#define MACHINERY_GO_TO_NEXT if (no_mc_tick) { CHECK_TICK; } else if (MC_TICK_CHECK) { return; } else { continue; }
|
|
|
|
/var/datum/controller/subsystem/machinery/SSmachinery
|
|
|
|
/datum/controller/subsystem/machinery
|
|
name = "Machinery"
|
|
priority = SS_PRIORITY_MACHINERY
|
|
init_order = SS_INIT_MACHINERY
|
|
flags = SS_POST_FIRE_TIMING
|
|
|
|
var/tmp/list/all_machines = list() // A list of all machines. Including the non-processing ones.
|
|
var/tmp/list/processing_machines = list() // A list of machines that process.
|
|
|
|
var/tmp/list/working_machinery = list() // A list of machinery left to process this work cycle.
|
|
var/tmp/list/working_powersinks = list() // A list of machinery draining power to process this work cycle.
|
|
var/tmp/powernets_reset_yet
|
|
|
|
var/tmp/processes_this_tick = 0
|
|
var/tmp/powerusers_this_tick = 0
|
|
|
|
var/list/all_cameras = list()
|
|
var/list/all_status_displays = list() // Note: This contains both ai_status_display and status_display.
|
|
var/list/gravity_generators = list()
|
|
|
|
var/rcon_update_queued = FALSE
|
|
var/powernet_update_queued = FALSE
|
|
|
|
var/list/slept_in_process = list()
|
|
|
|
// Cooking stuff. Not substantial enough to get its own SS, so it's shoved in here.
|
|
var/list/recipe_datums = list()
|
|
|
|
/datum/controller/subsystem/machinery/Recover()
|
|
all_cameras = SSmachinery.all_cameras
|
|
recipe_datums = SSmachinery.recipe_datums
|
|
|
|
/datum/controller/subsystem/machinery/proc/queue_rcon_update()
|
|
rcon_update_queued = TRUE
|
|
|
|
/datum/controller/subsystem/machinery/New()
|
|
NEW_SS_GLOBAL(SSmachinery)
|
|
|
|
#define ADD_TO_RDATUMS(i,t) if (R.appliance & i) { LAZYADD(recipe_datums["[i]"], t); added++; }
|
|
|
|
/datum/controller/subsystem/machinery/Initialize(timeofday)
|
|
for (var/type in subtypesof(/datum/recipe))
|
|
var/datum/recipe/R = new type
|
|
var/added = 0
|
|
ADD_TO_RDATUMS(MICROWAVE, R)
|
|
ADD_TO_RDATUMS(FRYER, R)
|
|
ADD_TO_RDATUMS(OVEN, R)
|
|
ADD_TO_RDATUMS(CANDYMAKER, R)
|
|
ADD_TO_RDATUMS(CEREALMAKER, R)
|
|
if (!added)
|
|
log_debug("SSmachinery: warning: type '[type]' does not have a valid machine type.")
|
|
qdel(R)
|
|
|
|
fire(FALSE, TRUE) // Tick machinery once to pare down the list so we don't hammer the server on round-start.
|
|
..(timeofday)
|
|
|
|
#undef ADD_TO_RDATUMS
|
|
|
|
/datum/controller/subsystem/machinery/fire(resumed = 0, no_mc_tick = FALSE)
|
|
if (!resumed)
|
|
src.working_machinery = processing_machines.Copy()
|
|
src.working_powersinks = processing_power_items.Copy()
|
|
powernets_reset_yet = FALSE
|
|
|
|
// Reset accounting vars.
|
|
processes_this_tick = 0
|
|
powerusers_this_tick = 0
|
|
|
|
if (rcon_update_queued)
|
|
rcon_update_queued = FALSE
|
|
SSpower.build_rcon_lists()
|
|
|
|
if (powernet_update_queued)
|
|
makepowernets()
|
|
powernet_update_queued = FALSE
|
|
|
|
var/list/curr_machinery = working_machinery
|
|
var/list/curr_powersinks = working_powersinks
|
|
|
|
while (curr_machinery.len)
|
|
var/obj/machinery/M = curr_machinery[curr_machinery.len]
|
|
curr_machinery.len--
|
|
|
|
if (QDELETED(M))
|
|
log_debug("SSmachinery: QDELETED machine [DEBUG_REF(M)] found in machines list! Removing.")
|
|
remove_machine(M, TRUE)
|
|
continue
|
|
|
|
var/start_tick = world.time
|
|
|
|
if (M.machinery_processing)
|
|
processes_this_tick++
|
|
switch (M.machinery_process())
|
|
if (PROCESS_KILL)
|
|
remove_machine(M, FALSE)
|
|
if (M_NO_PROCESS)
|
|
M.machinery_processing = FALSE
|
|
|
|
if (start_tick != world.time)
|
|
// Slept.
|
|
if (!slept_in_process[M.type])
|
|
log_debug("SSmachinery: Type '[M.type]' slept during machinery_process().")
|
|
slept_in_process[M.type] = TRUE
|
|
|
|
// I'm sorry.
|
|
if (M.use_power && isturf(M.loc))
|
|
powerusers_this_tick++
|
|
if (M.has_special_power_checks)
|
|
M.auto_use_power()
|
|
else
|
|
var/area/A = M.loc.loc
|
|
var/chan = M.power_channel
|
|
if ((A.has_weird_power && !A.powered(chan)))
|
|
MACHINERY_GO_TO_NEXT
|
|
if (A.requires_power)
|
|
if (A.always_unpowered)
|
|
MACHINERY_GO_TO_NEXT
|
|
switch (chan)
|
|
if (EQUIP)
|
|
if (!A.power_equip)
|
|
MACHINERY_GO_TO_NEXT
|
|
if (LIGHT)
|
|
if (!A.power_light)
|
|
MACHINERY_GO_TO_NEXT
|
|
if (ENVIRON)
|
|
if (!A.power_environ)
|
|
MACHINERY_GO_TO_NEXT
|
|
else // ?!
|
|
log_debug("SSmachinery: Type '[M.type]' has insane channel [chan] (expected value in range 1-3).")
|
|
M.use_power = FALSE
|
|
MACHINERY_GO_TO_NEXT
|
|
|
|
if (A.has_weird_power)
|
|
A.use_power(M.use_power == 2 ? M.active_power_usage : M.idle_power_usage, chan)
|
|
else
|
|
switch (chan)
|
|
if (EQUIP)
|
|
A.used_equip += M.use_power == 2 ? M.active_power_usage : M.idle_power_usage
|
|
if (LIGHT)
|
|
A.used_light += M.use_power == 2 ? M.active_power_usage : M.idle_power_usage
|
|
if (ENVIRON)
|
|
A.used_environ += M.use_power == 2 ? M.active_power_usage : M.idle_power_usage
|
|
else // ?!
|
|
log_debug("SSmachinery: Type '[M.type]' has insane channel [chan] (expected value in range 1-3).")
|
|
M.use_power = FALSE
|
|
|
|
if (no_mc_tick)
|
|
CHECK_TICK
|
|
else if (MC_TICK_CHECK)
|
|
return
|
|
|
|
if (!powernets_reset_yet)
|
|
SSpower.reset_powernets()
|
|
powernets_reset_yet = TRUE
|
|
|
|
while (curr_powersinks.len)
|
|
var/obj/item/I = curr_powersinks[curr_powersinks.len]
|
|
curr_powersinks.len--
|
|
|
|
if (QDELETED(I) || !I.pwr_drain())
|
|
processing_power_items -= I
|
|
log_debug("SSmachinery: QDELETED item [DEBUG_REF(I)] found in processing power items list.")
|
|
|
|
if (no_mc_tick)
|
|
CHECK_TICK
|
|
else if (MC_TICK_CHECK)
|
|
return
|
|
|
|
/datum/controller/subsystem/machinery/stat_entry()
|
|
var/list/out = list()
|
|
out += "AM:[all_machines.len] PM:[processing_machines.len] PI:[processing_power_items.len]"
|
|
out += "LT:{T:[processes_this_tick]|P:[powerusers_this_tick]}"
|
|
..(out.Join("\n\t"))
|
|
|
|
/datum/controller/subsystem/machinery/proc/setup_template_powernets(list/cables)
|
|
for(var/A in cables)
|
|
var/obj/structure/cable/PC = A
|
|
if(!PC.powernet)
|
|
var/datum/powernet/NewPN = new()
|
|
NewPN.add_cable(PC)
|
|
propagate_network(PC, PC.powernet)
|
|
|
|
/**
|
|
* @brief Adds a machine to the SSmachinery.processing_machines and the SSmachinery.all_machines list.
|
|
*
|
|
* Must be called in every machine's Initialize(). Is called in the parent override of that proc
|
|
* by default.
|
|
*
|
|
* @param M The machine we want to add.
|
|
*/
|
|
/proc/add_machine(obj/machinery/M)
|
|
if (QDELETED(M))
|
|
crash_with("Attempted add of QDELETED machine [M ? M : "NULL"] to machines list, ignoring.")
|
|
return
|
|
|
|
M.machinery_processing = TRUE
|
|
if (SSmachinery.processing_machines[M])
|
|
crash_with("Type [M.type] was added to the processing machines list twice! Ignoring duplicate.")
|
|
|
|
SSmachinery.processing_machines[M] = TRUE
|
|
SSmachinery.all_machines[M] = TRUE
|
|
|
|
/**
|
|
* @brief Removes a machine from all of the default global lists it's in.
|
|
*
|
|
* @param M The machine we want to remove.
|
|
* @param remove_from_global Boolean to indicate wether or not the machine should
|
|
* also be removed from the all_machines list. Defaults to FALSE.
|
|
*/
|
|
/proc/remove_machine(obj/machinery/M, remove_from_global = FALSE)
|
|
if (M)
|
|
M.machinery_processing = FALSE
|
|
|
|
SSmachinery.processing_machines -= M
|
|
SSmachinery.working_machinery -= M
|
|
|
|
if (remove_from_global)
|
|
SSmachinery.all_machines -= M
|
|
|
|
|
|
/datum/controller/subsystem/machinery/ExplosionStart()
|
|
suspend()
|
|
|
|
/datum/controller/subsystem/machinery/ExplosionEnd()
|
|
wake()
|
|
|
|
#undef MACHINERY_GO_TO_NEXT
|