mirror of
https://github.com/Bubberstation/Bubberstation.git
synced 2026-01-01 20:42:08 +00:00
* Redoes how alarms are handled, moves their behavior to datums * a Co-authored-by: LemonInTheDark <58055496+LemonInTheDark@users.noreply.github.com> Co-authored-by: Gandalf <jzo123@hotmail.com>
75 lines
2.1 KiB
Plaintext
75 lines
2.1 KiB
Plaintext
/datum/wires/airalarm
|
|
holder_type = /obj/machinery/airalarm
|
|
proper_name = "Air Alarm"
|
|
|
|
/datum/wires/airalarm/New(atom/holder)
|
|
wires = list(
|
|
WIRE_POWER,
|
|
WIRE_IDSCAN, WIRE_AI,
|
|
WIRE_PANIC, WIRE_ALARM
|
|
)
|
|
add_duds(3)
|
|
..()
|
|
|
|
/datum/wires/airalarm/interactable(mob/user)
|
|
if(!..())
|
|
return FALSE
|
|
var/obj/machinery/airalarm/A = holder
|
|
if(A.panel_open && A.buildstage == 2)
|
|
return TRUE
|
|
|
|
/datum/wires/airalarm/get_status()
|
|
var/obj/machinery/airalarm/A = holder
|
|
var/list/status = list()
|
|
status += "The interface light is [A.locked ? "red" : "green"]."
|
|
status += "The short indicator is [A.shorted ? "lit" : "off"]."
|
|
status += "The AI connection light is [!A.aidisabled ? "on" : "off"]."
|
|
return status
|
|
|
|
/datum/wires/airalarm/on_pulse(wire)
|
|
var/obj/machinery/airalarm/A = holder
|
|
switch(wire)
|
|
if(WIRE_POWER) // Short out for a long time.
|
|
if(!A.shorted)
|
|
A.shorted = TRUE
|
|
A.update_appearance()
|
|
addtimer(CALLBACK(A, /obj/machinery/airalarm.proc/reset, wire), 1200)
|
|
if(WIRE_IDSCAN) // Toggle lock.
|
|
A.locked = !A.locked
|
|
if(WIRE_AI) // Disable AI control for a while.
|
|
if(!A.aidisabled)
|
|
A.aidisabled = TRUE
|
|
addtimer(CALLBACK(A, /obj/machinery/airalarm.proc/reset, wire), 100)
|
|
if(WIRE_PANIC) // Toggle panic siphon.
|
|
if(!A.shorted)
|
|
if(A.mode == 1) // AALARM_MODE_SCRUB
|
|
A.mode = 3 // AALARM_MODE_PANIC
|
|
else
|
|
A.mode = 1 // AALARM_MODE_SCRUB
|
|
A.apply_mode(usr)
|
|
if(WIRE_ALARM) // Clear alarms.
|
|
if(A.alarm_manager.clear_alarm(ALARM_ATMOS))
|
|
A.post_alert(0)
|
|
A.update_appearance()
|
|
|
|
/datum/wires/airalarm/on_cut(wire, mend)
|
|
var/obj/machinery/airalarm/A = holder
|
|
switch(wire)
|
|
if(WIRE_POWER) // Short out forever.
|
|
A.shock(usr, 50)
|
|
A.shorted = !mend
|
|
A.update_appearance()
|
|
if(WIRE_IDSCAN)
|
|
if(!mend)
|
|
A.locked = TRUE
|
|
if(WIRE_AI)
|
|
A.aidisabled = mend // Enable/disable AI control.
|
|
if(WIRE_PANIC) // Force panic syphon on.
|
|
if(!mend && !A.shorted)
|
|
A.mode = 3 // AALARM_MODE_PANIC
|
|
A.apply_mode(usr)
|
|
if(WIRE_ALARM) // Post alarm.
|
|
if(A.alarm_manager.send_alarm(ALARM_ATMOS))
|
|
A.post_alert(2)
|
|
A.update_appearance()
|