mirror of
https://github.com/Bubberstation/Bubberstation.git
synced 2025-12-26 01:22:03 +00:00
* Fix APC related issues (#77005) ## About The Pull Request Fixes a bunch of stuff broken by #76822, including APC control console, malf blackout ability, shunted malf pinpointing, Admin APC recharge and others. ## Why It's Good For The Game Yes. ## Changelog :cl:Thebleh fix: Fixed several APC related issues. /🆑 * Fix APC related issues --------- Co-authored-by: thebleh <43266738+rdragan@users.noreply.github.com>
62 lines
2.4 KiB
Plaintext
62 lines
2.4 KiB
Plaintext
SUBSYSTEM_DEF(nightshift)
|
|
name = "Night Shift"
|
|
wait = 10 MINUTES
|
|
|
|
var/nightshift_active = FALSE
|
|
var/nightshift_start_time = 702000 //7:30 PM, station time
|
|
var/nightshift_end_time = 270000 //7:30 AM, station time
|
|
var/nightshift_first_check = 30 SECONDS
|
|
|
|
var/high_security_mode = FALSE
|
|
var/list/currentrun
|
|
|
|
/datum/controller/subsystem/nightshift/Initialize()
|
|
if(!CONFIG_GET(flag/enable_night_shifts))
|
|
can_fire = FALSE
|
|
return SS_INIT_SUCCESS
|
|
|
|
/datum/controller/subsystem/nightshift/fire(resumed = FALSE)
|
|
if(resumed)
|
|
update_nightshift(resumed = TRUE)
|
|
return
|
|
if(world.time - SSticker.round_start_time < nightshift_first_check)
|
|
return
|
|
check_nightshift()
|
|
|
|
/datum/controller/subsystem/nightshift/proc/announce(message)
|
|
priority_announce(message, sound='sound/misc/notice2.ogg', sender_override="Automated Lighting System Announcement")
|
|
|
|
/datum/controller/subsystem/nightshift/proc/check_nightshift()
|
|
var/emergency = SSsecurity_level.get_current_level_as_number() >= SEC_LEVEL_RED
|
|
var/announcing = TRUE
|
|
var/time = station_time()
|
|
var/night_time = (time < nightshift_end_time) || (time > nightshift_start_time)
|
|
if(high_security_mode != emergency)
|
|
high_security_mode = emergency
|
|
if(night_time)
|
|
announcing = FALSE
|
|
if(!emergency)
|
|
announce("Restoring night lighting configuration to normal operation.")
|
|
else
|
|
announce("Disabling night lighting: Station is in a state of emergency.")
|
|
if(emergency)
|
|
night_time = FALSE
|
|
if(nightshift_active != night_time)
|
|
update_nightshift(night_time, announcing)
|
|
|
|
/datum/controller/subsystem/nightshift/proc/update_nightshift(active, announce = TRUE, resumed = FALSE, forced = FALSE)
|
|
if(!resumed)
|
|
currentrun = SSmachines.get_machines_by_type_and_subtypes(/obj/machinery/power/apc)
|
|
nightshift_active = active
|
|
if(announce)
|
|
if (active)
|
|
announce("Good evening, crew. To reduce power consumption and stimulate the circadian rhythms of some species, all of the lights aboard the station have been dimmed for the night.")
|
|
else
|
|
announce("Good morning, crew. As it is now day time, all of the lights aboard the station have been restored to their former brightness.")
|
|
for(var/obj/machinery/power/apc/APC as anything in currentrun)
|
|
currentrun -= APC
|
|
if (APC.area && (APC.area.type in GLOB.the_station_areas))
|
|
APC.set_nightshift(nightshift_active)
|
|
if(MC_TICK_CHECK && !forced) // subsystem will be in state SS_IDLE if forced by an admin
|
|
return
|