Atmos machine update

Takes a pass at updating ATMOSPHERICS to take advantage of the new powernet changes.

Also removes var/on definitions from many atmos machines. Machines generally shouldn't
be doing "on" things if they aren't using power, and most players don't expect a machine
to use power if it isn't "on," so I guess this is fair game.

Also, further refactoring.
This commit is contained in:
mwerezak
2015-01-02 01:46:18 -05:00
parent 73f9617cef
commit f9344a5a2d
25 changed files with 729 additions and 823 deletions
@@ -22,14 +22,12 @@
level = 1
use_power = 1
use_power = 0
idle_power_usage = 150 //internal circuitry, friction losses and stuff
active_power_usage = 7500 //This also doubles as a measure of how powerful the pump is, in Watts. 7500 W ~ 10 HP
var/last_power_draw = 0
power_rating = 7500 //7500 W ~ 10 HP
connect_types = CONNECT_TYPE_REGULAR|CONNECT_TYPE_SUPPLY|CONNECT_TYPE_SCRUBBER //connects to regular, supply and scrubbers pipes
var/on = 0
var/pump_direction = 1 //0 = siphoning, 1 = releasing
var/external_pressure_bound = EXTERNAL_PRESSURE_BOUND
@@ -77,7 +75,7 @@
if(!powered())
vent_icon += "off"
else
vent_icon += "[on ? "[pump_direction ? "out" : "in"]" : "off"]"
vent_icon += "[use_power ? "[pump_direction ? "out" : "in"]" : "off"]"
overlays += icon_manager.get_atmos_icon("device", , , vent_icon)
@@ -106,10 +104,10 @@
/obj/machinery/atmospherics/binary/dp_vent_pump/process()
..()
if(stat & (NOPOWER|BROKEN) || !on)
update_use_power(0) //usually we get here because a player turned a pump off - definitely want to update.
last_power_draw = 0
last_flow_rate = 0
last_power_draw = 0
last_flow_rate = 0
if(stat & (NOPOWER|BROKEN) || !use_power)
return 0
var/datum/gas_mixture/environment = loc.return_air()
@@ -122,35 +120,25 @@
if(pressure_delta > 0.5)
if(pump_direction) //internal -> external
if (node1 && (environment.temperature || air1.temperature))
var/output_volume = environment.volume * environment.group_multiplier
var/air_temperature = environment.temperature? environment.temperature : air1.temperature
var/transfer_moles = pressure_delta*output_volume/(air_temperature * R_IDEAL_GAS_EQUATION)
power_draw = pump_gas(src, air1, environment, transfer_moles, active_power_usage)
var/transfer_moles = calculate_transfer_moles(air1, environment)
power_draw = pump_gas(src, air1, environment, transfer_moles, power_rating)
if(power_draw >= 0 && network1)
network1.update = 1
else //external -> internal
if (node2 && (environment.temperature || air2.temperature))
var/output_volume = air2.volume + (network2? network2.volume : 0)
var/air_temperature = air2.temperature? air2.temperature : environment.temperature
var/transfer_moles = pressure_delta*output_volume/(air_temperature * R_IDEAL_GAS_EQUATION)
var/transfer_moles = calculate_transfer_moles(environment, air2, (network2)? network2.volume : 0)
//limit flow rate from turfs
transfer_moles = min(transfer_moles, environment.total_moles*air2.volume/environment.volume) //group_multiplier gets divided out here
power_draw = pump_gas(src, environment, air2, transfer_moles, active_power_usage)
power_draw = pump_gas(src, environment, air2, transfer_moles, power_rating)
if(power_draw >= 0 && network2)
network2.update = 1
if (power_draw < 0)
last_power_draw = 0
last_flow_rate = 0
//update_use_power(0)
use_power = 0 //don't force update - easier on CPU
else
last_power_draw = handle_power_draw(power_draw)
if (power_draw >= 0)
last_power_draw = power_draw
use_power(power_draw)
return 1
@@ -191,7 +179,7 @@
signal.data = list(
"tag" = id,
"device" = "ADVP",
"power" = on,
"power" = use_power,
"direction" = pump_direction?("release"):("siphon"),
"checks" = pressure_checks,
"input" = input_pressure_min,
@@ -223,10 +211,10 @@
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
if(signal.data["power"])
on = text2num(signal.data["power"])
use_power = text2num(signal.data["power"])
if(signal.data["power_toggle"])
on = !on
use_power = !use_power
if(signal.data["direction"])
pump_direction = text2num(signal.data["direction"])