mirror of
https://github.com/Bubberstation/Bubberstation.git
synced 2026-08-22 20:48:56 +01:00
[MIRROR] Pump pressure calculation now respects temperature. [MDB IGNORE] (#10812)
* Pump pressure calculation now respects temperature. (#62320) Ever pump hot nob into a tank of oxygen, see the pressure rise to 8000 kpa for a few seconds and have that deafening explosion sound play right after? This attempts to eliminate those by making the pressure transfer proc thingy in gas_mixture account for resulting temperature. The old one is preserved if the temperature difference isn't too big because it's most definitely more performant. The minimum temperature difference of 5 is completely arbitrary and I won't mind changing if asked. Math is a bit messy by necessity but I hope the comment is adequate. While I'm at it i also changed the return value of those procs to return a removed gasmix instead of directly merging. I sort of needed this for a clean implementation of assume_air in #62284. Will need more testing though. Found a better solution. Writes a small unit test to check for this too. Cuts down on one unintended cause of explosions. * Pump pressure calculation now respects temperature. Co-authored-by: vincentiusvin <54709710+vincentiusvin@users.noreply.github.com>
This commit is contained in:
co-authored by
vincentiusvin
parent
cc6dbb3344
commit
640559580e
@@ -67,6 +67,7 @@
|
||||
#include "egg_glands.dm"
|
||||
#include "emoting.dm"
|
||||
#include "food_edibility_check.dm"
|
||||
#include "gas_transfer.dm"
|
||||
#include "greyscale_config.dm"
|
||||
#include "heretic_knowledge.dm"
|
||||
#include "holidays.dm"
|
||||
|
||||
@@ -0,0 +1,32 @@
|
||||
/// Test to make sure the pressure pumping proc used by things like portable pumps, pressure pumps, etc actually work.
|
||||
/datum/unit_test/atmospheric_gas_transfer
|
||||
|
||||
/datum/unit_test/atmospheric_gas_transfer/Run()
|
||||
for (var/tempNmoles in list(1e4, 1e6, 1e8, 1e10, 1e12))
|
||||
var/datum/gas_mixture/first_mix = allocate(/datum/gas_mixture)
|
||||
var/datum/gas_mixture/second_mix = allocate(/datum/gas_mixture)
|
||||
|
||||
first_mix.volume = 200
|
||||
second_mix.volume = 200
|
||||
|
||||
ASSERT_GAS(/datum/gas/hypernoblium, first_mix)
|
||||
ASSERT_GAS(/datum/gas/tritium, second_mix)
|
||||
first_mix.gases[/datum/gas/hypernoblium][MOLES] = tempNmoles
|
||||
second_mix.gases[/datum/gas/tritium][MOLES] = 200
|
||||
first_mix.temperature = tempNmoles
|
||||
second_mix.temperature = T20C
|
||||
|
||||
var/initial_pressure = second_mix.return_pressure()
|
||||
// A constant value would be nicer but there will be cases when even MOLAR_ACCURACY amounts would far exceed the pressure so we need to scale it somewhat.
|
||||
var/additional_pressure = (tempNmoles / 1000) + 500
|
||||
|
||||
/* ERROR MARGIN CALCULATION
|
||||
* We calculate how much would the pressure change if MOLAR_ACCURACY amount of hothotgas is imparted on the cold mix.
|
||||
* This number gets really big for very high temperatures so it's somewhat meaningless, but our main goal is to ensure the code doesn't break.
|
||||
*/
|
||||
var/error_margin = first_mix.gas_pressure_minimum_transfer(second_mix) - initial_pressure
|
||||
|
||||
first_mix.pump_gas_to(second_mix, (initial_pressure + additional_pressure))
|
||||
var/margin = abs(second_mix.return_pressure() - (initial_pressure+additional_pressure))
|
||||
|
||||
TEST_ASSERT(margin<=error_margin, "Gas pressure pumping test failed for [tempNmoles]. Expected pressure = [initial_pressure+additional_pressure] +/- [error_margin]. Got [second_mix.return_pressure()].")
|
||||
Reference in New Issue