Improves speed of redraw_lighting()

No longer uses animate() when unneeded, because animate() is slow.
Also turns Clamp() into a macro to reduce proccall overhead.

The whitespace changes in atmos are needed because of the way the
preprocessor handles macros.

Thank you MrPerson for helping with this.
This commit is contained in:
Tkdrg
2015-11-06 23:36:03 -03:00
parent 4892c79a0d
commit 3308f76efb
7 changed files with 15 additions and 56 deletions
@@ -176,25 +176,13 @@ Acts like a normal vent, but has an input AND output.
pump_direction = 1
if("set_input_pressure" in signal.data)
input_pressure_min = Clamp(
text2num(signal.data["set_input_pressure"]),
0,
ONE_ATMOSPHERE*50
)
input_pressure_min = Clamp(text2num(signal.data["set_input_pressure"]),0,ONE_ATMOSPHERE*50)
if("set_output_pressure" in signal.data)
output_pressure_max = Clamp(
text2num(signal.data["set_output_pressure"]),
0,
ONE_ATMOSPHERE*50
)
output_pressure_max = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if("set_external_pressure" in signal.data)
external_pressure_bound = Clamp(
text2num(signal.data["set_external_pressure"]),
0,
ONE_ATMOSPHERE*50
)
external_pressure_bound = Clamp(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
if("status" in signal.data)
spawn(2)
@@ -124,11 +124,7 @@ Passive gate is similar to the regular pump except:
on = !on
if("set_output_pressure" in signal.data)
target_pressure = Clamp(
text2num(signal.data["set_output_pressure"]),
0,
ONE_ATMOSPHERE*50
)
target_pressure = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
@@ -129,11 +129,7 @@ Thus, the two variables affect pump operation are set in New():
on = !on
if("set_output_pressure" in signal.data)
target_pressure = Clamp(
text2num(signal.data["set_output_pressure"]),
0,
ONE_ATMOSPHERE*50
)
target_pressure = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
@@ -126,11 +126,7 @@ Thus, the two variables affect pump operation are set in New():
if("set_transfer_rate" in signal.data)
var/datum/gas_mixture/air1 = AIR1
transfer_rate = Clamp(
text2num(signal.data["set_transfer_rate"]),
0,
air1.volume
)
transfer_rate = Clamp(text2num(signal.data["set_transfer_rate"]),0,air1.volume)
if(on != old_on)