mirror of
https://github.com/Bubberstation/Bubberstation.git
synced 2025-12-22 23:51:55 +00:00
This tracks the seconds per tick of a subsystem, however note that it is not completely accurate, as subsystems can be delayed, however it's useful to have this number as a multiplier or ratio, so that if in future someone changes the subsystem wait time code correctly adjusts how fast it applies effects regexes used git grep --files-with-matches --name-only 'DT_PROB' | xargs -l sed -i 's/DT_PROB/SPT_PROB/g' git grep --files-with-matches --name-only 'delta_time' | xargs -l sed -i 's/delta_time/seconds_per_tick/g'
61 lines
1.9 KiB
Plaintext
61 lines
1.9 KiB
Plaintext
/datum/computer_file/program/alarm_monitor
|
|
filename = "alarmmonitor"
|
|
filedesc = "Canary"
|
|
category = PROGRAM_CATEGORY_ENGI
|
|
ui_header = "alarm_green.gif"
|
|
program_icon_state = "alert-green"
|
|
extended_desc = "This program provides visual interface for a station's alarm system."
|
|
requires_ntnet = 1
|
|
size = 4
|
|
tgui_id = "NtosStationAlertConsole"
|
|
program_icon = "bell"
|
|
/// If there is any station alert
|
|
var/has_alert = FALSE
|
|
/// Station alert datum for showing alerts UI
|
|
var/datum/station_alert/alert_control
|
|
|
|
/datum/computer_file/program/alarm_monitor/on_install()
|
|
. = ..()
|
|
//We want to send an alarm if we're in one of the mining home areas
|
|
//Or if we're on station. Otherwise, die.
|
|
var/list/allowed_areas = GLOB.the_station_areas + typesof(/area/mine)
|
|
alert_control = new(computer, list(ALARM_ATMOS, ALARM_FIRE, ALARM_POWER), listener_areas = allowed_areas)
|
|
RegisterSignals(alert_control.listener, list(COMSIG_ALARM_LISTENER_TRIGGERED, COMSIG_ALARM_LISTENER_CLEARED), PROC_REF(update_alarm_display))
|
|
|
|
/datum/computer_file/program/alarm_monitor/Destroy()
|
|
QDEL_NULL(alert_control)
|
|
return ..()
|
|
|
|
/datum/computer_file/program/alarm_monitor/process_tick(seconds_per_tick)
|
|
..()
|
|
|
|
if(has_alert)
|
|
program_icon_state = "alert-red"
|
|
ui_header = "alarm_red.gif"
|
|
update_computer_icon()
|
|
else
|
|
if(!has_alert)
|
|
program_icon_state = "alert-green"
|
|
ui_header = "alarm_green.gif"
|
|
update_computer_icon()
|
|
return 1
|
|
|
|
/datum/computer_file/program/alarm_monitor/ui_data(mob/user)
|
|
var/list/data = list()
|
|
data += alert_control.ui_data(user)
|
|
return data
|
|
|
|
/datum/computer_file/program/alarm_monitor/proc/update_alarm_display()
|
|
SIGNAL_HANDLER
|
|
has_alert = FALSE
|
|
if(length(alert_control.listener.alarms))
|
|
has_alert = TRUE
|
|
|
|
/datum/computer_file/program/alarm_monitor/on_start(mob/user)
|
|
. = ..(user)
|
|
GLOB.alarmdisplay += src
|
|
|
|
/datum/computer_file/program/alarm_monitor/kill_program(forced = FALSE)
|
|
GLOB.alarmdisplay -= src
|
|
return ..()
|