network)
|
||||
if(network1 == old_network)
|
||||
network1 = new_network
|
||||
if(network2 == old_network)
|
||||
network2 = new_network
|
||||
|
||||
return 1
|
||||
|
||||
return_network_air(datum/pipe_network/reference)
|
||||
var/list/results = list()
|
||||
|
||||
if(network1 == reference)
|
||||
results += air1
|
||||
if(network2 == reference)
|
||||
results += air2
|
||||
|
||||
return results
|
||||
|
||||
disconnect(obj/machinery/atmospherics/reference)
|
||||
if(reference==node1)
|
||||
qdel(network1)
|
||||
node1 = null
|
||||
|
||||
else if(reference==node2)
|
||||
qdel(network2)
|
||||
node2 = null
|
||||
|
||||
update_icon()
|
||||
update_underlays()
|
||||
|
||||
return null
|
||||
|
||||
@@ -1,145 +1,145 @@
|
||||
//node1, air1, network1 correspond to input
|
||||
//node2, air2, network2 correspond to output
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator
|
||||
name = "circulator"
|
||||
desc = "A gas circulator turbine and heat exchanger."
|
||||
icon = 'icons/obj/pipes.dmi'
|
||||
icon_state = "circ-off"
|
||||
anchored = 0
|
||||
|
||||
var/kinetic_efficiency = 0.04 //combined kinetic and kinetic-to-electric efficiency
|
||||
var/volume_ratio = 0.2
|
||||
|
||||
var/recent_moles_transferred = 0
|
||||
var/last_heat_capacity = 0
|
||||
var/last_temperature = 0
|
||||
var/last_pressure_delta = 0
|
||||
var/last_worldtime_transfer = 0
|
||||
var/last_stored_energy_transferred = 0
|
||||
var/volume_capacity_used = 0
|
||||
var/stored_energy = 0
|
||||
|
||||
density = 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/Initialize()
|
||||
. = ..()
|
||||
desc = initial(desc) + " Its outlet port is to the [dir2text(dir)]."
|
||||
air1.volume = 400
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/proc/return_transfer_air()
|
||||
var/datum/gas_mixture/removed
|
||||
if(anchored && !(stat&BROKEN) && network1)
|
||||
var/input_starting_pressure = air1.return_pressure()
|
||||
var/output_starting_pressure = air2.return_pressure()
|
||||
last_pressure_delta = max(input_starting_pressure - output_starting_pressure - 5, 0)
|
||||
|
||||
//only circulate air if there is a pressure difference (plus 5kPa kinetic, 10kPa static friction)
|
||||
if(air1.temperature > 0 && last_pressure_delta > 5)
|
||||
|
||||
//Calculate necessary moles to transfer using PV = nRT
|
||||
recent_moles_transferred = (last_pressure_delta*network1.volume/(air1.temperature * R_IDEAL_GAS_EQUATION))/3 //uses the volume of the whole network, not just itself
|
||||
volume_capacity_used = min( (last_pressure_delta*network1.volume/3)/(input_starting_pressure*air1.volume) , 1) //how much of the gas in the input air volume is consumed
|
||||
|
||||
//Calculate energy generated from kinetic turbine
|
||||
stored_energy += 1/ADIABATIC_EXPONENT * min(last_pressure_delta * network1.volume , input_starting_pressure*air1.volume) * (1 - volume_ratio**ADIABATIC_EXPONENT) * kinetic_efficiency
|
||||
|
||||
//Actually transfer the gas
|
||||
removed = air1.remove(recent_moles_transferred)
|
||||
if(removed)
|
||||
last_heat_capacity = removed.heat_capacity()
|
||||
last_temperature = removed.temperature
|
||||
|
||||
//Update the gas networks.
|
||||
network1.update = 1
|
||||
|
||||
last_worldtime_transfer = world.time
|
||||
else
|
||||
recent_moles_transferred = 0
|
||||
|
||||
update_icon()
|
||||
return removed
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/proc/return_stored_energy()
|
||||
last_stored_energy_transferred = stored_energy
|
||||
stored_energy = 0
|
||||
return last_stored_energy_transferred
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/machinery_process()
|
||||
..()
|
||||
|
||||
if(last_worldtime_transfer < world.time - 50)
|
||||
recent_moles_transferred = 0
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/update_icon()
|
||||
if(stat & (BROKEN|NOPOWER) || !anchored)
|
||||
icon_state = "circ-p"
|
||||
else if(last_pressure_delta > 0 && recent_moles_transferred > 0)
|
||||
if(last_pressure_delta > 5*ONE_ATMOSPHERE)
|
||||
icon_state = "circ-run"
|
||||
else
|
||||
icon_state = "circ-slow"
|
||||
else
|
||||
icon_state = "circ-off"
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/attackby(obj/item/W as obj, mob/user as mob)
|
||||
if (W.iswrench())
|
||||
playsound(src.loc, W.usesound, 75, 1)
|
||||
anchored = !anchored
|
||||
user.visible_message("[user.name] [anchored ? "secures" : "unsecures"] the bolts holding [src.name] to the floor.", \
|
||||
"You [anchored ? "secure" : "unsecure"] the bolts holding [src] to the floor.", \
|
||||
"You hear a ratchet")
|
||||
|
||||
if(anchored)
|
||||
if(dir & (NORTH|SOUTH))
|
||||
initialize_directions = NORTH|SOUTH
|
||||
else if(dir & (EAST|WEST))
|
||||
initialize_directions = EAST|WEST
|
||||
|
||||
atmos_init()
|
||||
build_network()
|
||||
if (node1)
|
||||
node1.atmos_init()
|
||||
node1.build_network()
|
||||
if (node2)
|
||||
node2.atmos_init()
|
||||
node2.build_network()
|
||||
else
|
||||
if(node1)
|
||||
node1.disconnect(src)
|
||||
qdel(network1)
|
||||
if(node2)
|
||||
node2.disconnect(src)
|
||||
qdel(network2)
|
||||
|
||||
node1 = null
|
||||
node2 = null
|
||||
|
||||
else
|
||||
..()
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/verb/rotate_clockwise()
|
||||
set category = "Object"
|
||||
set name = "Rotate Circulator (Clockwise)"
|
||||
set src in view(1)
|
||||
|
||||
if (usr.stat || usr.restrained() || anchored)
|
||||
return
|
||||
|
||||
src.set_dir(turn(src.dir, 90))
|
||||
desc = initial(desc) + " Its outlet port is to the [dir2text(dir)]."
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/verb/rotate_anticlockwise()
|
||||
set category = "Object"
|
||||
set name = "Rotate Circulator (Counterclockwise)"
|
||||
set src in view(1)
|
||||
|
||||
if (usr.stat || usr.restrained() || anchored)
|
||||
return
|
||||
|
||||
src.set_dir(turn(src.dir, -90))
|
||||
desc = initial(desc) + " Its outlet port is to the [dir2text(dir)]."
|
||||
//node1, air1, network1 correspond to input
|
||||
//node2, air2, network2 correspond to output
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator
|
||||
name = "circulator"
|
||||
desc = "A gas circulator turbine and heat exchanger."
|
||||
icon = 'icons/obj/pipes.dmi'
|
||||
icon_state = "circ-off"
|
||||
anchored = 0
|
||||
|
||||
var/kinetic_efficiency = 0.04 //combined kinetic and kinetic-to-electric efficiency
|
||||
var/volume_ratio = 0.2
|
||||
|
||||
var/recent_moles_transferred = 0
|
||||
var/last_heat_capacity = 0
|
||||
var/last_temperature = 0
|
||||
var/last_pressure_delta = 0
|
||||
var/last_worldtime_transfer = 0
|
||||
var/last_stored_energy_transferred = 0
|
||||
var/volume_capacity_used = 0
|
||||
var/stored_energy = 0
|
||||
|
||||
density = 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/Initialize()
|
||||
. = ..()
|
||||
desc = initial(desc) + " Its outlet port is to the [dir2text(dir)]."
|
||||
air1.volume = 400
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/proc/return_transfer_air()
|
||||
var/datum/gas_mixture/removed
|
||||
if(anchored && !(stat&BROKEN) && network1)
|
||||
var/input_starting_pressure = air1.return_pressure()
|
||||
var/output_starting_pressure = air2.return_pressure()
|
||||
last_pressure_delta = max(input_starting_pressure - output_starting_pressure - 5, 0)
|
||||
|
||||
//only circulate air if there is a pressure difference (plus 5kPa kinetic, 10kPa static friction)
|
||||
if(air1.temperature > 0 && last_pressure_delta > 5)
|
||||
|
||||
//Calculate necessary moles to transfer using PV = nRT
|
||||
recent_moles_transferred = (last_pressure_delta*network1.volume/(air1.temperature * R_IDEAL_GAS_EQUATION))/3 //uses the volume of the whole network, not just itself
|
||||
volume_capacity_used = min( (last_pressure_delta*network1.volume/3)/(input_starting_pressure*air1.volume) , 1) //how much of the gas in the input air volume is consumed
|
||||
|
||||
//Calculate energy generated from kinetic turbine
|
||||
stored_energy += 1/ADIABATIC_EXPONENT * min(last_pressure_delta * network1.volume , input_starting_pressure*air1.volume) * (1 - volume_ratio**ADIABATIC_EXPONENT) * kinetic_efficiency
|
||||
|
||||
//Actually transfer the gas
|
||||
removed = air1.remove(recent_moles_transferred)
|
||||
if(removed)
|
||||
last_heat_capacity = removed.heat_capacity()
|
||||
last_temperature = removed.temperature
|
||||
|
||||
//Update the gas networks.
|
||||
network1.update = 1
|
||||
|
||||
last_worldtime_transfer = world.time
|
||||
else
|
||||
recent_moles_transferred = 0
|
||||
|
||||
update_icon()
|
||||
return removed
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/proc/return_stored_energy()
|
||||
last_stored_energy_transferred = stored_energy
|
||||
stored_energy = 0
|
||||
return last_stored_energy_transferred
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/machinery_process()
|
||||
..()
|
||||
|
||||
if(last_worldtime_transfer < world.time - 50)
|
||||
recent_moles_transferred = 0
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/update_icon()
|
||||
if(stat & (BROKEN|NOPOWER) || !anchored)
|
||||
icon_state = "circ-p"
|
||||
else if(last_pressure_delta > 0 && recent_moles_transferred > 0)
|
||||
if(last_pressure_delta > 5*ONE_ATMOSPHERE)
|
||||
icon_state = "circ-run"
|
||||
else
|
||||
icon_state = "circ-slow"
|
||||
else
|
||||
icon_state = "circ-off"
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/attackby(obj/item/W as obj, mob/user as mob)
|
||||
if (W.iswrench())
|
||||
playsound(src.loc, W.usesound, 75, 1)
|
||||
anchored = !anchored
|
||||
user.visible_message("[user.name] [anchored ? "secures" : "unsecures"] the bolts holding [src.name] to the floor.", \
|
||||
"You [anchored ? "secure" : "unsecure"] the bolts holding [src] to the floor.", \
|
||||
"You hear a ratchet")
|
||||
|
||||
if(anchored)
|
||||
if(dir & (NORTH|SOUTH))
|
||||
initialize_directions = NORTH|SOUTH
|
||||
else if(dir & (EAST|WEST))
|
||||
initialize_directions = EAST|WEST
|
||||
|
||||
atmos_init()
|
||||
build_network()
|
||||
if (node1)
|
||||
node1.atmos_init()
|
||||
node1.build_network()
|
||||
if (node2)
|
||||
node2.atmos_init()
|
||||
node2.build_network()
|
||||
else
|
||||
if(node1)
|
||||
node1.disconnect(src)
|
||||
qdel(network1)
|
||||
if(node2)
|
||||
node2.disconnect(src)
|
||||
qdel(network2)
|
||||
|
||||
node1 = null
|
||||
node2 = null
|
||||
|
||||
else
|
||||
..()
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/verb/rotate_clockwise()
|
||||
set category = "Object"
|
||||
set name = "Rotate Circulator (Clockwise)"
|
||||
set src in view(1)
|
||||
|
||||
if (usr.stat || usr.restrained() || anchored)
|
||||
return
|
||||
|
||||
src.set_dir(turn(src.dir, 90))
|
||||
desc = initial(desc) + " Its outlet port is to the [dir2text(dir)]."
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/binary/circulator/verb/rotate_anticlockwise()
|
||||
set category = "Object"
|
||||
set name = "Rotate Circulator (Counterclockwise)"
|
||||
set src in view(1)
|
||||
|
||||
if (usr.stat || usr.restrained() || anchored)
|
||||
return
|
||||
|
||||
src.set_dir(turn(src.dir, -90))
|
||||
desc = initial(desc) + " Its outlet port is to the [dir2text(dir)]."
|
||||
|
||||
@@ -1,265 +1,265 @@
|
||||
#define DEFAULT_PRESSURE_DELTA 10000
|
||||
|
||||
#define EXTERNAL_PRESSURE_BOUND ONE_ATMOSPHERE
|
||||
#define INTERNAL_PRESSURE_BOUND 0
|
||||
#define PRESSURE_CHECKS 1
|
||||
|
||||
#define PRESSURE_CHECK_EXTERNAL 1
|
||||
#define PRESSURE_CHECK_INPUT 2
|
||||
#define PRESSURE_CHECK_OUTPUT 4
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump
|
||||
icon = 'icons/atmos/vent_pump.dmi'
|
||||
icon_state = "map_dp_vent"
|
||||
|
||||
//node2 is output port
|
||||
//node1 is input port
|
||||
|
||||
name = "Dual Port Air Vent"
|
||||
desc = "Has a valve and pump attached to it. There are two ports."
|
||||
|
||||
level = 1
|
||||
|
||||
use_power = 0
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //7500 W ~ 10 HP
|
||||
|
||||
connect_types = CONNECT_TYPE_REGULAR|CONNECT_TYPE_SUPPLY|CONNECT_TYPE_SCRUBBER //connects to regular, supply and scrubbers pipes
|
||||
|
||||
var/pump_direction = 1 //0 = siphoning, 1 = releasing
|
||||
|
||||
var/external_pressure_bound = EXTERNAL_PRESSURE_BOUND
|
||||
var/input_pressure_min = INTERNAL_PRESSURE_BOUND
|
||||
var/output_pressure_max = DEFAULT_PRESSURE_DELTA
|
||||
|
||||
var/frequency = 0
|
||||
var/id = null
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
var/pressure_checks = PRESSURE_CHECK_EXTERNAL
|
||||
//1: Do not pass external_pressure_bound
|
||||
//2: Do not pass input_pressure_min
|
||||
//4: Do not pass output_pressure_max
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/Initialize()
|
||||
. = ..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
icon = null
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume
|
||||
name = "Large Dual Port Air Vent"
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/Initialize()
|
||||
. = ..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/update_icon(var/safety = 0)
|
||||
if(!check_icon_cache())
|
||||
return
|
||||
|
||||
var/istate = ""
|
||||
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
|
||||
if(!T.is_plating() && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
|
||||
istate += "h"
|
||||
|
||||
if(!powered())
|
||||
istate += "off"
|
||||
else
|
||||
istate += "[use_power ? "[pump_direction ? "out" : "in"]" : "off"]"
|
||||
|
||||
icon_state = istate
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/update_underlays()
|
||||
if(..())
|
||||
underlays.Cut()
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
if(!T.is_plating() && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
|
||||
return
|
||||
else
|
||||
if (node1)
|
||||
add_underlay(T, node1, turn(dir, -180), node1.icon_connect_type)
|
||||
else
|
||||
add_underlay(T, node1, turn(dir, -180))
|
||||
if (node2)
|
||||
add_underlay(T, node2, dir, node2.icon_connect_type)
|
||||
else
|
||||
add_underlay(T, node2, dir)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/hide(var/i)
|
||||
update_icon()
|
||||
update_underlays()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/machinery_process()
|
||||
..()
|
||||
|
||||
last_power_draw = 0
|
||||
last_flow_rate = 0
|
||||
|
||||
if(stat & (NOPOWER|BROKEN) || !use_power)
|
||||
return 0
|
||||
|
||||
var/datum/gas_mixture/environment = loc.return_air()
|
||||
|
||||
var/power_draw = -1
|
||||
|
||||
//Figure out the target pressure difference
|
||||
var/pressure_delta = get_pressure_delta(environment)
|
||||
|
||||
if(pressure_delta > 0.5)
|
||||
if(pump_direction) //internal -> external
|
||||
if (node1 && (environment.temperature || air1.temperature))
|
||||
var/transfer_moles = calculate_transfer_moles(air1, environment, pressure_delta)
|
||||
power_draw = pump_gas(src, air1, environment, transfer_moles, power_rating)
|
||||
|
||||
if(power_draw >= 0 && network1)
|
||||
network1.update = 1
|
||||
else //external -> internal
|
||||
if (node2 && (environment.temperature || air2.temperature))
|
||||
var/transfer_moles = calculate_transfer_moles(environment, air2, pressure_delta, (network2)? network2.volume : 0)
|
||||
|
||||
//limit flow rate from turfs
|
||||
transfer_moles = min(transfer_moles, environment.total_moles*air2.volume/environment.volume) //group_multiplier gets divided out here
|
||||
power_draw = pump_gas(src, environment, air2, transfer_moles, power_rating)
|
||||
|
||||
if(power_draw >= 0 && network2)
|
||||
network2.update = 1
|
||||
|
||||
if (power_draw >= 0)
|
||||
last_power_draw = power_draw
|
||||
use_power(power_draw)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/get_pressure_delta(datum/gas_mixture/environment)
|
||||
var/pressure_delta = DEFAULT_PRESSURE_DELTA
|
||||
var/environment_pressure = environment.return_pressure()
|
||||
|
||||
if(pump_direction) //internal -> external
|
||||
if(pressure_checks & PRESSURE_CHECK_EXTERNAL)
|
||||
pressure_delta = min(pressure_delta, external_pressure_bound - environment_pressure) //increasing the pressure here
|
||||
if(pressure_checks & PRESSURE_CHECK_INPUT)
|
||||
pressure_delta = min(pressure_delta, air1.return_pressure() - input_pressure_min) //decreasing the pressure here
|
||||
else //external -> internal
|
||||
if(pressure_checks & PRESSURE_CHECK_EXTERNAL)
|
||||
pressure_delta = min(pressure_delta, environment_pressure - external_pressure_bound) //decreasing the pressure here
|
||||
if(pressure_checks & PRESSURE_CHECK_OUTPUT)
|
||||
pressure_delta = min(pressure_delta, output_pressure_max - air2.return_pressure()) //increasing the pressure here
|
||||
|
||||
return pressure_delta
|
||||
|
||||
|
||||
//Radio remote control
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/set_frequency(new_frequency)
|
||||
SSradio.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/broadcast_status()
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = 1 //radio signal
|
||||
signal.source = src
|
||||
|
||||
signal.data = list(
|
||||
"tag" = id,
|
||||
"device" = "ADVP",
|
||||
"power" = use_power,
|
||||
"direction" = pump_direction?("release"):("siphon"),
|
||||
"checks" = pressure_checks,
|
||||
"input" = input_pressure_min,
|
||||
"output" = output_pressure_max,
|
||||
"external" = external_pressure_bound,
|
||||
"sigtype" = "status"
|
||||
)
|
||||
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/atmos_init()
|
||||
..()
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/examine(mob/user)
|
||||
if(..(user, 1))
|
||||
to_chat(user, "A small gauge in the corner reads [round(last_flow_rate, 0.1)] L/s; [round(last_power_draw)] W")
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_pump/power_change()
|
||||
var/old_stat = stat
|
||||
..()
|
||||
if(old_stat != stat)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/receive_signal(datum/signal/signal)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
if(signal.data["power"])
|
||||
use_power = text2num(signal.data["power"])
|
||||
|
||||
if(signal.data["power_toggle"])
|
||||
use_power = !use_power
|
||||
|
||||
if(signal.data["direction"])
|
||||
pump_direction = text2num(signal.data["direction"])
|
||||
|
||||
if(signal.data["checks"])
|
||||
pressure_checks = text2num(signal.data["checks"])
|
||||
|
||||
if(signal.data["purge"])
|
||||
pressure_checks &= ~1
|
||||
pump_direction = 0
|
||||
|
||||
if(signal.data["stabalize"])
|
||||
pressure_checks |= 1
|
||||
pump_direction = 1
|
||||
|
||||
if(signal.data["set_input_pressure"])
|
||||
input_pressure_min = between(
|
||||
0,
|
||||
text2num(signal.data["set_input_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["set_output_pressure"])
|
||||
output_pressure_max = between(
|
||||
0,
|
||||
text2num(signal.data["set_output_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["set_external_pressure"])
|
||||
external_pressure_bound = between(
|
||||
0,
|
||||
text2num(signal.data["set_external_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["status"])
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
return //do not update_icon
|
||||
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
update_icon()
|
||||
|
||||
#undef DEFAULT_PRESSURE_DELTA
|
||||
|
||||
#undef EXTERNAL_PRESSURE_BOUND
|
||||
#undef INTERNAL_PRESSURE_BOUND
|
||||
#undef PRESSURE_CHECKS
|
||||
|
||||
#undef PRESSURE_CHECK_EXTERNAL
|
||||
#undef PRESSURE_CHECK_INPUT
|
||||
#undef PRESSURE_CHECK_OUTPUT
|
||||
#define DEFAULT_PRESSURE_DELTA 10000
|
||||
|
||||
#define EXTERNAL_PRESSURE_BOUND ONE_ATMOSPHERE
|
||||
#define INTERNAL_PRESSURE_BOUND 0
|
||||
#define PRESSURE_CHECKS 1
|
||||
|
||||
#define PRESSURE_CHECK_EXTERNAL 1
|
||||
#define PRESSURE_CHECK_INPUT 2
|
||||
#define PRESSURE_CHECK_OUTPUT 4
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump
|
||||
icon = 'icons/atmos/vent_pump.dmi'
|
||||
icon_state = "map_dp_vent"
|
||||
|
||||
//node2 is output port
|
||||
//node1 is input port
|
||||
|
||||
name = "Dual Port Air Vent"
|
||||
desc = "Has a valve and pump attached to it. There are two ports."
|
||||
|
||||
level = 1
|
||||
|
||||
use_power = 0
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //7500 W ~ 10 HP
|
||||
|
||||
connect_types = CONNECT_TYPE_REGULAR|CONNECT_TYPE_SUPPLY|CONNECT_TYPE_SCRUBBER //connects to regular, supply and scrubbers pipes
|
||||
|
||||
var/pump_direction = 1 //0 = siphoning, 1 = releasing
|
||||
|
||||
var/external_pressure_bound = EXTERNAL_PRESSURE_BOUND
|
||||
var/input_pressure_min = INTERNAL_PRESSURE_BOUND
|
||||
var/output_pressure_max = DEFAULT_PRESSURE_DELTA
|
||||
|
||||
var/frequency = 0
|
||||
var/id = null
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
var/pressure_checks = PRESSURE_CHECK_EXTERNAL
|
||||
//1: Do not pass external_pressure_bound
|
||||
//2: Do not pass input_pressure_min
|
||||
//4: Do not pass output_pressure_max
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/Initialize()
|
||||
. = ..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
icon = null
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume
|
||||
name = "Large Dual Port Air Vent"
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/Initialize()
|
||||
. = ..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP + 800
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/update_icon(var/safety = 0)
|
||||
if(!check_icon_cache())
|
||||
return
|
||||
|
||||
var/istate = ""
|
||||
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
|
||||
if(!T.is_plating() && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
|
||||
istate += "h"
|
||||
|
||||
if(!powered())
|
||||
istate += "off"
|
||||
else
|
||||
istate += "[use_power ? "[pump_direction ? "out" : "in"]" : "off"]"
|
||||
|
||||
icon_state = istate
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/update_underlays()
|
||||
if(..())
|
||||
underlays.Cut()
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
if(!T.is_plating() && node1 && node2 && node1.level == 1 && node2.level == 1 && istype(node1, /obj/machinery/atmospherics/pipe) && istype(node2, /obj/machinery/atmospherics/pipe))
|
||||
return
|
||||
else
|
||||
if (node1)
|
||||
add_underlay(T, node1, turn(dir, -180), node1.icon_connect_type)
|
||||
else
|
||||
add_underlay(T, node1, turn(dir, -180))
|
||||
if (node2)
|
||||
add_underlay(T, node2, dir, node2.icon_connect_type)
|
||||
else
|
||||
add_underlay(T, node2, dir)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/hide(var/i)
|
||||
update_icon()
|
||||
update_underlays()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/machinery_process()
|
||||
..()
|
||||
|
||||
last_power_draw = 0
|
||||
last_flow_rate = 0
|
||||
|
||||
if(stat & (NOPOWER|BROKEN) || !use_power)
|
||||
return 0
|
||||
|
||||
var/datum/gas_mixture/environment = loc.return_air()
|
||||
|
||||
var/power_draw = -1
|
||||
|
||||
//Figure out the target pressure difference
|
||||
var/pressure_delta = get_pressure_delta(environment)
|
||||
|
||||
if(pressure_delta > 0.5)
|
||||
if(pump_direction) //internal -> external
|
||||
if (node1 && (environment.temperature || air1.temperature))
|
||||
var/transfer_moles = calculate_transfer_moles(air1, environment, pressure_delta)
|
||||
power_draw = pump_gas(src, air1, environment, transfer_moles, power_rating)
|
||||
|
||||
if(power_draw >= 0 && network1)
|
||||
network1.update = 1
|
||||
else //external -> internal
|
||||
if (node2 && (environment.temperature || air2.temperature))
|
||||
var/transfer_moles = calculate_transfer_moles(environment, air2, pressure_delta, (network2)? network2.volume : 0)
|
||||
|
||||
//limit flow rate from turfs
|
||||
transfer_moles = min(transfer_moles, environment.total_moles*air2.volume/environment.volume) //group_multiplier gets divided out here
|
||||
power_draw = pump_gas(src, environment, air2, transfer_moles, power_rating)
|
||||
|
||||
if(power_draw >= 0 && network2)
|
||||
network2.update = 1
|
||||
|
||||
if (power_draw >= 0)
|
||||
last_power_draw = power_draw
|
||||
use_power(power_draw)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/get_pressure_delta(datum/gas_mixture/environment)
|
||||
var/pressure_delta = DEFAULT_PRESSURE_DELTA
|
||||
var/environment_pressure = environment.return_pressure()
|
||||
|
||||
if(pump_direction) //internal -> external
|
||||
if(pressure_checks & PRESSURE_CHECK_EXTERNAL)
|
||||
pressure_delta = min(pressure_delta, external_pressure_bound - environment_pressure) //increasing the pressure here
|
||||
if(pressure_checks & PRESSURE_CHECK_INPUT)
|
||||
pressure_delta = min(pressure_delta, air1.return_pressure() - input_pressure_min) //decreasing the pressure here
|
||||
else //external -> internal
|
||||
if(pressure_checks & PRESSURE_CHECK_EXTERNAL)
|
||||
pressure_delta = min(pressure_delta, environment_pressure - external_pressure_bound) //decreasing the pressure here
|
||||
if(pressure_checks & PRESSURE_CHECK_OUTPUT)
|
||||
pressure_delta = min(pressure_delta, output_pressure_max - air2.return_pressure()) //increasing the pressure here
|
||||
|
||||
return pressure_delta
|
||||
|
||||
|
||||
//Radio remote control
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/set_frequency(new_frequency)
|
||||
SSradio.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/proc/broadcast_status()
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = 1 //radio signal
|
||||
signal.source = src
|
||||
|
||||
signal.data = list(
|
||||
"tag" = id,
|
||||
"device" = "ADVP",
|
||||
"power" = use_power,
|
||||
"direction" = pump_direction?("release"):("siphon"),
|
||||
"checks" = pressure_checks,
|
||||
"input" = input_pressure_min,
|
||||
"output" = output_pressure_max,
|
||||
"external" = external_pressure_bound,
|
||||
"sigtype" = "status"
|
||||
)
|
||||
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/atmos_init()
|
||||
..()
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/examine(mob/user)
|
||||
if(..(user, 1))
|
||||
to_chat(user, "A small gauge in the corner reads [round(last_flow_rate, 0.1)] L/s; [round(last_power_draw)] W")
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/unary/vent_pump/power_change()
|
||||
var/old_stat = stat
|
||||
..()
|
||||
if(old_stat != stat)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/receive_signal(datum/signal/signal)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
if(signal.data["power"])
|
||||
use_power = text2num(signal.data["power"])
|
||||
|
||||
if(signal.data["power_toggle"])
|
||||
use_power = !use_power
|
||||
|
||||
if(signal.data["direction"])
|
||||
pump_direction = text2num(signal.data["direction"])
|
||||
|
||||
if(signal.data["checks"])
|
||||
pressure_checks = text2num(signal.data["checks"])
|
||||
|
||||
if(signal.data["purge"])
|
||||
pressure_checks &= ~1
|
||||
pump_direction = 0
|
||||
|
||||
if(signal.data["stabalize"])
|
||||
pressure_checks |= 1
|
||||
pump_direction = 1
|
||||
|
||||
if(signal.data["set_input_pressure"])
|
||||
input_pressure_min = between(
|
||||
0,
|
||||
text2num(signal.data["set_input_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["set_output_pressure"])
|
||||
output_pressure_max = between(
|
||||
0,
|
||||
text2num(signal.data["set_output_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["set_external_pressure"])
|
||||
external_pressure_bound = between(
|
||||
0,
|
||||
text2num(signal.data["set_external_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["status"])
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
return //do not update_icon
|
||||
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
update_icon()
|
||||
|
||||
#undef DEFAULT_PRESSURE_DELTA
|
||||
|
||||
#undef EXTERNAL_PRESSURE_BOUND
|
||||
#undef INTERNAL_PRESSURE_BOUND
|
||||
#undef PRESSURE_CHECKS
|
||||
|
||||
#undef PRESSURE_CHECK_EXTERNAL
|
||||
#undef PRESSURE_CHECK_INPUT
|
||||
#undef PRESSURE_CHECK_OUTPUT
|
||||
|
||||
@@ -1,261 +1,261 @@
|
||||
#define REGULATE_NONE 0
|
||||
#define REGULATE_INPUT 1 //shuts off when input side is below the target pressure
|
||||
#define REGULATE_OUTPUT 2 //shuts off when output side is above the target pressure
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate
|
||||
icon = 'icons/atmos/passive_gate.dmi'
|
||||
icon_state = "map"
|
||||
level = 1
|
||||
|
||||
name = "pressure regulator"
|
||||
desc = "A one-way air valve that can be used to regulate input or output pressure, and flow rate. Does not require power."
|
||||
|
||||
use_power = 0
|
||||
interact_offline = 1
|
||||
var/unlocked = 0 //If 0, then the valve is locked closed, otherwise it is open(-able, it's a one-way valve so it closes if gas would flow backwards).
|
||||
var/target_pressure = ONE_ATMOSPHERE
|
||||
var/max_pressure_setting = 15000 //kPa
|
||||
var/set_flow_rate = ATMOS_DEFAULT_VOLUME_PUMP * 2.5
|
||||
var/regulate_mode = REGULATE_OUTPUT
|
||||
|
||||
var/flowing = 0 //for icons - becomes zero if the valve closes itself due to regulation mode
|
||||
|
||||
var/frequency = 0
|
||||
var/id = null
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/Initialize()
|
||||
. = ..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP * 2.5
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP * 2.5
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/update_icon()
|
||||
icon_state = (unlocked && flowing)? "on" : "off"
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/update_underlays()
|
||||
if(..())
|
||||
underlays.Cut()
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
add_underlay(T, node1, turn(dir, 180))
|
||||
add_underlay(T, node2, dir)
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/hide(var/i)
|
||||
update_underlays()
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/machinery_process()
|
||||
..()
|
||||
|
||||
last_flow_rate = 0
|
||||
|
||||
if(!unlocked)
|
||||
return 0
|
||||
|
||||
var/output_starting_pressure = air2.return_pressure()
|
||||
var/input_starting_pressure = air1.return_pressure()
|
||||
|
||||
var/pressure_delta
|
||||
switch (regulate_mode)
|
||||
if (REGULATE_INPUT)
|
||||
pressure_delta = input_starting_pressure - target_pressure
|
||||
if (REGULATE_OUTPUT)
|
||||
pressure_delta = target_pressure - output_starting_pressure
|
||||
|
||||
//-1 if pump_gas() did not move any gas, >= 0 otherwise
|
||||
var/returnval = -1
|
||||
if((regulate_mode == REGULATE_NONE || pressure_delta > 0.01) && (air1.temperature > 0 || air2.temperature > 0)) //since it's basically a valve, it makes sense to check both temperatures
|
||||
flowing = 1
|
||||
|
||||
//flow rate limit
|
||||
var/transfer_moles = (set_flow_rate/air1.volume)*air1.total_moles
|
||||
|
||||
//Figure out how much gas to transfer to meet the target pressure.
|
||||
switch (regulate_mode)
|
||||
if (REGULATE_INPUT)
|
||||
transfer_moles = min(transfer_moles, calculate_transfer_moles(air2, air1, pressure_delta, (network1)? network1.volume : 0))
|
||||
if (REGULATE_OUTPUT)
|
||||
transfer_moles = min(transfer_moles, calculate_transfer_moles(air1, air2, pressure_delta, (network2)? network2.volume : 0))
|
||||
|
||||
//pump_gas() will return a negative number if no flow occurred
|
||||
returnval = pump_gas_passive(src, air1, air2, transfer_moles)
|
||||
|
||||
if (returnval >= 0)
|
||||
if(network1)
|
||||
network1.update = 1
|
||||
|
||||
if(network2)
|
||||
network2.update = 1
|
||||
|
||||
if (last_flow_rate)
|
||||
flowing = 1
|
||||
|
||||
update_icon()
|
||||
|
||||
|
||||
//Radio remote control
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/proc/set_frequency(new_frequency)
|
||||
SSradio.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/proc/broadcast_status()
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = 1 //radio signal
|
||||
signal.source = src
|
||||
|
||||
signal.data = list(
|
||||
"tag" = id,
|
||||
"device" = "AGP",
|
||||
"power" = unlocked,
|
||||
"target_output" = target_pressure,
|
||||
"regulate_mode" = regulate_mode,
|
||||
"set_flow_rate" = set_flow_rate,
|
||||
"sigtype" = "status"
|
||||
)
|
||||
|
||||
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/atmos_init()
|
||||
..()
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/receive_signal(datum/signal/signal)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
|
||||
if("power" in signal.data)
|
||||
unlocked = text2num(signal.data["power"])
|
||||
|
||||
if("power_toggle" in signal.data)
|
||||
unlocked = !unlocked
|
||||
|
||||
if("set_target_pressure" in signal.data)
|
||||
target_pressure = between(
|
||||
0,
|
||||
text2num(signal.data["set_target_pressure"]),
|
||||
max_pressure_setting
|
||||
)
|
||||
|
||||
if("set_regulate_mode" in signal.data)
|
||||
regulate_mode = text2num(signal.data["set_regulate_mode"])
|
||||
|
||||
if("set_flow_rate" in signal.data)
|
||||
regulate_mode = text2num(signal.data["set_flow_rate"])
|
||||
|
||||
if("status" in signal.data)
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
return //do not update_icon
|
||||
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
update_icon()
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/attack_hand(user as mob)
|
||||
if(..())
|
||||
return
|
||||
src.add_fingerprint(usr)
|
||||
if(!src.allowed(user))
|
||||
to_chat(user, "<span class='warning'>Access denied.</span>")
|
||||
return
|
||||
usr.set_machine(src)
|
||||
ui_interact(user)
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1)
|
||||
if(stat & (BROKEN|NOPOWER))
|
||||
return
|
||||
|
||||
// this is the data which will be sent to the ui
|
||||
var/data[0]
|
||||
|
||||
data = list(
|
||||
"on" = unlocked,
|
||||
"pressure_set" = round(target_pressure*100), //Nano UI can't handle rounded non-integers, apparently.
|
||||
"max_pressure" = max_pressure_setting,
|
||||
"input_pressure" = round(air1.return_pressure()*100),
|
||||
"output_pressure" = round(air2.return_pressure()*100),
|
||||
"regulate_mode" = regulate_mode,
|
||||
"set_flow_rate" = round(set_flow_rate*10),
|
||||
"last_flow_rate" = round(last_flow_rate*10)
|
||||
)
|
||||
|
||||
// update the ui if it exists, returns null if no ui is passed/found
|
||||
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, data, force_open)
|
||||
if (!ui)
|
||||
// the ui does not exist, so we'll create a new() one
|
||||
// for a list of parameters and their descriptions see the code docs in \code\modules\nano\nanoui.dm
|
||||
ui = new(user, src, ui_key, "pressure_regulator.tmpl", name, 470, 370)
|
||||
ui.set_initial_data(data) // when the ui is first opened this is the data it will use
|
||||
ui.open() // open the new ui window
|
||||
ui.set_auto_update(1) // auto update every Master Controller tick
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/Topic(href,href_list)
|
||||
if(..()) return 1
|
||||
|
||||
if(href_list["toggle_valve"])
|
||||
unlocked = !unlocked
|
||||
|
||||
if(href_list["regulate_mode"])
|
||||
switch(href_list["regulate_mode"])
|
||||
if ("off") regulate_mode = REGULATE_NONE
|
||||
if ("input") regulate_mode = REGULATE_INPUT
|
||||
if ("output") regulate_mode = REGULATE_OUTPUT
|
||||
|
||||
switch(href_list["set_press"])
|
||||
if ("min")
|
||||
target_pressure = 0
|
||||
if ("max")
|
||||
target_pressure = max_pressure_setting
|
||||
if ("set")
|
||||
var/new_pressure = input(usr,"Enter new output pressure (0-[max_pressure_setting]kPa)","Pressure Control",src.target_pressure) as num
|
||||
src.target_pressure = between(0, new_pressure, max_pressure_setting)
|
||||
|
||||
switch(href_list["set_flow_rate"])
|
||||
if ("min")
|
||||
set_flow_rate = 0
|
||||
if ("max")
|
||||
set_flow_rate = air1.volume
|
||||
if ("set")
|
||||
var/new_flow_rate = input(usr,"Enter new flow rate limit (0-[air1.volume]kPa)","Flow Rate Control",src.set_flow_rate) as num
|
||||
src.set_flow_rate = between(0, new_flow_rate, air1.volume)
|
||||
|
||||
usr.set_machine(src) //Is this even needed with NanoUI?
|
||||
src.update_icon()
|
||||
src.add_fingerprint(usr)
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/attackby(var/obj/item/W as obj, var/mob/user as mob)
|
||||
if (!W.iswrench())
|
||||
return ..()
|
||||
if (unlocked)
|
||||
to_chat(user, "<span class='warning'>You cannot unwrench \the [src], turn it off first.</span>")
|
||||
return 1
|
||||
var/datum/gas_mixture/int_air = return_air()
|
||||
var/datum/gas_mixture/env_air = loc.return_air()
|
||||
if ((int_air.return_pressure()-env_air.return_pressure()) > 2*ONE_ATMOSPHERE)
|
||||
to_chat(user, "<span class='warning'>You cannot unwrench \the [src], it too exerted due to internal pressure.</span>")
|
||||
add_fingerprint(user)
|
||||
return 1
|
||||
playsound(src.loc, W.usesound, 50, 1)
|
||||
to_chat(user, "<span class='notice'>You begin to unfasten \the [src]...</span>")
|
||||
if (do_after(user, 40/W.toolspeed, act_target = src))
|
||||
user.visible_message( \
|
||||
"<span class='notice'>\The [user] unfastens \the [src].</span>", \
|
||||
"<span class='notice'>You have unfastened \the [src].</span>", \
|
||||
"You hear ratchet.")
|
||||
new /obj/item/pipe(loc, make_from=src)
|
||||
qdel(src)
|
||||
|
||||
#undef REGULATE_NONE
|
||||
#undef REGULATE_INPUT
|
||||
#undef REGULATE_OUTPUT
|
||||
#define REGULATE_NONE 0
|
||||
#define REGULATE_INPUT 1 //shuts off when input side is below the target pressure
|
||||
#define REGULATE_OUTPUT 2 //shuts off when output side is above the target pressure
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate
|
||||
icon = 'icons/atmos/passive_gate.dmi'
|
||||
icon_state = "map"
|
||||
level = 1
|
||||
|
||||
name = "pressure regulator"
|
||||
desc = "A one-way air valve that can be used to regulate input or output pressure, and flow rate. Does not require power."
|
||||
|
||||
use_power = 0
|
||||
interact_offline = 1
|
||||
var/unlocked = 0 //If 0, then the valve is locked closed, otherwise it is open(-able, it's a one-way valve so it closes if gas would flow backwards).
|
||||
var/target_pressure = ONE_ATMOSPHERE
|
||||
var/max_pressure_setting = 15000 //kPa
|
||||
var/set_flow_rate = ATMOS_DEFAULT_VOLUME_PUMP * 2.5
|
||||
var/regulate_mode = REGULATE_OUTPUT
|
||||
|
||||
var/flowing = 0 //for icons - becomes zero if the valve closes itself due to regulation mode
|
||||
|
||||
var/frequency = 0
|
||||
var/id = null
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/Initialize()
|
||||
. = ..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP * 2.5
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP * 2.5
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/update_icon()
|
||||
icon_state = (unlocked && flowing)? "on" : "off"
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/update_underlays()
|
||||
if(..())
|
||||
underlays.Cut()
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
add_underlay(T, node1, turn(dir, 180))
|
||||
add_underlay(T, node2, dir)
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/hide(var/i)
|
||||
update_underlays()
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/machinery_process()
|
||||
..()
|
||||
|
||||
last_flow_rate = 0
|
||||
|
||||
if(!unlocked)
|
||||
return 0
|
||||
|
||||
var/output_starting_pressure = air2.return_pressure()
|
||||
var/input_starting_pressure = air1.return_pressure()
|
||||
|
||||
var/pressure_delta
|
||||
switch (regulate_mode)
|
||||
if (REGULATE_INPUT)
|
||||
pressure_delta = input_starting_pressure - target_pressure
|
||||
if (REGULATE_OUTPUT)
|
||||
pressure_delta = target_pressure - output_starting_pressure
|
||||
|
||||
//-1 if pump_gas() did not move any gas, >= 0 otherwise
|
||||
var/returnval = -1
|
||||
if((regulate_mode == REGULATE_NONE || pressure_delta > 0.01) && (air1.temperature > 0 || air2.temperature > 0)) //since it's basically a valve, it makes sense to check both temperatures
|
||||
flowing = 1
|
||||
|
||||
//flow rate limit
|
||||
var/transfer_moles = (set_flow_rate/air1.volume)*air1.total_moles
|
||||
|
||||
//Figure out how much gas to transfer to meet the target pressure.
|
||||
switch (regulate_mode)
|
||||
if (REGULATE_INPUT)
|
||||
transfer_moles = min(transfer_moles, calculate_transfer_moles(air2, air1, pressure_delta, (network1)? network1.volume : 0))
|
||||
if (REGULATE_OUTPUT)
|
||||
transfer_moles = min(transfer_moles, calculate_transfer_moles(air1, air2, pressure_delta, (network2)? network2.volume : 0))
|
||||
|
||||
//pump_gas() will return a negative number if no flow occurred
|
||||
returnval = pump_gas_passive(src, air1, air2, transfer_moles)
|
||||
|
||||
if (returnval >= 0)
|
||||
if(network1)
|
||||
network1.update = 1
|
||||
|
||||
if(network2)
|
||||
network2.update = 1
|
||||
|
||||
if (last_flow_rate)
|
||||
flowing = 1
|
||||
|
||||
update_icon()
|
||||
|
||||
|
||||
//Radio remote control
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/proc/set_frequency(new_frequency)
|
||||
SSradio.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/proc/broadcast_status()
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = 1 //radio signal
|
||||
signal.source = src
|
||||
|
||||
signal.data = list(
|
||||
"tag" = id,
|
||||
"device" = "AGP",
|
||||
"power" = unlocked,
|
||||
"target_output" = target_pressure,
|
||||
"regulate_mode" = regulate_mode,
|
||||
"set_flow_rate" = set_flow_rate,
|
||||
"sigtype" = "status"
|
||||
)
|
||||
|
||||
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/atmos_init()
|
||||
..()
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/receive_signal(datum/signal/signal)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
|
||||
if("power" in signal.data)
|
||||
unlocked = text2num(signal.data["power"])
|
||||
|
||||
if("power_toggle" in signal.data)
|
||||
unlocked = !unlocked
|
||||
|
||||
if("set_target_pressure" in signal.data)
|
||||
target_pressure = between(
|
||||
0,
|
||||
text2num(signal.data["set_target_pressure"]),
|
||||
max_pressure_setting
|
||||
)
|
||||
|
||||
if("set_regulate_mode" in signal.data)
|
||||
regulate_mode = text2num(signal.data["set_regulate_mode"])
|
||||
|
||||
if("set_flow_rate" in signal.data)
|
||||
regulate_mode = text2num(signal.data["set_flow_rate"])
|
||||
|
||||
if("status" in signal.data)
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
return //do not update_icon
|
||||
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
update_icon()
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/attack_hand(user as mob)
|
||||
if(..())
|
||||
return
|
||||
src.add_fingerprint(usr)
|
||||
if(!src.allowed(user))
|
||||
to_chat(user, "<span class='warning'>Access denied.</span>")
|
||||
return
|
||||
usr.set_machine(src)
|
||||
ui_interact(user)
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1)
|
||||
if(stat & (BROKEN|NOPOWER))
|
||||
return
|
||||
|
||||
// this is the data which will be sent to the ui
|
||||
var/data[0]
|
||||
|
||||
data = list(
|
||||
"on" = unlocked,
|
||||
"pressure_set" = round(target_pressure*100), //Nano UI can't handle rounded non-integers, apparently.
|
||||
"max_pressure" = max_pressure_setting,
|
||||
"input_pressure" = round(air1.return_pressure()*100),
|
||||
"output_pressure" = round(air2.return_pressure()*100),
|
||||
"regulate_mode" = regulate_mode,
|
||||
"set_flow_rate" = round(set_flow_rate*10),
|
||||
"last_flow_rate" = round(last_flow_rate*10)
|
||||
)
|
||||
|
||||
// update the ui if it exists, returns null if no ui is passed/found
|
||||
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, data, force_open)
|
||||
if (!ui)
|
||||
// the ui does not exist, so we'll create a new() one
|
||||
// for a list of parameters and their descriptions see the code docs in \code\modules\nano\nanoui.dm
|
||||
ui = new(user, src, ui_key, "pressure_regulator.tmpl", name, 470, 370)
|
||||
ui.set_initial_data(data) // when the ui is first opened this is the data it will use
|
||||
ui.open() // open the new ui window
|
||||
ui.set_auto_update(1) // auto update every Master Controller tick
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/Topic(href,href_list)
|
||||
if(..()) return 1
|
||||
|
||||
if(href_list["toggle_valve"])
|
||||
unlocked = !unlocked
|
||||
|
||||
if(href_list["regulate_mode"])
|
||||
switch(href_list["regulate_mode"])
|
||||
if ("off") regulate_mode = REGULATE_NONE
|
||||
if ("input") regulate_mode = REGULATE_INPUT
|
||||
if ("output") regulate_mode = REGULATE_OUTPUT
|
||||
|
||||
switch(href_list["set_press"])
|
||||
if ("min")
|
||||
target_pressure = 0
|
||||
if ("max")
|
||||
target_pressure = max_pressure_setting
|
||||
if ("set")
|
||||
var/new_pressure = input(usr,"Enter new output pressure (0-[max_pressure_setting]kPa)","Pressure Control",src.target_pressure) as num
|
||||
src.target_pressure = between(0, new_pressure, max_pressure_setting)
|
||||
|
||||
switch(href_list["set_flow_rate"])
|
||||
if ("min")
|
||||
set_flow_rate = 0
|
||||
if ("max")
|
||||
set_flow_rate = air1.volume
|
||||
if ("set")
|
||||
var/new_flow_rate = input(usr,"Enter new flow rate limit (0-[air1.volume]kPa)","Flow Rate Control",src.set_flow_rate) as num
|
||||
src.set_flow_rate = between(0, new_flow_rate, air1.volume)
|
||||
|
||||
usr.set_machine(src) //Is this even needed with NanoUI?
|
||||
src.update_icon()
|
||||
src.add_fingerprint(usr)
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/passive_gate/attackby(var/obj/item/W as obj, var/mob/user as mob)
|
||||
if (!W.iswrench())
|
||||
return ..()
|
||||
if (unlocked)
|
||||
to_chat(user, "<span class='warning'>You cannot unwrench \the [src], turn it off first.</span>")
|
||||
return 1
|
||||
var/datum/gas_mixture/int_air = return_air()
|
||||
var/datum/gas_mixture/env_air = loc.return_air()
|
||||
if ((int_air.return_pressure()-env_air.return_pressure()) > 2*ONE_ATMOSPHERE)
|
||||
to_chat(user, "<span class='warning'>You cannot unwrench \the [src], it too exerted due to internal pressure.</span>")
|
||||
add_fingerprint(user)
|
||||
return 1
|
||||
playsound(src.loc, W.usesound, 50, 1)
|
||||
to_chat(user, "<span class='notice'>You begin to unfasten \the [src]...</span>")
|
||||
if (do_after(user, 40/W.toolspeed, act_target = src))
|
||||
user.visible_message( \
|
||||
"<span class='notice'>\The [user] unfastens \the [src].</span>", \
|
||||
"<span class='notice'>You have unfastened \the [src].</span>", \
|
||||
"You hear ratchet.")
|
||||
new /obj/item/pipe(loc, make_from=src)
|
||||
qdel(src)
|
||||
|
||||
#undef REGULATE_NONE
|
||||
#undef REGULATE_INPUT
|
||||
#undef REGULATE_OUTPUT
|
||||
|
||||
@@ -1,238 +1,238 @@
|
||||
/*
|
||||
Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
|
||||
|
||||
node1, air1, network1 correspond to input
|
||||
node2, air2, network2 correspond to output
|
||||
|
||||
Thus, the two variables affect pump operation are set in New():
|
||||
air1.volume
|
||||
This is the volume of gas available to the pump that may be transfered to the output
|
||||
air2.volume
|
||||
Higher quantities of this cause more air to be perfected later
|
||||
but overall network volume is also increased as this increases...
|
||||
*/
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump
|
||||
icon = 'icons/atmos/pump.dmi'
|
||||
icon_state = "map_off"
|
||||
level = 1
|
||||
|
||||
name = "gas pump"
|
||||
desc = "A pump"
|
||||
|
||||
var/target_pressure = ONE_ATMOSPHERE
|
||||
|
||||
//var/max_volume_transfer = 10000
|
||||
|
||||
use_power = 0
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //7500 W ~ 10 HP
|
||||
|
||||
var/max_pressure_setting = 15000 //kPa
|
||||
|
||||
var/frequency = 0
|
||||
var/id = null
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/Initialize()
|
||||
. = ..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/on
|
||||
icon_state = "map_on"
|
||||
use_power = 1
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/update_icon()
|
||||
if(!powered())
|
||||
icon_state = "off"
|
||||
else
|
||||
icon_state = "[use_power ? "on" : "off"]"
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/update_underlays()
|
||||
if(..())
|
||||
underlays.Cut()
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
add_underlay(T, node1, turn(dir, -180))
|
||||
add_underlay(T, node2, dir)
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/hide(var/i)
|
||||
update_underlays()
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/machinery_process()
|
||||
last_power_draw = 0
|
||||
last_flow_rate = 0
|
||||
|
||||
if((stat & (NOPOWER|BROKEN)) || !use_power)
|
||||
return
|
||||
|
||||
var/power_draw = -1
|
||||
var/pressure_delta = target_pressure - air2.return_pressure()
|
||||
|
||||
if(pressure_delta > 0.01 && air1.temperature > 0)
|
||||
//Figure out how much gas to transfer to meet the target pressure.
|
||||
var/transfer_moles = calculate_transfer_moles(air1, air2, pressure_delta, (network2)? network2.volume : 0)
|
||||
power_draw = pump_gas(src, air1, air2, transfer_moles, power_rating)
|
||||
|
||||
if (power_draw >= 0)
|
||||
last_power_draw = power_draw
|
||||
use_power(power_draw)
|
||||
|
||||
if(network1)
|
||||
network1.update = 1
|
||||
|
||||
if(network2)
|
||||
network2.update = 1
|
||||
|
||||
return 1
|
||||
|
||||
//Radio remote control
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/proc/set_frequency(new_frequency)
|
||||
SSradio.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/proc/broadcast_status()
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = 1 //radio signal
|
||||
signal.source = src
|
||||
|
||||
signal.data = list(
|
||||
"tag" = id,
|
||||
"device" = "AGP",
|
||||
"power" = use_power,
|
||||
"target_output" = target_pressure,
|
||||
"sigtype" = "status"
|
||||
)
|
||||
|
||||
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1)
|
||||
if(stat & (BROKEN|NOPOWER))
|
||||
return
|
||||
|
||||
// this is the data which will be sent to the ui
|
||||
var/data[0]
|
||||
|
||||
data = list(
|
||||
"on" = use_power,
|
||||
"pressure_set" = round(target_pressure*100), //Nano UI can't handle rounded non-integers, apparently.
|
||||
"max_pressure" = max_pressure_setting,
|
||||
"last_flow_rate" = round(last_flow_rate*10),
|
||||
"last_power_draw" = round(last_power_draw),
|
||||
"max_power_draw" = power_rating
|
||||
)
|
||||
|
||||
// update the ui if it exists, returns null if no ui is passed/found
|
||||
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, data, force_open)
|
||||
if (!ui)
|
||||
// the ui does not exist, so we'll create a new() one
|
||||
// for a list of parameters and their descriptions see the code docs in \code\modules\nano\nanoui.dm
|
||||
ui = new(user, src, ui_key, "gas_pump.tmpl", name, 470, 290)
|
||||
ui.set_initial_data(data) // when the ui is first opened this is the data it will use
|
||||
ui.open() // open the new ui window
|
||||
ui.set_auto_update(1) // auto update every Master Controller tick
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/atmos_init()
|
||||
..()
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/receive_signal(datum/signal/signal)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
|
||||
if(signal.data["power"])
|
||||
if(text2num(signal.data["power"]))
|
||||
use_power = 1
|
||||
else
|
||||
use_power = 0
|
||||
|
||||
if("power_toggle" in signal.data)
|
||||
use_power = !use_power
|
||||
|
||||
if(signal.data["set_output_pressure"])
|
||||
target_pressure = between(
|
||||
0,
|
||||
text2num(signal.data["set_output_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["status"])
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
return //do not update_icon
|
||||
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
update_icon()
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/attack_hand(user as mob)
|
||||
if(..())
|
||||
return
|
||||
src.add_fingerprint(usr)
|
||||
if(!src.allowed(user))
|
||||
to_chat(user, "<span class='warning'>Access denied.</span>")
|
||||
return
|
||||
usr.set_machine(src)
|
||||
ui_interact(user)
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/Topic(href,href_list)
|
||||
if(..()) return 1
|
||||
|
||||
if(href_list["power"])
|
||||
use_power = !use_power
|
||||
|
||||
switch(href_list["set_press"])
|
||||
if ("min")
|
||||
target_pressure = 0
|
||||
if ("max")
|
||||
target_pressure = max_pressure_setting
|
||||
if ("set")
|
||||
var/new_pressure = input(usr,"Enter new output pressure (0-[max_pressure_setting]kPa)","Pressure control",src.target_pressure) as num
|
||||
src.target_pressure = between(0, new_pressure, max_pressure_setting)
|
||||
|
||||
usr.set_machine(src)
|
||||
src.add_fingerprint(usr)
|
||||
|
||||
src.update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/power_change()
|
||||
var/old_stat = stat
|
||||
..()
|
||||
if(old_stat != stat)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/attackby(var/obj/item/W as obj, var/mob/user as mob)
|
||||
if (!W.iswrench() && !istype(W, /obj/item/pipewrench))
|
||||
return ..()
|
||||
if (!(stat & NOPOWER) && use_power)
|
||||
to_chat(user, "<span class='warning'>You cannot unwrench this [src], turn it off first.</span>")
|
||||
return 1
|
||||
var/datum/gas_mixture/int_air = return_air()
|
||||
var/datum/gas_mixture/env_air = loc.return_air()
|
||||
if ((int_air.return_pressure()-env_air.return_pressure()) > 2*ONE_ATMOSPHERE && !istype(W, /obj/item/pipewrench))
|
||||
to_chat(user, "<span class='warning'>You cannot unwrench this [src], it's too exerted due to internal pressure.</span>")
|
||||
add_fingerprint(user)
|
||||
return 1
|
||||
else
|
||||
to_chat(user, "<span class='warning'>You struggle to unwrench \the [src] with your pipe wrench.</span>")
|
||||
playsound(src.loc, W.usesound, 50, 1)
|
||||
to_chat(user, "<span class='notice'>You begin to unfasten \the [src]...</span>")
|
||||
if (do_after(user, istype(W, /obj/item/pipewrench) ? 80/W.toolspeed : 40/W.toolspeed, act_target = src))
|
||||
user.visible_message( \
|
||||
"<span class='notice'>\The [user] unfastens \the [src].</span>", \
|
||||
"<span class='notice'>You have unfastened \the [src].</span>", \
|
||||
"You hear a ratchet.")
|
||||
new /obj/item/pipe(loc, make_from=src)
|
||||
qdel(src)
|
||||
/*
|
||||
Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
|
||||
|
||||
node1, air1, network1 correspond to input
|
||||
node2, air2, network2 correspond to output
|
||||
|
||||
Thus, the two variables affect pump operation are set in New():
|
||||
air1.volume
|
||||
This is the volume of gas available to the pump that may be transfered to the output
|
||||
air2.volume
|
||||
Higher quantities of this cause more air to be perfected later
|
||||
but overall network volume is also increased as this increases...
|
||||
*/
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump
|
||||
icon = 'icons/atmos/pump.dmi'
|
||||
icon_state = "map_off"
|
||||
level = 1
|
||||
|
||||
name = "gas pump"
|
||||
desc = "A pump"
|
||||
|
||||
var/target_pressure = ONE_ATMOSPHERE
|
||||
|
||||
//var/max_volume_transfer = 10000
|
||||
|
||||
use_power = 0
|
||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||
power_rating = 7500 //7500 W ~ 10 HP
|
||||
|
||||
var/max_pressure_setting = 15000 //kPa
|
||||
|
||||
var/frequency = 0
|
||||
var/id = null
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/Initialize()
|
||||
. = ..()
|
||||
air1.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/on
|
||||
icon_state = "map_on"
|
||||
use_power = 1
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/update_icon()
|
||||
if(!powered())
|
||||
icon_state = "off"
|
||||
else
|
||||
icon_state = "[use_power ? "on" : "off"]"
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/update_underlays()
|
||||
if(..())
|
||||
underlays.Cut()
|
||||
var/turf/T = get_turf(src)
|
||||
if(!istype(T))
|
||||
return
|
||||
add_underlay(T, node1, turn(dir, -180))
|
||||
add_underlay(T, node2, dir)
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/hide(var/i)
|
||||
update_underlays()
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/machinery_process()
|
||||
last_power_draw = 0
|
||||
last_flow_rate = 0
|
||||
|
||||
if((stat & (NOPOWER|BROKEN)) || !use_power)
|
||||
return
|
||||
|
||||
var/power_draw = -1
|
||||
var/pressure_delta = target_pressure - air2.return_pressure()
|
||||
|
||||
if(pressure_delta > 0.01 && air1.temperature > 0)
|
||||
//Figure out how much gas to transfer to meet the target pressure.
|
||||
var/transfer_moles = calculate_transfer_moles(air1, air2, pressure_delta, (network2)? network2.volume : 0)
|
||||
power_draw = pump_gas(src, air1, air2, transfer_moles, power_rating)
|
||||
|
||||
if (power_draw >= 0)
|
||||
last_power_draw = power_draw
|
||||
use_power(power_draw)
|
||||
|
||||
if(network1)
|
||||
network1.update = 1
|
||||
|
||||
if(network2)
|
||||
network2.update = 1
|
||||
|
||||
return 1
|
||||
|
||||
//Radio remote control
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/proc/set_frequency(new_frequency)
|
||||
SSradio.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
if(frequency)
|
||||
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/proc/broadcast_status()
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = 1 //radio signal
|
||||
signal.source = src
|
||||
|
||||
signal.data = list(
|
||||
"tag" = id,
|
||||
"device" = "AGP",
|
||||
"power" = use_power,
|
||||
"target_output" = target_pressure,
|
||||
"sigtype" = "status"
|
||||
)
|
||||
|
||||
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1)
|
||||
if(stat & (BROKEN|NOPOWER))
|
||||
return
|
||||
|
||||
// this is the data which will be sent to the ui
|
||||
var/data[0]
|
||||
|
||||
data = list(
|
||||
"on" = use_power,
|
||||
"pressure_set" = round(target_pressure*100), //Nano UI can't handle rounded non-integers, apparently.
|
||||
"max_pressure" = max_pressure_setting,
|
||||
"last_flow_rate" = round(last_flow_rate*10),
|
||||
"last_power_draw" = round(last_power_draw),
|
||||
"max_power_draw" = power_rating
|
||||
)
|
||||
|
||||
// update the ui if it exists, returns null if no ui is passed/found
|
||||
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, data, force_open)
|
||||
if (!ui)
|
||||
// the ui does not exist, so we'll create a new() one
|
||||
// for a list of parameters and their descriptions see the code docs in \code\modules\nano\nanoui.dm
|
||||
ui = new(user, src, ui_key, "gas_pump.tmpl", name, 470, 290)
|
||||
ui.set_initial_data(data) // when the ui is first opened this is the data it will use
|
||||
ui.open() // open the new ui window
|
||||
ui.set_auto_update(1) // auto update every Master Controller tick
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/atmos_init()
|
||||
..()
|
||||
if(frequency)
|
||||
set_frequency(frequency)
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/receive_signal(datum/signal/signal)
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
|
||||
if(signal.data["power"])
|
||||
if(text2num(signal.data["power"]))
|
||||
use_power = 1
|
||||
else
|
||||
use_power = 0
|
||||
|
||||
if("power_toggle" in signal.data)
|
||||
use_power = !use_power
|
||||
|
||||
if(signal.data["set_output_pressure"])
|
||||
target_pressure = between(
|
||||
0,
|
||||
text2num(signal.data["set_output_pressure"]),
|
||||
ONE_ATMOSPHERE*50
|
||||
)
|
||||
|
||||
if(signal.data["status"])
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
return //do not update_icon
|
||||
|
||||
addtimer(CALLBACK(src, .proc/broadcast_status), 2, TIMER_UNIQUE)
|
||||
update_icon()
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/attack_hand(user as mob)
|
||||
if(..())
|
||||
return
|
||||
src.add_fingerprint(usr)
|
||||
if(!src.allowed(user))
|
||||
to_chat(user, "<span class='warning'>Access denied.</span>")
|
||||
return
|
||||
usr.set_machine(src)
|
||||
ui_interact(user)
|
||||
return
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/Topic(href,href_list)
|
||||
if(..()) return 1
|
||||
|
||||
if(href_list["power"])
|
||||
use_power = !use_power
|
||||
|
||||
switch(href_list["set_press"])
|
||||
if ("min")
|
||||
target_pressure = 0
|
||||
if ("max")
|
||||
target_pressure = max_pressure_setting
|
||||
if ("set")
|
||||
var/new_pressure = input(usr,"Enter new output pressure (0-[max_pressure_setting]kPa)","Pressure control",src.target_pressure) as num
|
||||
src.target_pressure = between(0, new_pressure, max_pressure_setting)
|
||||
|
||||
usr.set_machine(src)
|
||||
src.add_fingerprint(usr)
|
||||
|
||||
src.update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/power_change()
|
||||
var/old_stat = stat
|
||||
..()
|
||||
if(old_stat != stat)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/attackby(var/obj/item/W as obj, var/mob/user as mob)
|
||||
if (!W.iswrench() && !istype(W, /obj/item/pipewrench))
|
||||
return ..()
|
||||
if (!(stat & NOPOWER) && use_power)
|
||||
to_chat(user, "<span class='warning'>You cannot unwrench this [src], turn it off first.</span>")
|
||||
return 1
|
||||
var/datum/gas_mixture/int_air = return_air()
|
||||
var/datum/gas_mixture/env_air = loc.return_air()
|
||||
if ((int_air.return_pressure()-env_air.return_pressure()) > 2*ONE_ATMOSPHERE && !istype(W, /obj/item/pipewrench))
|
||||
to_chat(user, "<span class='warning'>You cannot unwrench this [src], it's too exerted due to internal pressure.</span>")
|
||||
add_fingerprint(user)
|
||||
return 1
|
||||
else
|
||||
to_chat(user, "<span class='warning'>You struggle to unwrench \the [src] with your pipe wrench.</span>")
|
||||
playsound(src.loc, W.usesound, 50, 1)
|
||||
to_chat(user, "<span class='notice'>You begin to unfasten \the [src]...</span>")
|
||||
if (do_after(user, istype(W, /obj/item/pipewrench) ? 80/W.toolspeed : 40/W.toolspeed, act_target = src))
|
||||
user.visible_message( \
|
||||
"<span class='notice'>\The [user] unfastens \the [src].</span>", \
|
||||
"<span class='notice'>You have unfastened \the [src].</span>", \
|
||||
"You hear a ratchet.")
|
||||
new /obj/item/pipe(loc, make_from=src)
|
||||
qdel(src)
|
||||
|
||||
@@ -1,19 +1,19 @@
|
||||
/obj/machinery/atmospherics/binary/pump/high_power
|
||||
icon = 'icons/atmos/volume_pump.dmi'
|
||||
icon_state = "map_off"
|
||||
level = 1
|
||||
|
||||
name = "high power gas pump"
|
||||
desc = "A pump. Has double the power rating of the standard gas pump."
|
||||
|
||||
power_rating = 15000 //15000 W ~ 20 HP
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/high_power/on
|
||||
use_power = 1
|
||||
icon_state = "map_on"
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/high_power/update_icon()
|
||||
if(!powered())
|
||||
icon_state = "off"
|
||||
else
|
||||
/obj/machinery/atmospherics/binary/pump/high_power
|
||||
icon = 'icons/atmos/volume_pump.dmi'
|
||||
icon_state = "map_off"
|
||||
level = 1
|
||||
|
||||
name = "high power gas pump"
|
||||
desc = "A pump. Has double the power rating of the standard gas pump."
|
||||
|
||||
power_rating = 15000 //15000 W ~ 20 HP
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/high_power/on
|
||||
use_power = 1
|
||||
icon_state = "map_on"
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/high_power/update_icon()
|
||||
if(!powered())
|
||||
icon_state = "off"
|
||||
else
|
||||
icon_state = "[use_power ? "on" : "off"]"
|
||||
Reference in New Issue
Block a user