// Powersink - used to drain station power
|
|
|
|
/obj/item/device/powersink
|
|
name = "power sink"
|
|
desc = "A nulling power sink which drains energy from electrical systems."
|
|
icon_state = "powersink0"
|
|
item_state = "powersink0"
|
|
w_class = ITEMSIZE_LARGE
|
|
flags = CONDUCT
|
|
throwforce = 5
|
|
throw_speed = 1
|
|
throw_range = 2
|
|
|
|
matter = list(DEFAULT_WALL_MATERIAL = 750)
|
|
|
|
origin_tech = list(TECH_POWER = 3, TECH_ILLEGAL = 5)
|
|
var/drain_rate = 1500000 // amount of power to drain per tick
|
|
var/apc_drain_rate = 5000 // Max. amount drained from single APC. In Watts.
|
|
var/dissipation_rate = 20000 // Passive dissipation of drained power. In Watts.
|
|
var/power_drained = 0 // Amount of power drained.
|
|
var/max_power = 8e8 // Detonation point. Roughly 18 minutes with default setup.
|
|
var/mode = 0 // 0 = off, 1=clamped (off), 2=operating
|
|
var/drained_this_tick = 0 // This is unfortunately necessary to ensure we process powersinks BEFORE other machinery such as APCs.
|
|
|
|
var/datum/powernet/PN // Our powernet
|
|
var/obj/structure/cable/attached // the attached cable
|
|
|
|
/obj/item/device/powersink/Destroy()
|
|
STOP_PROCESSING_POWER_OBJECT(src)
|
|
processing_power_items -= src
|
|
|
|
return ..()
|
|
|
|
/obj/item/device/powersink/attackby(var/obj/item/I, var/mob/user)
|
|
if(I.isscrewdriver())
|
|
if(mode == 0)
|
|
var/turf/T = loc
|
|
if(isturf(T) && !!T.is_plating())
|
|
attached = locate() in T
|
|
if(!attached)
|
|
to_chat(user, "<span class='warning'>No exposed cable here to attach to.</span>")
|
|
else
|
|
anchored = 1
|
|
mode = 1
|
|
visible_message("<span class='notice'>\The [user] attaches \the [src] to the cable!</span>")
|
|
else
|
|
to_chat(user, "<span class='warning'>\The [src] must be placed over an exposed cable to attach to it.</span>")
|
|
return TRUE
|
|
else
|
|
if (mode == 2)
|
|
STOP_PROCESSING_POWER_OBJECT(src)
|
|
processing_power_items.Remove(src)
|
|
anchored = 0
|
|
mode = 0
|
|
visible_message("<span class='notice'>\The [user] detaches \the [src] from the cable!</span>")
|
|
set_light(0)
|
|
icon_state = "powersink0"
|
|
item_state = "powersink0"
|
|
|
|
return TRUE
|
|
else
|
|
return ..()
|
|
|
|
/obj/item/device/powersink/attack_ai()
|
|
return
|
|
|
|
/obj/item/device/powersink/attack_hand(var/mob/user)
|
|
switch(mode)
|
|
if(0)
|
|
..()
|
|
if(1)
|
|
visible_message("<span class='notice'>\The [user] activates \the [src]!</span>")
|
|
mode = 2
|
|
icon_state = "powersink1"
|
|
item_state = "powersink1"
|
|
START_PROCESSING_POWER_OBJECT(src)
|
|
processing_power_items += src
|
|
if(2) //This switch option wasn't originally included. It exists now. --NeoFite
|
|
visible_message("<span class='notice'>\The [user] deactivates \the [src]!</span>")
|
|
mode = 1
|
|
set_light(0)
|
|
icon_state = "powersink0"
|
|
item_state = "powersink0"
|
|
STOP_PROCESSING_POWER_OBJECT(src)
|
|
processing_power_items -= src
|
|
|
|
/obj/item/device/powersink/pwr_drain()
|
|
if(!attached)
|
|
return 0
|
|
|
|
if(drained_this_tick)
|
|
return 1
|
|
drained_this_tick = 1
|
|
|
|
var/drained = 0
|
|
|
|
if(!PN)
|
|
return 1
|
|
|
|
set_light(12)
|
|
PN.trigger_warning()
|
|
// found a powernet, so drain up to max power from it
|
|
drained = PN.draw_power(drain_rate)
|
|
// if tried to drain more than available on powernet
|
|
// now look for APCs and drain their cells
|
|
if(drained < drain_rate)
|
|
for(var/obj/machinery/power/terminal/T in PN.nodes)
|
|
// Enough power drained this tick, no need to torture more APCs
|
|
if(drained >= drain_rate)
|
|
break
|
|
if(istype(T.master, /obj/machinery/power/apc))
|
|
var/obj/machinery/power/apc/A = T.master
|
|
if(A.operating && A.cell)
|
|
var/cur_charge = A.cell.charge / CELLRATE
|
|
var/drain_val = min(apc_drain_rate, cur_charge)
|
|
A.cell.use(drain_val * CELLRATE)
|
|
drained += drain_val
|
|
power_drained += drained
|
|
return 1
|
|
|
|
|
|
/obj/item/device/powersink/process()
|
|
drained_this_tick = 0
|
|
power_drained -= min(dissipation_rate, power_drained)
|
|
|
|
if(attached && attached.powernet)
|
|
PN = attached.powernet
|
|
else
|
|
PN = null
|
|
|
|
if(power_drained > max_power * 0.98) // Lower the screeching period. It was pretty long during testing.
|
|
playsound(src, 'sound/effects/screech.ogg', 100, 1, 1)
|
|
|
|
if(power_drained >= max_power)
|
|
handle_overload()
|
|
qdel(src)
|
|
return
|
|
|
|
/obj/item/device/powersink/proc/handle_overload()
|
|
if (QDELETED(src))
|
|
return
|
|
|
|
// No attached node, or no powernet.
|
|
if (!PN)
|
|
explosion(src.loc, 0, 1, 3, 6)
|
|
return
|
|
|
|
// Propagate the power surge through the powernet nodes.
|
|
for (var/A in PN.nodes)
|
|
if (!A || A == src)
|
|
continue
|
|
|
|
var/dist = get_dist(src, A)
|
|
|
|
if (dist < 1)
|
|
dist = 1 // For later calculations.
|
|
else if (dist > 24)
|
|
continue // Out of range.
|
|
|
|
// Map it to a range of [3, 1] for severity.
|
|
dist = round(MAP(dist, 1, 28, 3, 1))
|
|
|
|
// Check for terminals and affect their master nodes. Also add a special
|
|
// case for APCs whereby their lights are popped or flicked.
|
|
if (istype(A, /obj/machinery/power/terminal))
|
|
var/obj/machinery/power/terminal/T = A
|
|
if (istype(T.master, /obj/machinery/power/apc))
|
|
var/obj/machinery/power/apc/AP = T.master
|
|
if (dist > 1)
|
|
AP.overload_lighting(100, TRUE)
|
|
else
|
|
AP.flicker_all()
|
|
else if (T.master)
|
|
T.master.emp_act(dist)
|
|
|
|
var/atom/aa = A
|
|
aa.emp_act(dist)
|
|
|
|
if (prob(15 * dist))
|
|
explosion(aa.loc, 0, 0, 3, 4)
|
|
|
|
// Also destroy the source.
|
|