## About The Pull Request **1. Qol** - Air sensors(maploaded & hand crafted) now auto connect to any input ports & output valves that are within a 4 tile radius from it meaning there is no need for these ports to have unique IDs attached to them & you don't need a multitool to link them together if you first placed those ports & then placed the air sensor close to them - Atmos control monitors now finds all air sensors that are closest to it within the same z level meaning you can have/place multiple air sensors of the same type on the same z level & the monitor will locate them correctly without any ambiguity **2. Refactor** - Removed var `chamber_id` from both injectors & vents meaning you don't need to have unique ids assigned to them. As long as mappers/players put them within 4 tile radius from the air sensor it will auto connect to them - Removed var `GLOB.map_loaded_sensors` ## Changelog 🆑 qol: hand crafted air sensors now auto connect to input & output ports if they are located within a 4 tile radius from it qol: atmos control monitors now locate all air sensors nearest to in on that same z level meaning you can have multiple air sensors of the same type on the same map refactor: refactored how air sensors & atmos monitors connect to each other. Please report any atmos computers that have missing input valves/output ports on their connected air sensors or those that don't list any air sensors at all on github /🆑 --------- Co-authored-by: LemonInTheDark <58055496+LemonInTheDark@users.noreply.github.com>
244 lines
7.8 KiB
Plaintext
244 lines
7.8 KiB
Plaintext
/// GENERAL AIR CONTROL (a.k.a atmos computer)
|
|
/obj/machinery/computer/atmos_control
|
|
name = "atmospherics monitoring"
|
|
desc = "Used to monitor the station's atmospherics sensors."
|
|
icon_screen = "tank"
|
|
icon_keyboard = "atmos_key"
|
|
circuit = /obj/item/circuitboard/computer/atmos_control
|
|
light_color = LIGHT_COLOR_CYAN
|
|
|
|
/// Which sensors do we want to listen to.
|
|
/// Assoc of list[chamber_id] = readable_chamber_name
|
|
var/list/atmos_chambers = list()
|
|
/// list of all sensors[key is chamber id, value is id of air sensor linked to this chamber] monitered by this computer
|
|
var/list/connected_sensors = list()
|
|
/// Whether we can actually adjust the chambers or not.
|
|
var/control = TRUE
|
|
/// Whether we are allowed to reconnect.
|
|
var/reconnecting = TRUE
|
|
///OUur last reconnected chamber
|
|
VAR_PRIVATE/last_chamber_id = ""
|
|
|
|
/obj/machinery/computer/atmos_control/post_machine_initialize()
|
|
. = ..()
|
|
|
|
scan()
|
|
|
|
///Scans the z level for new air sensors & monitors
|
|
/obj/machinery/computer/atmos_control/proc/scan()
|
|
PRIVATE_PROC(TRUE)
|
|
|
|
//collect all sensors that are the closest to this computer
|
|
var/list/closest_sensors = list()
|
|
var/turf/comp_turf = get_turf(src)
|
|
for(var/obj/machinery/sensor as anything in (SSmachines.get_machines_by_type_and_subtypes(/obj/machinery/air_sensor) + SSmachines.get_machines_by_type_and_subtypes(/obj/machinery/meter/monitored)))
|
|
//same z level
|
|
if(sensor.z != z)
|
|
continue
|
|
//infer chamber id
|
|
var/chamber_id = ""
|
|
if(istype(sensor, /obj/machinery/air_sensor))
|
|
var/obj/machinery/air_sensor/air_sense = sensor
|
|
chamber_id = air_sense.chamber_id
|
|
else
|
|
var/obj/machinery/meter/monitored/meter = sensor
|
|
chamber_id = meter.chamber_id
|
|
//track & collect closest sensors
|
|
if(!closest_sensors[chamber_id])
|
|
closest_sensors[chamber_id] = sensor
|
|
continue
|
|
var/obj/machinery/target = closest_sensors[chamber_id]
|
|
if(get_dist(comp_turf, get_turf(sensor)) < get_dist(comp_turf, get_turf(target)))
|
|
closest_sensors[chamber_id] = sensor
|
|
//convert sensor list to id tags
|
|
connected_sensors.Cut()
|
|
for(var/chamber_id in closest_sensors)
|
|
var/obj/machinery/target = closest_sensors[chamber_id]
|
|
connected_sensors[chamber_id] = target.id_tag
|
|
|
|
/// Reconnect only works for station based chambers.
|
|
/obj/machinery/computer/atmos_control/proc/reconnect(mob/user)
|
|
if(!reconnecting)
|
|
return FALSE
|
|
|
|
scan()
|
|
|
|
// We only prompt the user with the sensors that are actually available.
|
|
var/available_devices = list()
|
|
for (var/chamber_identifier in connected_sensors)
|
|
//this sensor was destroyed at the time of reconnecting
|
|
var/obj/machinery/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber_identifier]]
|
|
if(QDELETED(sensor))
|
|
connected_sensors -= chamber_identifier
|
|
continue
|
|
|
|
//non master computers don't have access to these station moniters. Only done to give master computer's special access to these chambers and make them feel special or something
|
|
if(chamber_identifier == ATMOS_GAS_MONITOR_DISTRO)
|
|
continue
|
|
if(chamber_identifier == ATMOS_GAS_MONITOR_WASTE)
|
|
continue
|
|
|
|
available_devices[GLOB.station_gas_chambers[chamber_identifier]] = chamber_identifier
|
|
|
|
// As long as we dont put any funny chars in the strings it should match.
|
|
var/new_name = tgui_input_list(user, "Select the device set", "Reconnect", available_devices)
|
|
if(isnull(new_name))
|
|
return FALSE
|
|
var/new_id = available_devices[new_name]
|
|
if(isnull(new_id))
|
|
return FALSE
|
|
|
|
atmos_chambers -= last_chamber_id
|
|
atmos_chambers[new_id] = new_name
|
|
last_chamber_id = new_id
|
|
|
|
name = new_name + (control ? " Control" : " Monitor")
|
|
|
|
return TRUE
|
|
|
|
/obj/machinery/computer/atmos_control/ui_interact(mob/user, datum/tgui/ui)
|
|
. = ..()
|
|
ui = SStgui.try_update_ui(user, src, ui)
|
|
if(!ui)
|
|
ui = new(user, src, "AtmosControlConsole", name)
|
|
ui.open()
|
|
|
|
/obj/machinery/computer/atmos_control/ui_static_data(mob/user)
|
|
var/data = list()
|
|
data["maxInput"] = MAX_TRANSFER_RATE
|
|
data["maxOutput"] = MAX_OUTPUT_PRESSURE
|
|
data["control"] = control
|
|
data["reconnecting"] = reconnecting
|
|
data += return_atmos_handbooks()
|
|
return data
|
|
|
|
/obj/machinery/computer/atmos_control/ui_data(mob/user)
|
|
var/data = list()
|
|
|
|
data["chambers"] = list()
|
|
for(var/chamber_id in atmos_chambers)
|
|
var/list/chamber_info = list()
|
|
chamber_info["id"] = chamber_id
|
|
chamber_info["name"] = atmos_chambers[chamber_id]
|
|
|
|
var/obj/machinery/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber_id]]
|
|
if(!QDELETED(sensor))
|
|
chamber_info["gasmix"] = gas_mixture_parser(sensor.return_air())
|
|
|
|
if(istype(sensor, /obj/machinery/air_sensor)) //distro & waste loop are not air sensors and don't have these functions
|
|
var/obj/machinery/air_sensor/air_sensor = sensor
|
|
|
|
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[air_sensor.inlet_id || ""]
|
|
if (!QDELETED(input))
|
|
chamber_info["input_info"] = list(
|
|
"active" = input.on,
|
|
"amount" = input.volume_rate,
|
|
)
|
|
|
|
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[air_sensor.outlet_id || ""]
|
|
if (!QDELETED(output))
|
|
chamber_info["output_info"] = list(
|
|
"active" = output.on,
|
|
"amount" = output.internal_pressure_bound,
|
|
)
|
|
|
|
data["chambers"] += list(chamber_info)
|
|
return data
|
|
|
|
/obj/machinery/computer/atmos_control/ui_act(action, list/params, datum/tgui/ui, datum/ui_state/state)
|
|
. = ..()
|
|
if(. || !(control || reconnecting))
|
|
return
|
|
|
|
var/chamber = params["chamber"]
|
|
switch(action)
|
|
if("toggle_input")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[sensor.inlet_id || ""]
|
|
if(QDELETED(input))
|
|
return TRUE
|
|
|
|
input.on = !input.on
|
|
input.update_appearance(UPDATE_ICON)
|
|
return TRUE
|
|
|
|
if("toggle_output")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[sensor.outlet_id || ""]
|
|
if(QDELETED(output))
|
|
return TRUE
|
|
|
|
output.on = !output.on
|
|
output.update_appearance(UPDATE_ICON)
|
|
return TRUE
|
|
|
|
if("adjust_input")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/outlet_injector/input = GLOB.objects_by_id_tag[sensor.inlet_id || ""]
|
|
if(QDELETED(input))
|
|
return TRUE
|
|
|
|
var/target = text2num(params["rate"])
|
|
if(isnull(target))
|
|
return TRUE
|
|
target = clamp(target, 0, MAX_TRANSFER_RATE)
|
|
|
|
input.volume_rate = clamp(target, 0, min(input.airs[1].volume, MAX_TRANSFER_RATE))
|
|
return TRUE
|
|
|
|
if("adjust_output")
|
|
if (!(chamber in atmos_chambers))
|
|
return TRUE
|
|
|
|
var/obj/machinery/air_sensor/sensor = GLOB.objects_by_id_tag[connected_sensors[chamber]]
|
|
if(QDELETED(sensor))
|
|
return TRUE
|
|
|
|
var/obj/machinery/atmospherics/components/unary/vent_pump/output = GLOB.objects_by_id_tag[sensor.outlet_id || ""]
|
|
if(QDELETED(output))
|
|
return TRUE
|
|
|
|
var/target = text2num(params["rate"])
|
|
if(isnull(target))
|
|
return TRUE
|
|
target = clamp(target, 0, ATMOS_PUMP_MAX_PRESSURE)
|
|
|
|
output.internal_pressure_bound = target
|
|
return TRUE
|
|
|
|
if("reconnect")
|
|
reconnect(ui.user)
|
|
return TRUE
|
|
|
|
/obj/machinery/computer/atmos_control/nocontrol
|
|
control = FALSE
|
|
circuit = /obj/item/circuitboard/computer/atmos_control/nocontrol
|
|
|
|
/obj/machinery/computer/atmos_control/noreconnect
|
|
reconnecting = FALSE
|
|
circuit = /obj/item/circuitboard/computer/atmos_control/noreconnect
|
|
|
|
/// Vegetable
|
|
/obj/machinery/computer/atmos_control/fixed
|
|
control = FALSE
|
|
reconnecting = FALSE
|
|
circuit = /obj/item/circuitboard/computer/atmos_control/fixed
|