Speeds up area power usage handling, and apc process(). Cleans up related code (#51002)

About The Pull Request

/area/proc/usage() attempts to give list-like access to a bunch of vars. Why not make it a list instead and avoid all the proc calls? Might be room for followup here, to do something to powered(), use_power() etc.

Some legacy machinery was ignoring the default machinery use_power pulling from the machine's power channel by default

Total power usage was unused, APCs ignored it in favor of calculating it themselves :)

I also renamed the defines because they were in the danger zone of being very common words.
Changelog

cl Naksu
code: optimized area power usage calculations.
/cl
This commit is contained in:
vuonojenmustaturska
2020-05-11 02:33:56 +03:00
committed by GitHub
parent b9920f6caf
commit 5e1f57de77
34 changed files with 184 additions and 210 deletions
@@ -1,91 +1,91 @@
/obj/item/computer_hardware/recharger
critical = 1
enabled = 1
var/charge_rate = 100
device_type = MC_CHARGE
/obj/item/computer_hardware/recharger/proc/use_power(amount, charging=0)
if(charging)
return 1
return 0
/obj/item/computer_hardware/recharger/process()
..()
var/obj/item/computer_hardware/battery/battery_module = holder.all_components[MC_CELL]
if(!holder || !battery_module || !battery_module.battery)
return
var/obj/item/stock_parts/cell/cell = battery_module.battery
if(cell.charge >= cell.maxcharge)
return
if(use_power(charge_rate, charging=1))
holder.give_power(charge_rate * GLOB.CELLRATE)
/obj/item/computer_hardware/recharger/APC
name = "area power connector"
desc = "A device that wirelessly recharges connected device from nearby APC."
icon_state = "charger_APC"
w_class = WEIGHT_CLASS_SMALL // Can't be installed into tablets/PDAs
/obj/item/computer_hardware/recharger/APC/use_power(amount, charging=0)
if(ismachinery(holder.physical))
var/obj/machinery/M = holder.physical
if(M.powered())
M.use_power(amount)
return 1
else
var/area/A = get_area(src)
if(!istype(A))
return 0
if(A.powered(EQUIP))
A.use_power(amount, EQUIP)
return 1
return 0
/obj/item/computer_hardware/recharger/wired
name = "wired power connector"
desc = "A power connector that recharges connected device from nearby power wire. Incompatible with portable computers."
icon_state = "charger_wire"
w_class = WEIGHT_CLASS_NORMAL
/obj/item/computer_hardware/recharger/wired/can_install(obj/item/modular_computer/M, mob/living/user = null)
if(ismachinery(M.physical) && M.physical.anchored)
return ..()
to_chat(user, "<span class='warning'>\The [src] is incompatible with portable computers!</span>")
return 0
/obj/item/computer_hardware/recharger/wired/use_power(amount, charging=0)
if(ismachinery(holder.physical) && holder.physical.anchored)
var/obj/machinery/M = holder.physical
var/turf/T = M.loc
if(!T || !istype(T))
return 0
var/obj/structure/cable/C = T.get_cable_node()
if(!C || !C.powernet)
return 0
var/power_in_net = C.powernet.avail-C.powernet.load
if(power_in_net && power_in_net > amount)
C.powernet.load += amount
return 1
return 0
// This is not intended to be obtainable in-game. Intended for adminbus and debugging purposes.
/obj/item/computer_hardware/recharger/lambda
name = "lambda coil"
desc = "A very complex device that draws power from its own bluespace dimension."
icon_state = "charger_lambda"
w_class = WEIGHT_CLASS_TINY
charge_rate = 100000
/obj/item/computer_hardware/recharger/lambda/use_power(amount, charging=0)
return 1
/obj/item/computer_hardware/recharger
critical = 1
enabled = 1
var/charge_rate = 100
device_type = MC_CHARGE
/obj/item/computer_hardware/recharger/proc/use_power(amount, charging=0)
if(charging)
return 1
return 0
/obj/item/computer_hardware/recharger/process()
..()
var/obj/item/computer_hardware/battery/battery_module = holder.all_components[MC_CELL]
if(!holder || !battery_module || !battery_module.battery)
return
var/obj/item/stock_parts/cell/cell = battery_module.battery
if(cell.charge >= cell.maxcharge)
return
if(use_power(charge_rate, charging=1))
holder.give_power(charge_rate * GLOB.CELLRATE)
/obj/item/computer_hardware/recharger/APC
name = "area power connector"
desc = "A device that wirelessly recharges connected device from nearby APC."
icon_state = "charger_APC"
w_class = WEIGHT_CLASS_SMALL // Can't be installed into tablets/PDAs
/obj/item/computer_hardware/recharger/APC/use_power(amount, charging=0)
if(ismachinery(holder.physical))
var/obj/machinery/M = holder.physical
if(M.powered())
M.use_power(amount)
return 1
else
var/area/A = get_area(src)
if(!istype(A))
return 0
if(A.powered(AREA_USAGE_EQUIP))
A.use_power(amount, AREA_USAGE_EQUIP)
return 1
return 0
/obj/item/computer_hardware/recharger/wired
name = "wired power connector"
desc = "A power connector that recharges connected device from nearby power wire. Incompatible with portable computers."
icon_state = "charger_wire"
w_class = WEIGHT_CLASS_NORMAL
/obj/item/computer_hardware/recharger/wired/can_install(obj/item/modular_computer/M, mob/living/user = null)
if(ismachinery(M.physical) && M.physical.anchored)
return ..()
to_chat(user, "<span class='warning'>\The [src] is incompatible with portable computers!</span>")
return 0
/obj/item/computer_hardware/recharger/wired/use_power(amount, charging=0)
if(ismachinery(holder.physical) && holder.physical.anchored)
var/obj/machinery/M = holder.physical
var/turf/T = M.loc
if(!T || !istype(T))
return 0
var/obj/structure/cable/C = T.get_cable_node()
if(!C || !C.powernet)
return 0
var/power_in_net = C.powernet.avail-C.powernet.load
if(power_in_net && power_in_net > amount)
C.powernet.load += amount
return 1
return 0
// This is not intended to be obtainable in-game. Intended for adminbus and debugging purposes.
/obj/item/computer_hardware/recharger/lambda
name = "lambda coil"
desc = "A very complex device that draws power from its own bluespace dimension."
icon_state = "charger_lambda"
w_class = WEIGHT_CLASS_TINY
charge_rate = 100000
/obj/item/computer_hardware/recharger/lambda/use_power(amount, charging=0)
return 1