var/datum/controller/process/night_lighting/nl_ctrl
|
|
|
|
/datum/controller/process/night_lighting/
|
|
var/isactive = 0
|
|
var/firstrun = 1
|
|
var/manual_override = 0
|
|
|
|
/datum/controller/process/night_lighting/proc/is_active()
|
|
return isactive
|
|
|
|
/datum/controller/process/night_lighting/setup()
|
|
name = "night lighting controller"
|
|
schedule_interval = 5 MINUTES
|
|
|
|
nl_ctrl = src
|
|
|
|
if (!config.night_lighting)
|
|
// Stop trying to delete processes. Not how it goes.
|
|
disabled = 1
|
|
|
|
/datum/controller/process/night_lighting/preStart()
|
|
var/time = worldtime2hours()
|
|
if (time <= config.nl_finish || time >= config.nl_start)
|
|
activate()
|
|
else
|
|
deactivate()
|
|
|
|
/datum/controller/process/night_lighting/doWork()
|
|
if (manual_override) // don't automatically change lighting if it was manually changed in-game
|
|
return
|
|
|
|
var/time = worldtime2hours()
|
|
if (time <= config.nl_finish || time >= config.nl_start)
|
|
if (!isactive)
|
|
command_announcement.Announce("Good evening. The time is [worldtime2text()]. \n\nThe automated systems aboard the [station_name()] will now dim lighting in the public hallways in order to accommodate the circadian rhythm of some species.", "Automated Lighting System", new_sound = 'sound/misc/bosuns_whistle.ogg')
|
|
activate()
|
|
else
|
|
if (isactive)
|
|
command_announcement.Announce("Good morning. The time is [worldtime2text()]. \n\nThe automated systems aboard the [station_name()] will now return the public hallway lighting levels to normal.", "Automated Lighting System", new_sound = 'sound/misc/bosuns_whistle.ogg')
|
|
deactivate()
|
|
|
|
// 'whitelisted' areas are areas that have nightmode explicitly enabled
|
|
|
|
/datum/controller/process/night_lighting/proc/activate(var/whitelisted_only = 1)
|
|
isactive = 1
|
|
for (var/obj/machinery/power/apc/APC in get_apc_list(whitelisted_only))
|
|
APC.toggle_nightlight("on")
|
|
|
|
F_SCHECK
|
|
|
|
/datum/controller/process/night_lighting/proc/deactivate(var/whitelisted_only = 1)
|
|
isactive = 0
|
|
for (var/obj/machinery/power/apc/APC in get_apc_list(whitelisted_only))
|
|
APC.toggle_nightlight("off")
|
|
|
|
F_SCHECK
|
|
|
|
/datum/controller/process/night_lighting/proc/get_apc_list(var/whitelisted_only = 1)
|
|
var/list/obj/machinery/power/apc/lighting_apcs = list()
|
|
|
|
for (var/A in all_areas)
|
|
var/area/B = A
|
|
if (B.no_light_control || (!(B.allow_nightmode) && whitelisted_only))
|
|
continue
|
|
if (B.apc && !B.apc.aidisabled)
|
|
lighting_apcs += B.apc
|
|
|
|
F_SCHECK
|
|
|
|
return lighting_apcs
|