var/datum/controller/process/night_lighting/nl_ctrl
/datum/controller/process/night_lighting/
var/isactive = 0
var/firstrun = 1
var/manual_override = 0
/datum/controller/process/night_lighting/proc/is_active()
return isactive
/datum/controller/process/night_lighting/setup()
name = "night lighting controller"
schedule_interval = 3600 // Every 5 minutes.
nl_ctrl = src
if (!config.night_lighting)
// Stop trying to delete processes. Not how it goes.
disabled = 1
/datum/controller/process/night_lighting/preStart()
switch (worldtime2ticks())
if (0 to config.nl_finish)
deactivate()
if (config.nl_start to TICKS_IN_DAY)
activate()
/datum/controller/process/night_lighting/doWork()
if (manual_override) // don't automatically change lighting if it was manually changed in-game
return
switch (worldtime2ticks())
if (0 to config.nl_finish)
if (isactive)
command_announcement.Announce("Good morning. The time is [worldtime2text()]. \n\nThe automated systems aboard the [station_name()] will now return the public hallway lighting levels to normal.", "Automated Lighting System", new_sound = 'sound/misc/bosuns_whistle.ogg')
deactivate()
if (config.nl_start to TICKS_IN_DAY)
if (!isactive)
command_announcement.Announce("Good evening. The time is [worldtime2text()]. \n\nThe automated systems aboard the [station_name()] will now dim lighting in the public hallways in order to accommodate the circadian rhythm of some species.", "Automated Lighting System", new_sound = 'sound/misc/bosuns_whistle.ogg')
activate()
else
if (isactive)
deactivate()
// 'whitelisted' areas are areas that have nightmode explicitly enabled
/datum/controller/process/night_lighting/proc/activate(var/whitelisted_only = 1)
isactive = 1
for (var/obj/machinery/power/apc/APC in get_apc_list(whitelisted_only))
APC.toggle_nightlight("on")
SCHECK
/datum/controller/process/night_lighting/proc/deactivate(var/whitelisted_only = 1)
isactive = 0
for (var/obj/machinery/power/apc/APC in get_apc_list(whitelisted_only))
APC.toggle_nightlight("off")
SCHECK
/datum/controller/process/night_lighting/proc/get_apc_list(var/whitelisted_only = 1)
var/list/obj/machinery/power/apc/lighting_apcs = list()
for (var/A in all_areas)
var/area/B = A
if (B.no_light_control || (!(B.allow_nightmode) && whitelisted_only))
continue
if (B.apc && !B.apc.aidisabled)
lighting_apcs += B.apc
SCHECK
return lighting_apcs