mirror of
https://github.com/Bubberstation/Bubberstation.git
synced 2026-01-10 17:04:36 +00:00
Fixed motion alarms instantly triggering and de/un/re/triggering The relevant changes are in motion.dm and ai_monitored.dm. Everything else is a replacement of /area/turret_protected -> /area/ai_monitored/turret_protected which is why this PR is a bitch
81 lines
2.4 KiB
Plaintext
81 lines
2.4 KiB
Plaintext
/proc/power_failure()
|
|
priority_announce("Abnormal activity detected in [station_name()]'s powernet. As a precautionary measure, the station's power will be shut off for an indeterminate duration.", "Critical Power Failure", 'sound/AI/poweroff.ogg')
|
|
for(var/obj/machinery/power/smes/S in machines)
|
|
if(istype(get_area(S), /area/ai_monitored/turret_protected) || S.z != ZLEVEL_STATION)
|
|
continue
|
|
S.charge = 0
|
|
S.output_level = 0
|
|
S.output_attempt = 0
|
|
S.update_icon()
|
|
S.power_change()
|
|
|
|
var/list/skipped_areas = list(/area/engine/engineering, /area/ai_monitored/turret_protected/ai)
|
|
|
|
for(var/area/A in world)
|
|
if( !A.requires_power || A.always_unpowered )
|
|
continue
|
|
|
|
var/skip = 0
|
|
for(var/area_type in skipped_areas)
|
|
if(istype(A,area_type))
|
|
skip = 1
|
|
break
|
|
if(A.contents)
|
|
for(var/atom/AT in A.contents)
|
|
if(AT.z != ZLEVEL_STATION) //Only check one, it's enough.
|
|
skip = 1
|
|
break
|
|
if(skip) continue
|
|
A.power_light = 0
|
|
A.power_equip = 0
|
|
A.power_environ = 0
|
|
A.power_change()
|
|
|
|
for(var/obj/machinery/power/apc/C in apcs_list)
|
|
if(C.cell && C.z == ZLEVEL_STATION)
|
|
var/area/A = get_area(C)
|
|
|
|
var/skip = 0
|
|
for(var/area_type in skipped_areas)
|
|
if(istype(A,area_type))
|
|
skip = 1
|
|
break
|
|
if(skip) continue
|
|
|
|
C.cell.charge = 0
|
|
|
|
/proc/power_restore()
|
|
|
|
priority_announce("Power has been restored to [station_name()]. We apologize for the inconvenience.", "Power Systems Nominal", 'sound/AI/poweron.ogg')
|
|
for(var/obj/machinery/power/apc/C in machines)
|
|
if(C.cell && C.z == ZLEVEL_STATION)
|
|
C.cell.charge = C.cell.maxcharge
|
|
C.failure_timer = 0
|
|
for(var/obj/machinery/power/smes/S in machines)
|
|
if(S.z != ZLEVEL_STATION)
|
|
continue
|
|
S.charge = S.capacity
|
|
S.output_level = S.output_level_max
|
|
S.output_attempt = 1
|
|
S.update_icon()
|
|
S.power_change()
|
|
for(var/area/A in world)
|
|
if(!istype(A, /area/space) && !istype(A, /area/shuttle) && !istype(A,/area/arrival))
|
|
A.power_light = 1
|
|
A.power_equip = 1
|
|
A.power_environ = 1
|
|
A.power_change()
|
|
|
|
/proc/power_restore_quick()
|
|
|
|
priority_announce("All SMESs on [station_name()] have been recharged. We apologize for the inconvenience.", "Power Systems Nominal", 'sound/AI/poweron.ogg')
|
|
for(var/obj/machinery/power/smes/S in machines)
|
|
if(S.z != ZLEVEL_STATION)
|
|
continue
|
|
S.charge = S.capacity
|
|
S.output_level = S.output_level_max
|
|
S.output_attempt = 1
|
|
S.update_icon()
|
|
S.power_change()
|
|
|