Re-creation of https://github.com/Aurorastation/Aurora.3/pull/21046 to skip merge conflict hell. Brings us modern TGUI. **ALTERNATE TITLE: TGUI HELLSCAPE PR ABANDON ALL HOPE YE WHO ENTER HERE** - [x] Migrate build tools (javascript -> typescript, bun for package management). - [x] Upgrade all TGUI dependencies and associated root files to TG-congruent versions (axios, babel, dompurify, eslint, highlight, marked, prettier, sass, source-map, stacktrace-parser, typescript). - [x] InfernoJS -> React migrations - [x] React cleanup and polish (migrate all remaining .js files to appropriate .ts or .tsx filetype, all remaining hooks, linting, error corrections, etc.) - [ ] Test all remaining TGUI interfaces
78 lines
2.2 KiB
Plaintext
78 lines
2.2 KiB
Plaintext
SUBSYSTEM_DEF(nightlight)
|
|
name = "Night Lighting"
|
|
wait = 5 MINUTES
|
|
init_order = SS_INIT_NIGHT
|
|
flags = SS_BACKGROUND | SS_NO_FIRE
|
|
priority = SS_PRIORITY_NIGHT
|
|
|
|
var/isactive = FALSE
|
|
var/disable_type = NL_NOT_DISABLED
|
|
|
|
/datum/controller/subsystem/nightlight/Initialize(start_timeofday)
|
|
return SS_INIT_SUCCESS
|
|
|
|
/datum/controller/subsystem/nightlight/stat_entry(msg)
|
|
msg = "A:[isactive] T:[worldtime2hours()] D:[disable_type]"
|
|
return ..()
|
|
|
|
/datum/controller/subsystem/nightlight/Recover()
|
|
src.isactive = SSnightlight.isactive
|
|
src.disable_type = SSnightlight.disable_type
|
|
|
|
/datum/controller/subsystem/nightlight/proc/temp_disable(time = -1)
|
|
if (disable_type != NL_PERMANENT_DISABLE)
|
|
disable_type = NL_TEMPORARY_DISABLE
|
|
can_fire = FALSE
|
|
deactivate(FALSE)
|
|
if (time > 0)
|
|
addtimer(CALLBACK(src, PROC_REF(end_temp_disable)), time, TIMER_UNIQUE | TIMER_OVERRIDE)
|
|
|
|
/datum/controller/subsystem/nightlight/proc/end_temp_disable()
|
|
if (disable_type == NL_TEMPORARY_DISABLE)
|
|
can_fire = TRUE
|
|
|
|
// 'whitelisted' areas are areas that have nightmode explicitly enabled
|
|
|
|
/datum/controller/subsystem/nightlight/proc/activate(var/whitelisted_only = 1)
|
|
isactive = 1
|
|
for (var/obj/structure/machinery/power/apc/APC in get_apc_list(whitelisted_only))
|
|
APC.toggle_nightlight("on")
|
|
|
|
CHECK_TICK
|
|
|
|
/datum/controller/subsystem/nightlight/proc/deactivate(var/whitelisted_only = 1)
|
|
isactive = 0
|
|
for (var/obj/structure/machinery/power/apc/APC in get_apc_list(whitelisted_only))
|
|
APC.toggle_nightlight("off")
|
|
|
|
CHECK_TICK
|
|
|
|
/datum/controller/subsystem/nightlight/proc/get_apc_list(var/whitelisted_only = 1)
|
|
var/list/obj/structure/machinery/power/apc/lighting_apcs = list()
|
|
|
|
for (var/obj/structure/machinery/power/apc/APC in SSmachinery.apc_units)
|
|
if (QDELETED(APC) || APC.aidisabled)
|
|
continue
|
|
|
|
var/area/apc_area = APC.area || get_area(APC)
|
|
if (!apc_area)
|
|
continue
|
|
if (apc_area.no_light_control || (!(apc_area.allow_nightmode) && whitelisted_only))
|
|
continue
|
|
lighting_apcs += APC
|
|
|
|
CHECK_TICK
|
|
|
|
return lighting_apcs
|
|
|
|
/datum/controller/subsystem/nightlight/proc/is_active()
|
|
return isactive
|
|
|
|
// /datum/controller/subsystem/nightlight/enable()
|
|
// ..()
|
|
// disable_type = NL_NOT_DISABLED
|
|
|
|
// /datum/controller/subsystem/nightlight/disable()
|
|
// ..()
|
|
// disable_type = NL_PERMANENT_DISABLE
|