Bubberstation/code/modules/power/thermoelectric_generator.dm
Waterpig bb70889f6e TG Upstream Part 1
3591 individual conflicts

Update build.js

Update install_node.sh

Update byond.js

oh my fucking god

hat

slow

huh

holy shit

we all fall down

2 more I missed

2900 individual conflicts

2700 Individual conflicts

replaces yarn file with tg version, bumping us down to 2200-ish

Down to 2000 individual conflicts

140 down

mmm

aaaaaaaaaaaaaaaaaaa

not yt

575

soon

900 individual conflicts

600 individual conflicts, 121 file conflicts

im not okay

160 across 19 files

29 in 4 files

0 conflicts, compiletime fix time

some minor incap stuff

missed ticks

weird dupe definition stuff

missed ticks 2

incap fixes

undefs and pie fix

Radio update and some extra minor stuff

returns a single override

no more dupe definitions, 175 compiletime errors

Unticked file fix

sound and emote stuff

honk and more radio stuff
2024-10-19 08:04:33 -07:00

232 lines
8.1 KiB
Plaintext

/*
Skyrat removal START, moved to modular file
#define TEG_EFFICIENCY 0.65
/obj/machinery/power/thermoelectric_generator
name = "thermoelectric generator"
desc = "It's a high efficiency thermoelectric generator."
icon_state = "teg"
base_icon_state = "teg"
density = TRUE
use_power = NO_POWER_USE
circuit = /obj/item/circuitboard/machine/thermoelectric_generator
///The cold circulator machine, containing cold gas for the mix.
var/obj/machinery/atmospherics/components/binary/circulator/cold_circ
///The hot circulator machine, containing very hot gas for the mix.
var/obj/machinery/atmospherics/components/binary/circulator/hot_circ
///The amount of power the generator is currently producing.
var/lastgen = 0
///The amount of power the generator has last produced.
var/lastgenlev = -1
/**
* Used in overlays for the TEG, basically;
* one number is for the cold mix, one is for the hot mix
* If the cold mix has pressure in it, then the first number is 1, else 0
* If the hot mix has pressure in it, then the second number is 1, else 0
* Neither has pressure: 00
* Only cold has pressure: 10
* Only hot has pressure: 01
* Both has pressure: 11
*/
var/last_pressure_overlay = "00"
/obj/machinery/power/thermoelectric_generator/Initialize(mapload)
. = ..()
AddComponent(/datum/component/simple_rotation)
find_circulators()
connect_to_network()
SSair.start_processing_machine(src)
update_appearance()
/obj/machinery/power/thermoelectric_generator/Destroy()
null_circulators()
SSair.stop_processing_machine(src)
return ..()
/obj/machinery/power/thermoelectric_generator/on_deconstruction(disassembled)
null_circulators()
/obj/machinery/power/thermoelectric_generator/update_overlays()
. = ..()
if(machine_stat & (NOPOWER|BROKEN))
return
var/level = min(round(lastgenlev / 100000), 11)
if(level)
. += mutable_appearance('icons/obj/machines/engine/other.dmi', "[base_icon_state]-op[level]")
if(hot_circ && cold_circ)
. += "[base_icon_state]-oc[last_pressure_overlay]"
/obj/machinery/power/thermoelectric_generator/wrench_act(mob/living/user, obj/item/tool)
if(!panel_open)
balloon_alert(user, "open the panel!")
return
set_anchored(!anchored)
tool.play_tool_sound(src)
if(anchored)
connect_to_network()
else
null_circulators()
balloon_alert(user, "[anchored ? "secure" : "unsecure"]")
return TRUE
/obj/machinery/power/thermoelectric_generator/multitool_act(mob/living/user, obj/item/tool)
. = ..()
if(!anchored)
return
find_circulators()
balloon_alert(user, "circulators updated")
return TRUE
/obj/machinery/power/thermoelectric_generator/screwdriver_act(mob/user, obj/item/tool)
if(!anchored)
balloon_alert(user, "anchor it down!")
return
toggle_panel_open()
tool.play_tool_sound(src)
balloon_alert(user, "panel [panel_open ? "open" : "closed"]")
return TRUE
/obj/machinery/power/thermoelectric_generator/crowbar_act(mob/living/user, obj/item/tool)
default_deconstruction_crowbar(tool)
return TRUE
/obj/machinery/power/thermoelectric_generator/process()
//Setting this number higher just makes the change in power output slower, it doesnt actualy reduce power output cause **math**
var/power_output = round(lastgen / 10)
add_avail(power_output)
lastgenlev = power_output
lastgen -= power_output
/obj/machinery/power/thermoelectric_generator/process_atmos()
if(!cold_circ || !hot_circ)
return
if(!powernet)
return
var/datum/gas_mixture/cold_air = cold_circ.return_transfer_air()
var/datum/gas_mixture/hot_air = hot_circ.return_transfer_air()
if(cold_air && hot_air)
var/cold_air_heat_capacity = cold_air.heat_capacity()
var/hot_air_heat_capacity = hot_air.heat_capacity()
var/delta_temperature = hot_air.temperature - cold_air.temperature
if(delta_temperature > 0 && cold_air_heat_capacity > 0 && hot_air_heat_capacity > 0)
var/efficiency = TEG_EFFICIENCY
var/energy_transfer = delta_temperature*hot_air_heat_capacity*cold_air_heat_capacity/(hot_air_heat_capacity+cold_air_heat_capacity)
var/heat = energy_transfer*(1-efficiency)
lastgen += energy_transfer*efficiency
hot_air.temperature = hot_air.temperature - energy_transfer/hot_air_heat_capacity
cold_air.temperature = cold_air.temperature + heat/cold_air_heat_capacity
if(hot_air)
var/datum/gas_mixture/hot_circ_air1 = hot_circ.airs[1]
hot_circ_air1.merge(hot_air)
if(cold_air)
var/datum/gas_mixture/cold_circ_air1 = cold_circ.airs[1]
cold_circ_air1.merge(cold_air)
var/current_pressure = "[cold_circ?.last_pressure_delta > 0 ? "1" : "0"][hot_circ?.last_pressure_delta > 0 ? "1" : "0"]"
if(current_pressure != last_pressure_overlay)
//this requires an update to overlays.
last_pressure_overlay = current_pressure
update_appearance(UPDATE_ICON)
/obj/machinery/power/thermoelectric_generator/ui_interact(mob/user, datum/tgui/ui)
ui = SStgui.try_update_ui(user, src, ui)
if(!ui)
ui = new(user, src, "ThermoElectricGenerator", name)
ui.open()
/obj/machinery/power/thermoelectric_generator/ui_data(mob/user)
var/list/data = list()
data["error_message"] = null
if(!powernet)
data["error_message"] = "Unable to connect to the power network!"
return data
if(!cold_circ && !hot_circ)
data["error_message"] = "Unable to locate any parts! Multitool the machine to sync to nearby parts."
return data
if(!cold_circ)
data["error_message"] = "Unable to locate cold circulator!"
return data
if(!hot_circ)
data["error_message"] = "Unable to locate hot circulator!"
return data
var/datum/gas_mixture/cold_circ_air1 = cold_circ.airs[1]
var/datum/gas_mixture/cold_circ_air2 = cold_circ.airs[2]
var/datum/gas_mixture/hot_circ_air1 = hot_circ.airs[1]
var/datum/gas_mixture/hot_circ_air2 = hot_circ.airs[2]
data["last_power_output"] = display_power(lastgenlev)
var/list/cold_data = list()
cold_data["temperature_inlet"] = round(cold_circ_air2.temperature, 0.1)
cold_data["temperature_outlet"] = round(cold_circ_air1.temperature, 0.1)
cold_data["pressure_inlet"] = round(cold_circ_air2.return_pressure(), 0.1)
cold_data["pressure_outlet"] = round(cold_circ_air1.return_pressure(), 0.1)
data["cold_data"] = list(cold_data)
var/list/hot_data = list()
hot_data["temperature_inlet"] = round(hot_circ_air2.temperature, 0.1)
hot_data["temperature_outlet"] = round(hot_circ_air1.temperature, 0.1)
hot_data["pressure_inlet"] = round(hot_circ_air2.return_pressure(), 0.1)
hot_data["pressure_outlet"] = round(hot_circ_air1.return_pressure(), 0.1)
data["hot_data"] = list(hot_data)
return data
///Finds and connects nearby valid circulators to the machine, nulling out previous ones.
/obj/machinery/power/thermoelectric_generator/proc/find_circulators()
null_circulators()
var/list/valid_circulators = list()
if(dir & (NORTH|SOUTH))
var/obj/machinery/atmospherics/components/binary/circulator/east_circulator = locate() in get_step(src, EAST)
if(east_circulator && east_circulator.dir == WEST)
valid_circulators += east_circulator
var/obj/machinery/atmospherics/components/binary/circulator/west_circulator = locate() in get_step(src, WEST)
if(west_circulator && west_circulator.dir == EAST)
valid_circulators += west_circulator
else
var/obj/machinery/atmospherics/components/binary/circulator/north_circulator = locate() in get_step(src, NORTH)
if(north_circulator && north_circulator.dir == SOUTH)
valid_circulators += north_circulator
var/obj/machinery/atmospherics/components/binary/circulator/south_circulator = locate() in get_step(src, SOUTH)
if(south_circulator && south_circulator.dir == NORTH)
valid_circulators += south_circulator
if(!valid_circulators.len)
return
for(var/obj/machinery/atmospherics/components/binary/circulator/circulators as anything in valid_circulators)
if(circulators.mode == CIRCULATOR_COLD && !cold_circ)
cold_circ = circulators
circulators.generator = src
continue
if(circulators.mode == CIRCULATOR_HOT && !hot_circ)
hot_circ = circulators
circulators.generator = src
///Removes hot and cold circulators from the generator, nulling them.
/obj/machinery/power/thermoelectric_generator/proc/null_circulators()
if(hot_circ)
hot_circ.generator = null
hot_circ = null
if(cold_circ)
cold_circ.generator = null
cold_circ = null
#undef TEG_EFFICIENCY
Skyrat removal END
*/