/obj/machinery/power/apc/get_cell()
|
|
return cell
|
|
|
|
/obj/machinery/power/apc/connect_to_network()
|
|
//Override because the APC does not directly connect to the network; it goes through a terminal.
|
|
//The terminal is what the power computer looks for anyway.
|
|
if(terminal)
|
|
terminal.connect_to_network()
|
|
|
|
/obj/machinery/power/apc/proc/make_terminal()
|
|
// create a terminal object at the same position as original turf loc
|
|
// wires will attach to this
|
|
terminal = new/obj/machinery/power/terminal(loc)
|
|
terminal.setDir(dir)
|
|
terminal.master = src
|
|
|
|
/obj/machinery/power/apc/proc/toggle_nightshift_lights(mob/user)
|
|
if(low_power_nightshift_lights)
|
|
balloon_alert(user, "power is too low!")
|
|
return
|
|
if(last_nightshift_switch > world.time - 10 SECONDS) //~10 seconds between each toggle to prevent spamming
|
|
balloon_alert(user, "night breaker is cycling!")
|
|
return
|
|
last_nightshift_switch = world.time
|
|
set_nightshift(!nightshift_lights)
|
|
|
|
/obj/machinery/power/apc/proc/update()
|
|
if(operating && !shorted && !failure_timer)
|
|
area.power_light = (lighting > APC_CHANNEL_AUTO_OFF)
|
|
area.power_equip = (equipment > APC_CHANNEL_AUTO_OFF)
|
|
area.power_environ = (environ > APC_CHANNEL_AUTO_OFF)
|
|
playsound(src.loc, 'sound/machines/terminal_on.ogg', 50, FALSE)
|
|
else
|
|
area.power_light = FALSE
|
|
area.power_equip = FALSE
|
|
area.power_environ = FALSE
|
|
playsound(src.loc, 'sound/machines/terminal_off.ogg', 50, FALSE)
|
|
area.power_change()
|
|
|
|
/obj/machinery/power/apc/proc/toggle_breaker(mob/user)
|
|
if(!is_operational || failure_timer)
|
|
return
|
|
operating = !operating
|
|
add_hiddenprint(user)
|
|
user.log_message("turned [operating ? "on" : "off"] the [src]", LOG_GAME)
|
|
update()
|
|
update_appearance()
|
|
|
|
/obj/machinery/power/apc/surplus()
|
|
if(terminal)
|
|
return terminal.surplus()
|
|
return 0
|
|
|
|
/obj/machinery/power/apc/add_load(amount)
|
|
if(terminal?.powernet)
|
|
terminal.add_load(amount)
|
|
|
|
/obj/machinery/power/apc/avail(amount)
|
|
if(terminal)
|
|
return terminal.avail(amount)
|
|
return 0
|
|
|
|
/**
|
|
* Returns the new status value for an APC channel.
|
|
*
|
|
* // val 0=off, 1=off(auto) 2=on 3=on(auto)
|
|
* // on 0=off, 1=on, 2=autooff
|
|
* TODO: Make this use bitflags instead. It should take at most three lines, but it's out of scope for now.
|
|
*
|
|
* Arguments:
|
|
* - val: The current status of the power channel.
|
|
* - [APC_CHANNEL_OFF]: The APCs channel has been manually set to off. This channel will not automatically change.
|
|
* - [APC_CHANNEL_AUTO_OFF]: The APCs channel is running on automatic and is currently off. Can be automatically set to [APC_CHANNEL_AUTO_ON].
|
|
* - [APC_CHANNEL_ON]: The APCs channel has been manually set to on. This will be automatically changed only if the APC runs completely out of power or is disabled.
|
|
* - [APC_CHANNEL_AUTO_ON]: The APCs channel is running on automatic and is currently on. Can be automatically set to [APC_CHANNEL_AUTO_OFF].
|
|
* - on: An enum dictating how to change the channel's status.
|
|
* - [AUTOSET_FORCE_OFF]: The APC forces the channel to turn off. This includes manually set channels.
|
|
* - [AUTOSET_ON]: The APC allows automatic channels to turn back on.
|
|
* - [AUTOSET_OFF]: The APC turns automatic channels off.
|
|
*/
|
|
/obj/machinery/power/apc/proc/autoset(val, on)
|
|
switch(on)
|
|
if(AUTOSET_FORCE_OFF)
|
|
if(val == APC_CHANNEL_ON) // if on, return off
|
|
return APC_CHANNEL_OFF
|
|
else if(val == APC_CHANNEL_AUTO_ON) // if auto-on, return auto-off
|
|
return APC_CHANNEL_AUTO_OFF
|
|
if(AUTOSET_ON)
|
|
if(val == APC_CHANNEL_AUTO_OFF) // if auto-off, return auto-on
|
|
return APC_CHANNEL_AUTO_ON
|
|
if(AUTOSET_OFF)
|
|
if(val == APC_CHANNEL_AUTO_ON) // if auto-on, return auto-off
|
|
return APC_CHANNEL_AUTO_OFF
|
|
return val
|
|
|
|
/**
|
|
* Used by external forces to set the APCs channel status's.
|
|
*
|
|
* Arguments:
|
|
* - val: The desired value of the subsystem:
|
|
* - 1: Manually sets the APCs channel to be [APC_CHANNEL_OFF].
|
|
* - 2: Manually sets the APCs channel to be [APC_CHANNEL_AUTO_ON]. If the APC doesn't have any power this defaults to [APC_CHANNEL_OFF] instead.
|
|
* - 3: Sets the APCs channel to be [APC_CHANNEL_AUTO_ON]. If the APC doesn't have enough power this defaults to [APC_CHANNEL_AUTO_OFF] instead.
|
|
*/
|
|
/obj/machinery/power/apc/proc/setsubsystem(val)
|
|
if(cell && cell.charge > 0)
|
|
return (val == 1) ? APC_CHANNEL_OFF : val
|
|
if(val == 3)
|
|
return APC_CHANNEL_AUTO_OFF
|
|
return APC_CHANNEL_OFF
|
|
|
|
/obj/machinery/power/apc/disconnect_terminal()
|
|
if(terminal)
|
|
terminal.master = null
|
|
terminal = null
|
|
|
|
/obj/machinery/power/apc/proc/energy_fail(duration)
|
|
for(var/obj/machinery/failing_machine in area.contents)
|
|
if(failing_machine.critical_machine)
|
|
return
|
|
|
|
for(var/mob/living/silicon/ai as anything in GLOB.ai_list)
|
|
if(get_area(ai) == area)
|
|
return
|
|
|
|
failure_timer = max(failure_timer, round(duration))
|
|
update()
|
|
queue_icon_update()
|
|
|
|
/obj/machinery/power/apc/proc/set_nightshift(on)
|
|
set waitfor = FALSE
|
|
if(low_power_nightshift_lights && !on)
|
|
return
|
|
if(nightshift_lights == on)
|
|
return //no change
|
|
nightshift_lights = on
|
|
for(var/obj/machinery/light/night_light in area)
|
|
if(night_light.nightshift_allowed)
|
|
night_light.nightshift_enabled = nightshift_lights
|
|
night_light.update(FALSE)
|
|
CHECK_TICK
|