Merge pull request #9466 from Fayrik/TheNanoing

The Nanoing (Episode 2: The Fix Wars)
This commit is contained in:
phil235
2015-06-22 14:24:20 +02:00
19 changed files with 139 additions and 189 deletions
@@ -92,24 +92,18 @@ Passive gate is similar to the regular pump except:
return 1
/obj/machinery/atmospherics/binary/passive_gate/ui_interact(mob/user, ui_key = "main")
/obj/machinery/atmospherics/binary/passive_gate/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null)
if(stat & (BROKEN|NOPOWER))
return
var/data = list()
ui = SSnano.push_open_or_new_ui(user, src, ui_key, ui, "atmos_gas_pump.tmpl", name, 400, 120, 0)
/obj/machinery/atmospherics/binary/passive_gate/get_ui_data()
var/data = list()
data["on"] = on
data["pressure_set"] = round(target_pressure*100) //Nano UI can't handle rounded non-integers, apparently.
data["max_pressure"] = MAX_OUTPUT_PRESSURE
var/datum/nanoui/ui = SSnano.get_open_ui(user, src, ui_key)
if (!ui)
ui = new /datum/nanoui(user, src, ui_key, "atmos_gas_pump.tmpl", name, 400, 120)
ui.set_initial_data(data)
ui.open()
ui.set_auto_update(1)
else
ui.push_data(data)
return data
/obj/machinery/atmospherics/binary/passive_gate/atmosinit()
..()
@@ -97,24 +97,18 @@ Thus, the two variables affect pump operation are set in New():
return 1
/obj/machinery/atmospherics/binary/pump/ui_interact(mob/user, ui_key = "main")
/obj/machinery/atmospherics/binary/pump/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null)
if(stat & (BROKEN|NOPOWER))
return
var/data = list()
ui = SSnano.push_open_or_new_ui(user, src, ui_key, ui, "atmos_gas_pump.tmpl", name, 400, 120, 0)
/obj/machinery/atmospherics/binary/pump/get_ui_data()
var/data = list()
data["on"] = on
data["pressure_set"] = round(target_pressure*100) //Nano UI can't handle rounded non-integers, apparently.
data["max_pressure"] = MAX_OUTPUT_PRESSURE
var/datum/nanoui/ui = SSnano.get_open_ui(user, src, ui_key)
if (!ui)
ui = new /datum/nanoui(user, src, ui_key, "atmos_gas_pump.tmpl", name, 400, 120)
ui.set_initial_data(data)
ui.open()
ui.set_auto_update(1)
else
ui.push_data(data)
return data
/obj/machinery/atmospherics/binary/pump/atmosinit()
..()
@@ -93,24 +93,18 @@ Thus, the two variables affect pump operation are set in New():
return 1
/obj/machinery/atmospherics/binary/volume_pump/ui_interact(mob/user, ui_key = "main")
/obj/machinery/atmospherics/binary/volume_pump/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null)
if(stat & (BROKEN|NOPOWER))
return
var/data = list()
ui = SSnano.push_open_or_new_ui(user, src, ui_key, ui, "atmos_gas_pump.tmpl", name, 400, 120, 0)
/obj/machinery/atmospherics/binary/volume_pump/get_ui_data()
var/data = list()
data["on"] = on
data["transfer_rate"] = round(transfer_rate*100) //Nano UI can't handle rounded non-integers, apparently.
data["max_rate"] = MAX_TRANSFER_RATE
var/datum/nanoui/ui = SSnano.get_open_ui(user, src, ui_key)
if (!ui)
ui = new /datum/nanoui(user, src, ui_key, "atmos_gas_pump.tmpl", name, 400, 120)
ui.set_initial_data(data)
ui.open()
ui.set_auto_update(1)
else
ui.push_data(data)
return data
/obj/machinery/atmospherics/binary/volume_pump/atmosinit()
..()