Files
Bubberstation/code/controllers/subsystem/nightshift.dm
SkyratBot 761cdc3d20 [MIRROR] Station announcements cleanup [MDB IGNORE] (#24792)
* Station announcements cleanup

* Fix diffs

* Space indentation

* skyrat edits

---------

Co-authored-by: lessthanthree <83487515+lessthnthree@users.noreply.github.com>
Co-authored-by: Giz <13398309+vinylspiders@users.noreply.github.com>
2023-11-05 01:58:16 -05:00

67 lines
2.4 KiB
Plaintext

SUBSYSTEM_DEF(nightshift)
name = "Night Shift"
wait = 10 MINUTES
var/nightshift_active = FALSE
var/nightshift_start_time = 702000 //7:30 PM, station time
var/nightshift_end_time = 270000 //7:30 AM, station time
var/nightshift_first_check = 30 SECONDS
var/high_security_mode = FALSE
var/list/currentrun
/datum/controller/subsystem/nightshift/Initialize()
if(!CONFIG_GET(flag/enable_night_shifts))
can_fire = FALSE
return SS_INIT_SUCCESS
/datum/controller/subsystem/nightshift/fire(resumed = FALSE)
if(resumed)
update_nightshift(resumed = TRUE)
return
if(world.time - SSticker.round_start_time < nightshift_first_check)
return
check_nightshift()
/datum/controller/subsystem/nightshift/proc/announce(message)
priority_announce(
text = message,
sound = 'sound/misc/notice2.ogg',
sender_override = "Automated Lighting System Announcement",
color_override = "grey",
)
/datum/controller/subsystem/nightshift/proc/check_nightshift()
var/emergency = SSsecurity_level.get_current_level_as_number() >= SEC_LEVEL_RED
var/announcing = TRUE
var/time = station_time()
var/night_time = (time < nightshift_end_time) || (time > nightshift_start_time)
if(high_security_mode != emergency)
high_security_mode = emergency
if(night_time)
announcing = FALSE
if(!emergency)
announce("Restoring night lighting configuration to normal operation.")
else
announce("Disabling night lighting: Station is in a state of emergency.")
if(emergency)
night_time = FALSE
if(nightshift_active != night_time)
update_nightshift(night_time, announcing)
/datum/controller/subsystem/nightshift/proc/update_nightshift(active, announce = TRUE, resumed = FALSE, forced = FALSE)
if(!resumed)
currentrun = SSmachines.get_machines_by_type_and_subtypes(/obj/machinery/power/apc)
nightshift_active = active
if(announce)
if (active)
announce("Good evening, crew. To reduce power consumption and stimulate the circadian rhythms of some species, all of the lights aboard the station have been dimmed for the night.")
else
announce("Good morning, crew. As it is now day time, all of the lights aboard the station have been restored to their former brightness.")
for(var/obj/machinery/power/apc/APC as anything in currentrun)
currentrun -= APC
if (APC.area && (APC.area.type in GLOB.the_station_areas))
APC.set_nightshift(nightshift_active)
if(MC_TICK_CHECK && !forced) // subsystem will be in state SS_IDLE if forced by an admin
return