mirror of
https://github.com/Bubberstation/Bubberstation.git
synced 2025-12-14 19:51:59 +00:00
## About The Pull Request
# More robust logging
## Ore silo logs have now been refactored in the UI to display:
- Number of sheets is now the relative unit when displaying a given log.
- Instead of `100 iron` being displayed when removing one sheet, it just
says `1 iron`
- Instead of `25 iron` being displayed when using a quarter sheet, it
just says `0.25 iron`
- All information from ID_DATA(log_user) now sent to tgui backend
- The items rendered to ore silo users are:
- Name on ID, job on ID
- If the ID's bank account (if one is registered) is one of the ore
silo's banned users
- If the user for a given entry was wearing a chameleon card, they will
always appear unbanned
- NOTE: The bank account ID # is (currently) not shown to players using
the ore silo.
- Full log information is rendered within a dropdown; the dropdown
one-liner shows
- Action (deposit, eject, item created)
- Amount (deposit/eject? amount of material used. item created? number
of items created.)
- Either name of material (if deposit/eject) or the name of items
crafted
- The name of the user who performed a given operation (if wearing an
unbanned ID) or ID_READ_FAILURE (if ore silo ID requirement has been
disabled and the person is not wearing an ID)
- As name, but instead, the job of the ID (or ID_READ_FAILURE)

# Access control improvements
## Single-user bans
- Anyone with QM access (not silicons) can now ban/unban a user from a
given log from using the ore silo
- Bans are associated to bank account IDs.
- Wearers of chameleon cards bypass any ban restrictions.
- Anyone with QM access on their worn card bypasses ban restrictions.
- Silicons bypass ban restrictions.
- QM access requirement is removed if the ore silo is emagged.
- Silicons can ban/unban people if the ore silo is emagged.
## Worn ID requirement
- Enabled at roundstart, can be disabled by anyone with QM access (not
silicons)
- If enabled, you must be wearing an ID with a bank account associated
to it to use ore silo materials.
- Wearers of chameleon cards bypass this restriction (so-called ID
requirement free thinkers wearing chameleon ID cards)
- QM access requirement to toggle removed if emagged.
- Silicons can toggle this on/off if the ore silo is emagged.
# Access control radio notifications
## Access control operations reported on the radio
- Any operations for access control are reported on radio channels.
- Currently, the policy is always the default.
- In the future, the ore silo UI will allow the quartermaster to modify
what operations are reported on what channels (petty QM broadcasting ban
reports on Common)
- Current default policy:
- Reported on COMMON channel:
- Anyone but the Captain attempts to ban someone with QM access from the
ore silo (nice try dumbass)
- Ore silo ID requirement toggling
- Reported on COMMAND channel:
- Common channel reports.
- Per-user banning/unbanning.
- Anyone without QM access attempts to ban/unban someone.
- Anyone without QM access attempts to toggle the restriction for ID.
- Silicons attempting to tamper with the ID requirement restriction
- Silicons attempting to tamper with the ban/unbanned user list
- A ban attempt failing because a given log entry had a user with no
bank ID.
- Reported on SECURITY channel:
- Common channel reports.
- Per-user banning/unbanning.
- Anyone without QM access tampering with the silo.
- Reported on SUPPLY channel:
- Command channel reports.
- Reporting to the radio is disabled if the ore silo is emagged.
## Modifications to the remote_materials component
- Strictly encompass the behavior for connecting/disconnecting ore silos
to material receptacles (RCDs, machines, etc) into procs on the
component, instead of handling it all over the place
## Why It's Good For The Game
Gives people with ore silo access more fine grained control over ore
silo use without having to resort to heavy-handed fabricator lockouts
Makes the logging on the ore silo more robust so we can make sure we
kill the right Roboticist for using all the materials
Offers an avenue for sidestepping all of this with a chameleon card or
emag if a given traitor (organic or otherwise) is particularly opposed
to DRM mats.
https://github.com/user-attachments/assets/effd2c63-509c-4d33-992f-837a0d62b935
## Changelog
🆑 Bisar
add: The ore silo has had a significant expansion to its logging
capabilities.
add: The ore silo now allows any ID with Quartermaster access (NOT
SILICONS!) to ban/unban specific users from the silo.
add: The ore silo now has a toggle (on by default) that a user of ore
silo materials has an ID with an associated bank account. This can be
toggled by anyone with Quartermaster access (NOT SILICONS!)
add: NanoTrasen discounts any reports that Syndicate contraband
(cryptographic sequencer, agent card) can be used to circumvent any
protocols instituted on the ore silo access control routines.
add: The ore silo now announces operations to ban/unban users and
enable/disable ID requirements on radio channels (check the Github for
actions reported to what channels.)
add: The tgui interface for ore silo log entries has been reworked.
refactor: The code for logging a given access to ore silo materials has
been significantly refactored.
qol: Ore silo log entries now display materials spent in terms of sheets
rather than the obfuscated absolute-units previously display (1 iron
ejected instead of -100 iron, 0.25 used in a craft instead of -25 iron)
/🆑
767 lines
26 KiB
Plaintext
767 lines
26 KiB
Plaintext
/// A list of all integrated circuits
|
|
GLOBAL_LIST_EMPTY_TYPED(integrated_circuits, /obj/item/integrated_circuit)
|
|
|
|
/**
|
|
* # Integrated Circuitboard
|
|
*
|
|
* A circuitboard that holds components that work together
|
|
*
|
|
* Has a limited amount of power.
|
|
*/
|
|
/obj/item/integrated_circuit
|
|
name = "integrated circuit"
|
|
desc = "By inserting components and a cell into this, wiring them up, and putting them into a shell, anyone can pretend to be a programmer."
|
|
icon = 'icons/obj/devices/circuitry_n_data.dmi'
|
|
icon_state = "integrated_circuit"
|
|
inhand_icon_state = "electronic"
|
|
lefthand_file = 'icons/mob/inhands/items/devices_lefthand.dmi'
|
|
righthand_file = 'icons/mob/inhands/items/devices_righthand.dmi'
|
|
w_class = WEIGHT_CLASS_TINY
|
|
|
|
/// The name that appears on the shell.
|
|
var/display_name = ""
|
|
|
|
/// The max length of the name.
|
|
var/label_max_length = 24
|
|
|
|
/// The power of the integrated circuit
|
|
var/obj/item/stock_parts/power_store/cell
|
|
|
|
/// The shell that this circuitboard is attached to. Used by components.
|
|
var/atom/movable/shell
|
|
|
|
/// The attached components
|
|
var/list/obj/item/circuit_component/attached_components = list()
|
|
|
|
/// Whether the integrated circuit is on or not. Handled by the shell.
|
|
var/on = FALSE
|
|
|
|
/// Whether the integrated circuit is locked or not. Handled by the shell.
|
|
var/locked = FALSE
|
|
|
|
/// Whether the integrated circuit is admin only. Disables power usage and allows admin circuits to be attached, at the cost of making it inaccessible to regular users.
|
|
var/admin_only = FALSE
|
|
|
|
/// The ID that is authorized to unlock/lock the shell so that the circuit can/cannot be removed.
|
|
var/datum/weakref/owner_id
|
|
|
|
/// The current examined component. Used in IntegratedCircuit UI
|
|
var/datum/weakref/examined_component
|
|
|
|
/// Set by the shell. Holds the reference to the owner who inserted the component into the shell.
|
|
var/datum/weakref/inserter_mind
|
|
|
|
/// Variables stored on this integrated circuit, with a `variable_name = value` structure
|
|
var/list/datum/circuit_variable/circuit_variables = list()
|
|
|
|
/// Variables stored on this integrated circuit that can be set by a setter, with a `variable_name = value` structure
|
|
var/list/datum/circuit_variable/modifiable_circuit_variables = list()
|
|
|
|
/// List variables stored on this integrated circuit, with a `variable_name = value` structure
|
|
var/list/datum/circuit_variable/list_variables = list()
|
|
|
|
/// Assoc list variables stored on this integrated circuit, with a `variable_name = value` structure
|
|
var/list/datum/circuit_variable/assoc_list_variables = list()
|
|
|
|
/// The maximum amount of setters and getters a circuit can have
|
|
var/max_setters_and_getters = 30
|
|
|
|
/// The current setter and getter count the circuit has.
|
|
var/setter_and_getter_count = 0
|
|
|
|
/// X position of the examined_component
|
|
var/examined_rel_x = 0
|
|
|
|
/// Y position of the examined component
|
|
var/examined_rel_y = 0
|
|
|
|
/// The X position of the screen. Used for adding components
|
|
var/screen_x = 0
|
|
|
|
/// The Y position of the screen. Used for adding components.
|
|
var/screen_y = 0
|
|
|
|
/// The grid mode state for the circuit.
|
|
var/grid_mode = TRUE
|
|
|
|
/// The current size of the circuit.
|
|
var/current_size = 0
|
|
|
|
/// The current linked component printer. Lets you remotely print off circuit components and places them in the integrated circuit.
|
|
var/datum/weakref/linked_component_printer
|
|
|
|
/obj/item/integrated_circuit/Initialize(mapload)
|
|
. = ..()
|
|
|
|
GLOB.integrated_circuits += src
|
|
|
|
RegisterSignal(src, COMSIG_ATOM_USB_CABLE_TRY_ATTACH, PROC_REF(on_atom_usb_cable_try_attach))
|
|
|
|
/obj/item/integrated_circuit/loaded/Initialize(mapload)
|
|
. = ..()
|
|
set_cell(new /obj/item/stock_parts/power_store/cell/high(src))
|
|
|
|
/obj/item/integrated_circuit/Destroy()
|
|
for(var/obj/item/circuit_component/to_delete in attached_components)
|
|
remove_component(to_delete)
|
|
qdel(to_delete)
|
|
QDEL_LIST_ASSOC_VAL(circuit_variables)
|
|
QDEL_LIST_ASSOC_VAL(list_variables)
|
|
attached_components.Cut()
|
|
shell = null
|
|
examined_component = null
|
|
owner_id = null
|
|
QDEL_NULL(cell)
|
|
GLOB.integrated_circuits -= src
|
|
return ..()
|
|
|
|
/obj/item/integrated_circuit/examine(mob/user)
|
|
. = ..()
|
|
if(cell)
|
|
. += span_notice("The charge meter reads [cell ? round(cell.percent(), 1) : 0]%.")
|
|
else
|
|
. += span_notice("There is no power cell installed.")
|
|
|
|
/obj/item/integrated_circuit/drop_location()
|
|
if(shell)
|
|
return shell.drop_location()
|
|
return ..()
|
|
|
|
/**
|
|
* Sets the cell of the integrated circuit.
|
|
*
|
|
* Arguments:
|
|
* * cell_to_set - The new cell of the circuit. Can be null.
|
|
**/
|
|
/obj/item/integrated_circuit/proc/set_cell(obj/item/stock_parts/power_store/cell_to_set)
|
|
SEND_SIGNAL(src, COMSIG_CIRCUIT_SET_CELL, cell_to_set)
|
|
cell = cell_to_set
|
|
|
|
/**
|
|
* Sets the locked status of the integrated circuit.
|
|
*
|
|
* Arguments:
|
|
* * new_value - A boolean that determines if the circuit is locked or not.
|
|
**/
|
|
/obj/item/integrated_circuit/proc/set_locked(new_value)
|
|
SEND_SIGNAL(src, COMSIG_CIRCUIT_SET_LOCKED, new_value)
|
|
locked = new_value
|
|
|
|
/obj/item/integrated_circuit/attackby(obj/item/I, mob/living/user, list/modifiers, list/attack_modifiers)
|
|
. = ..()
|
|
if(istype(I, /obj/item/circuit_component))
|
|
add_component_manually(I, user)
|
|
return
|
|
|
|
if(istype(I, /obj/item/stock_parts/power_store/cell))
|
|
if(cell)
|
|
balloon_alert(user, "there already is a cell inside!")
|
|
return
|
|
if(!user.transferItemToLoc(I, src))
|
|
return
|
|
set_cell(I)
|
|
I.add_fingerprint(user)
|
|
user.visible_message(span_notice("[user] inserts a power cell into [src]."), span_notice("You insert the power cell into [src]."))
|
|
return
|
|
|
|
if(isidcard(I))
|
|
balloon_alert(user, "owner id set for [I]")
|
|
owner_id = WEAKREF(I)
|
|
return
|
|
|
|
if(I.tool_behaviour == TOOL_SCREWDRIVER)
|
|
if(!cell)
|
|
return
|
|
I.play_tool_sound(src)
|
|
user.visible_message(span_notice("[user] unscrews the power cell from [src]."), span_notice("You unscrew the power cell from [src]."))
|
|
cell.forceMove(drop_location())
|
|
set_cell(null)
|
|
return
|
|
|
|
/**
|
|
* Registers an movable atom as a shell
|
|
*
|
|
* No functionality is done here. This is so that input components
|
|
* can properly register any signals on the shell.
|
|
* Arguments:
|
|
* * new_shell - The new shell to register.
|
|
*/
|
|
/obj/item/integrated_circuit/proc/set_shell(atom/movable/new_shell)
|
|
remove_current_shell()
|
|
set_on(TRUE)
|
|
SEND_SIGNAL(src, COMSIG_CIRCUIT_SET_SHELL, new_shell)
|
|
shell = new_shell
|
|
RegisterSignal(shell, COMSIG_QDELETING, PROC_REF(remove_current_shell))
|
|
for(var/obj/item/circuit_component/attached_component as anything in attached_components)
|
|
attached_component.register_shell(shell)
|
|
// Their input ports may be updated with user values, but the outputs haven't updated
|
|
// because on is FALSE
|
|
attached_component.trigger_component()
|
|
|
|
/**
|
|
* Unregisters the current shell attached to this circuit.
|
|
*/
|
|
/obj/item/integrated_circuit/proc/remove_current_shell()
|
|
SIGNAL_HANDLER
|
|
if(!shell)
|
|
return
|
|
shell.name = initial(shell.name)
|
|
for(var/obj/item/circuit_component/attached_component as anything in attached_components)
|
|
attached_component.unregister_shell(shell)
|
|
UnregisterSignal(shell, COMSIG_QDELETING)
|
|
shell = null
|
|
set_on(FALSE)
|
|
SEND_SIGNAL(src, COMSIG_CIRCUIT_SHELL_REMOVED)
|
|
|
|
/**
|
|
* Sets the on status of the integrated circuit.
|
|
*
|
|
* Arguments:
|
|
* * new_value - A boolean that determines if the circuit is on or not.
|
|
**/
|
|
/obj/item/integrated_circuit/proc/set_on(new_value)
|
|
SEND_SIGNAL(src, COMSIG_CIRCUIT_SET_ON, new_value)
|
|
on = new_value
|
|
|
|
/**
|
|
* Used for checking if another component of to_check's type exists in the circuit.
|
|
* Introspects through modules.
|
|
*
|
|
* Arguments:
|
|
* * to_check - The component to check.
|
|
**/
|
|
/obj/item/integrated_circuit/proc/is_duplicate(obj/item/circuit_component/to_check)
|
|
for(var/component as anything in attached_components)
|
|
if(component == to_check)
|
|
continue
|
|
if(istype(component, to_check.type))
|
|
return TRUE
|
|
if(istype(component, /obj/item/circuit_component/module))
|
|
var/obj/item/circuit_component/module/module = component
|
|
for(var/module_component as anything in module.internal_circuit.attached_components)
|
|
if(module_component == to_check)
|
|
continue
|
|
if(istype(module_component, to_check.type))
|
|
return TRUE
|
|
return FALSE
|
|
|
|
/**
|
|
* Adds a component to the circuitboard
|
|
*
|
|
* Once the component is added, the ports can be attached to other components
|
|
*/
|
|
/obj/item/integrated_circuit/proc/add_component(obj/item/circuit_component/to_add, mob/living/user)
|
|
if(to_add.parent)
|
|
return FALSE
|
|
|
|
if(SEND_SIGNAL(src, COMSIG_CIRCUIT_ADD_COMPONENT, to_add, user) & COMPONENT_CANCEL_ADD_COMPONENT)
|
|
return FALSE
|
|
|
|
if(!to_add.add_to(src))
|
|
return FALSE
|
|
|
|
if(to_add.circuit_flags & CIRCUIT_NO_DUPLICATES)
|
|
if(is_duplicate(to_add))
|
|
to_chat(user, span_danger("You can't insert multiple instances of this component into the same circuit!"))
|
|
return FALSE
|
|
|
|
var/success = FALSE
|
|
if(user)
|
|
success = user.transferItemToLoc(to_add, src)
|
|
else
|
|
success = to_add.forceMove(src)
|
|
|
|
if(!success)
|
|
return FALSE
|
|
|
|
to_add.rel_x = rand(COMPONENT_MIN_RANDOM_POS, COMPONENT_MAX_RANDOM_POS) - screen_x
|
|
to_add.rel_y = rand(COMPONENT_MIN_RANDOM_POS, COMPONENT_MAX_RANDOM_POS) - screen_y
|
|
SEND_SIGNAL(to_add, COMSIG_CIRCUIT_COMPONENT_ADDED, src)
|
|
to_add.parent = src
|
|
attached_components += to_add
|
|
current_size += to_add.circuit_size
|
|
RegisterSignal(to_add, COMSIG_MOVABLE_MOVED, PROC_REF(component_move_handler))
|
|
SStgui.update_uis(src)
|
|
|
|
if(shell)
|
|
to_add.register_shell(shell)
|
|
return TRUE
|
|
|
|
/**
|
|
* Adds a component to the circuitboard through a manual action.
|
|
*/
|
|
/obj/item/integrated_circuit/proc/add_component_manually(obj/item/circuit_component/to_add, mob/living/user)
|
|
if (SEND_SIGNAL(src, COMSIG_CIRCUIT_ADD_COMPONENT_MANUALLY, to_add, user) & COMPONENT_CANCEL_ADD_COMPONENT)
|
|
return
|
|
|
|
return add_component(to_add, user)
|
|
|
|
/obj/item/integrated_circuit/proc/component_move_handler(obj/item/circuit_component/source)
|
|
SIGNAL_HANDLER
|
|
if(source.loc != src)
|
|
remove_component(source)
|
|
|
|
/**
|
|
* Removes a component to the circuitboard
|
|
*
|
|
* This removes all connects between the ports
|
|
*/
|
|
/obj/item/integrated_circuit/proc/remove_component(obj/item/circuit_component/to_remove)
|
|
if(shell)
|
|
to_remove.unregister_shell(shell)
|
|
|
|
UnregisterSignal(to_remove, COMSIG_MOVABLE_MOVED)
|
|
current_size -= to_remove.circuit_size
|
|
attached_components -= to_remove
|
|
to_remove.disconnect()
|
|
to_remove.parent = null
|
|
SEND_SIGNAL(to_remove, COMSIG_CIRCUIT_COMPONENT_REMOVED, src)
|
|
SStgui.update_uis(src)
|
|
to_remove.removed_from(src)
|
|
|
|
/obj/item/integrated_circuit/get_cell()
|
|
return cell
|
|
|
|
/obj/item/integrated_circuit/ui_assets(mob/user)
|
|
return list(
|
|
get_asset_datum(/datum/asset/simple/circuit_assets),
|
|
get_asset_datum(/datum/asset/json/circuit_components)
|
|
)
|
|
|
|
/obj/item/integrated_circuit/ui_static_data(mob/user)
|
|
. = list()
|
|
.["global_basic_types"] = GLOB.wiremod_basic_types
|
|
.["screen_x"] = screen_x
|
|
.["screen_y"] = screen_y
|
|
|
|
var/obj/machinery/component_printer/printer = linked_component_printer?.resolve()
|
|
if(!printer)
|
|
return
|
|
.["stored_designs"] = printer.current_unlocked_designs
|
|
|
|
/obj/item/integrated_circuit/ui_data(mob/user)
|
|
. = list()
|
|
.["components"] = list()
|
|
for(var/obj/item/circuit_component/component as anything in attached_components)
|
|
if (component.circuit_flags & CIRCUIT_FLAG_HIDDEN)
|
|
.["components"] += null
|
|
continue
|
|
|
|
var/list/component_data = list()
|
|
component_data["input_ports"] = list()
|
|
for(var/datum/port/input/port as anything in component.input_ports)
|
|
var/current_data = port.value
|
|
if(isatom(current_data)) // Prevent passing the name of the atom.
|
|
current_data = null
|
|
var/list/connected_to = list()
|
|
for(var/datum/port/output/output as anything in port.connected_ports)
|
|
connected_to += REF(output)
|
|
component_data["input_ports"] += list(list(
|
|
"name" = port.name,
|
|
"type" = port.datatype,
|
|
"ref" = REF(port), // The ref is the identifier to work out what it is connected to
|
|
"connected_to" = connected_to,
|
|
"color" = port.color,
|
|
"current_data" = current_data,
|
|
"datatype_data" = port.datatype_ui_data(user)
|
|
))
|
|
component_data["output_ports"] = list()
|
|
for(var/datum/port/output/port as anything in component.output_ports)
|
|
component_data["output_ports"] += list(list(
|
|
"name" = port.name,
|
|
"type" = port.datatype,
|
|
"ref" = REF(port),
|
|
"color" = port.color,
|
|
"datatype_data" = port.datatype_ui_data(user)
|
|
))
|
|
|
|
component_data["name"] = component.display_name
|
|
component_data["x"] = component.rel_x
|
|
component_data["y"] = component.rel_y
|
|
component_data["removable"] = component.removable
|
|
component_data["color"] = component.ui_color
|
|
component_data["category"] = component.category
|
|
component_data["ui_alerts"] = component.ui_alerts
|
|
component_data["ui_buttons"] = component.ui_buttons
|
|
.["components"] += list(component_data)
|
|
|
|
.["variables"] = list()
|
|
for(var/variable_name in circuit_variables)
|
|
var/datum/circuit_variable/variable = circuit_variables[variable_name]
|
|
var/list/variable_data = list()
|
|
variable_data["name"] = variable.name
|
|
variable_data["datatype"] = variable.datatype
|
|
variable_data["color"] = variable.color
|
|
if(islist(variable.value))
|
|
variable_data["is_list"] = TRUE
|
|
.["variables"] += list(variable_data)
|
|
|
|
.["display_name"] = display_name
|
|
|
|
var/obj/item/circuit_component/examined
|
|
if(examined_component)
|
|
examined = examined_component.resolve()
|
|
|
|
.["examined_name"] = examined?.display_name
|
|
.["examined_desc"] = examined?.desc
|
|
.["examined_notices"] = examined?.get_ui_notices()
|
|
.["examined_rel_x"] = examined_rel_x
|
|
.["examined_rel_y"] = examined_rel_y
|
|
.["grid_mode"] = grid_mode
|
|
|
|
.["is_admin"] = (admin_only || isAdminGhostAI(user)) && check_rights_for(user.client, R_VAREDIT)
|
|
|
|
/obj/item/integrated_circuit/ui_host(mob/user)
|
|
if(shell)
|
|
return shell
|
|
return ..()
|
|
|
|
/obj/item/integrated_circuit/can_interact(mob/user)
|
|
if(locked)
|
|
return FALSE
|
|
return ..()
|
|
|
|
/obj/item/integrated_circuit/ui_status(mob/user, datum/ui_state/state)
|
|
. = ..()
|
|
|
|
if (isobserver(user))
|
|
. = max(., UI_UPDATE)
|
|
|
|
// Extra protection because ui_state will not close the UI if they already have the ui open,
|
|
// as ui_state is only set during
|
|
if(admin_only)
|
|
if(!check_rights_for(user.client, R_VAREDIT))
|
|
return UI_CLOSE
|
|
else
|
|
return UI_INTERACTIVE
|
|
|
|
/obj/item/integrated_circuit/ui_state(mob/user)
|
|
if(!shell)
|
|
return GLOB.hands_state
|
|
return GLOB.physical_obscured_state
|
|
|
|
/obj/item/integrated_circuit/ui_interact(mob/user, datum/tgui/ui)
|
|
ui = SStgui.try_update_ui(user, src, ui)
|
|
if(!ui)
|
|
ui = new(user, src, "IntegratedCircuit", name)
|
|
ui.open()
|
|
ui.set_autoupdate(FALSE)
|
|
|
|
#define WITHIN_RANGE(id, table) (id >= 1 && id <= length(table))
|
|
|
|
/obj/item/integrated_circuit/ui_act(action, list/params, datum/tgui/ui)
|
|
. = ..()
|
|
if(.)
|
|
return
|
|
|
|
switch(action)
|
|
if("add_connection")
|
|
var/input_component_id = text2num(params["input_component_id"])
|
|
var/output_component_id = text2num(params["output_component_id"])
|
|
var/input_port_id = text2num(params["input_port_id"])
|
|
var/output_port_id = text2num(params["output_port_id"])
|
|
if(!WITHIN_RANGE(input_component_id, attached_components) || !WITHIN_RANGE(output_component_id, attached_components))
|
|
return
|
|
var/obj/item/circuit_component/input_component = attached_components[input_component_id]
|
|
var/obj/item/circuit_component/output_component = attached_components[output_component_id]
|
|
|
|
if(!WITHIN_RANGE(input_port_id, input_component.input_ports) || !WITHIN_RANGE(output_port_id, output_component.output_ports))
|
|
return
|
|
var/datum/port/input/input_port = input_component.input_ports[input_port_id]
|
|
var/datum/port/output/output_port = output_component.output_ports[output_port_id]
|
|
|
|
if(!input_port.can_receive_from_datatype(output_port.datatype))
|
|
return
|
|
input_port.connect(output_port)
|
|
. = TRUE
|
|
if("remove_connection")
|
|
var/component_id = text2num(params["component_id"])
|
|
var/is_input = params["is_input"]
|
|
var/port_id = text2num(params["port_id"])
|
|
|
|
if(!WITHIN_RANGE(component_id, attached_components))
|
|
return
|
|
var/obj/item/circuit_component/component = attached_components[component_id]
|
|
|
|
var/list/port_table
|
|
if(is_input)
|
|
port_table = component.input_ports
|
|
else
|
|
port_table = component.output_ports
|
|
|
|
if(!WITHIN_RANGE(port_id, port_table))
|
|
return
|
|
|
|
var/datum/port/port = port_table[port_id]
|
|
port.disconnect_all()
|
|
. = TRUE
|
|
if("detach_component")
|
|
var/component_id = text2num(params["component_id"])
|
|
if(!WITHIN_RANGE(component_id, attached_components))
|
|
return
|
|
var/obj/item/circuit_component/component = attached_components[component_id]
|
|
if(!component.removable)
|
|
return
|
|
component.disconnect()
|
|
remove_component(component)
|
|
|
|
var/mob/user = ui.user
|
|
if(component.loc == src)
|
|
user.put_in_hands(component)
|
|
var/obj/machinery/component_printer/printer = linked_component_printer?.resolve()
|
|
if (!isnull(printer))
|
|
printer.base_item_interaction(user, component)
|
|
. = TRUE
|
|
if("set_component_coordinates")
|
|
var/component_id = text2num(params["component_id"])
|
|
if(!WITHIN_RANGE(component_id, attached_components))
|
|
return
|
|
var/obj/item/circuit_component/component = attached_components[component_id]
|
|
component.rel_x = min(max(-COMPONENT_MAX_POS, text2num(params["rel_x"])), COMPONENT_MAX_POS)
|
|
component.rel_y = min(max(-COMPONENT_MAX_POS, text2num(params["rel_y"])), COMPONENT_MAX_POS)
|
|
. = TRUE
|
|
if("set_component_input")
|
|
var/component_id = text2num(params["component_id"])
|
|
var/port_id = text2num(params["port_id"])
|
|
if(!WITHIN_RANGE(component_id, attached_components))
|
|
return
|
|
var/obj/item/circuit_component/component = attached_components[component_id]
|
|
if(!WITHIN_RANGE(port_id, component.input_ports))
|
|
return
|
|
var/datum/port/input/port = component.input_ports[port_id]
|
|
|
|
if(params["set_null"])
|
|
port.set_input(null)
|
|
return TRUE
|
|
|
|
if(params["marked_atom"])
|
|
if(!(port.datatype_handler.datatype_flags & DATATYPE_FLAG_ALLOW_ATOM_INPUT))
|
|
return
|
|
var/obj/item/multitool/circuit/marker = usr.get_active_held_item()
|
|
// Let's admins upload marked datums to an entity port.
|
|
if(!istype(marker))
|
|
var/client/user = usr.client
|
|
if(!check_rights_for(user, R_VAREDIT))
|
|
return TRUE
|
|
var/atom/marked_atom = user.holder.marked_datum
|
|
if(!marked_atom)
|
|
return TRUE
|
|
port.set_input(marked_atom)
|
|
balloon_alert(usr, "updated [port.name]'s value to marked object.")
|
|
return TRUE
|
|
if(!marker.marked_atom)
|
|
port.set_input(null)
|
|
marker.say("Cleared port ('[port.name]')'s value.")
|
|
return TRUE
|
|
marker.say("Updated port ('[port.name]')'s value to the marked entity.")
|
|
port.set_input(marker.marked_atom)
|
|
return TRUE
|
|
|
|
var/user_input = port.handle_manual_input(usr, params["input"])
|
|
if(isnull(user_input))
|
|
return TRUE
|
|
port.set_input(user_input)
|
|
. = TRUE
|
|
if("get_component_value")
|
|
var/component_id = text2num(params["component_id"])
|
|
var/port_id = text2num(params["port_id"])
|
|
if(!WITHIN_RANGE(component_id, attached_components))
|
|
return
|
|
var/obj/item/circuit_component/component = attached_components[component_id]
|
|
if(!WITHIN_RANGE(port_id, component.output_ports))
|
|
return
|
|
|
|
var/datum/port/output/port = component.output_ports[port_id]
|
|
var/value = port.value
|
|
if(isatom(value))
|
|
value = PORT_TYPE_ATOM
|
|
else if(isnull(value))
|
|
value = "null"
|
|
var/string_form = copytext("[value]", 1, PORT_MAX_STRING_DISPLAY)
|
|
if(length(string_form) >= PORT_MAX_STRING_DISPLAY-1)
|
|
string_form += "..."
|
|
balloon_alert(usr, "[port.name] value: [string_form]")
|
|
. = TRUE
|
|
if("set_display_name")
|
|
var/new_name = params["display_name"]
|
|
|
|
if(new_name)
|
|
set_display_name(params["display_name"])
|
|
else
|
|
set_display_name("")
|
|
. = TRUE
|
|
if("toggle_grid_mode")
|
|
toggle_grid_mode()
|
|
. = TRUE
|
|
if("set_examined_component")
|
|
var/component_id = text2num(params["component_id"])
|
|
if(!WITHIN_RANGE(component_id, attached_components))
|
|
return
|
|
examined_component = WEAKREF(attached_components[component_id])
|
|
examined_rel_x = text2num(params["x"])
|
|
examined_rel_y = text2num(params["y"])
|
|
. = TRUE
|
|
if("remove_examined_component")
|
|
examined_component = null
|
|
. = TRUE
|
|
if("save_circuit")
|
|
return attempt_save_to(usr.client)
|
|
if("add_variable")
|
|
var/variable_identifier = trim(copytext(params["variable_name"], 1, PORT_MAX_NAME_LENGTH))
|
|
if(variable_identifier in circuit_variables)
|
|
return TRUE
|
|
if(variable_identifier == "")
|
|
return TRUE
|
|
var/variable_datatype = params["variable_datatype"]
|
|
if(!(variable_datatype in GLOB.wiremod_basic_types))
|
|
return
|
|
if(params["is_list"])
|
|
variable_datatype = PORT_TYPE_LIST(variable_datatype)
|
|
else if(params["is_assoc_list"])
|
|
variable_datatype = PORT_TYPE_ASSOC_LIST(PORT_TYPE_STRING, variable_datatype)
|
|
var/datum/circuit_variable/variable = new /datum/circuit_variable(variable_identifier, variable_datatype)
|
|
if(params["is_assoc_list"])
|
|
variable.set_value(list())
|
|
assoc_list_variables[variable_identifier] = variable
|
|
else if(params["is_list"])
|
|
variable.set_value(list())
|
|
list_variables[variable_identifier] = variable
|
|
else
|
|
modifiable_circuit_variables[variable_identifier] = variable
|
|
circuit_variables[variable_identifier] = variable
|
|
. = TRUE
|
|
if("remove_variable")
|
|
var/variable_identifier = params["variable_name"]
|
|
if(!(variable_identifier in circuit_variables))
|
|
return
|
|
var/datum/circuit_variable/variable = circuit_variables[variable_identifier]
|
|
if(!variable)
|
|
return
|
|
circuit_variables -= variable_identifier
|
|
list_variables -= variable_identifier
|
|
modifiable_circuit_variables -= variable_identifier
|
|
qdel(variable)
|
|
. = TRUE
|
|
if("add_setter_or_getter")
|
|
if(setter_and_getter_count >= max_setters_and_getters)
|
|
balloon_alert(usr, "setter and getter count at maximum capacity")
|
|
return
|
|
var/designated_type = /obj/item/circuit_component/variable/getter
|
|
if(params["is_setter"])
|
|
designated_type = /obj/item/circuit_component/variable/setter
|
|
var/obj/item/circuit_component/variable/component = new designated_type(src)
|
|
if(!add_component(component, usr))
|
|
qdel(component)
|
|
return
|
|
component.variable_name.set_input(params["variable"])
|
|
component.rel_x = text2num(params["rel_x"])
|
|
component.rel_y = text2num(params["rel_y"])
|
|
RegisterSignal(component, COMSIG_CIRCUIT_COMPONENT_REMOVED, PROC_REF(clear_setter_or_getter))
|
|
setter_and_getter_count++
|
|
return TRUE
|
|
if("move_screen")
|
|
screen_x = text2num(params["screen_x"])
|
|
screen_y = text2num(params["screen_y"])
|
|
if("perform_action")
|
|
var/component_id = text2num(params["component_id"])
|
|
if(!WITHIN_RANGE(component_id, attached_components))
|
|
return
|
|
var/obj/item/circuit_component/component = attached_components[component_id]
|
|
SEND_SIGNAL(component, COMSIG_CIRCUIT_COMPONENT_PERFORM_ACTION, ui.user, params["action_name"])
|
|
component.ui_perform_action(ui.user, params["action_name"])
|
|
if("print_component")
|
|
var/component_path = text2path(params["component_to_print"])
|
|
var/obj/item/circuit_component/component
|
|
if((!admin_only && !isAdminGhostAI(ui.user)) || !check_rights_for(ui.user.client, R_SPAWN))
|
|
var/obj/machinery/component_printer/printer = linked_component_printer?.resolve()
|
|
if(!printer)
|
|
balloon_alert(ui.user, "linked printer not found!")
|
|
return
|
|
component = printer.print_component(component_path, user_data = ID_DATA(usr))
|
|
if(!component)
|
|
balloon_alert(ui.user, "failed to make the component!")
|
|
return
|
|
else
|
|
if(!ispath(component_path, /obj/item/circuit_component))
|
|
return
|
|
component = new component_path(drop_location())
|
|
component.datum_flags |= DF_VAR_EDITED
|
|
if(!add_component(component))
|
|
return
|
|
component.rel_x = text2num(params["rel_x"])
|
|
component.rel_y = text2num(params["rel_y"])
|
|
return TRUE
|
|
|
|
#undef WITHIN_RANGE
|
|
|
|
/obj/item/integrated_circuit/balloon_alert(mob/viewer, text)
|
|
if(shell)
|
|
return shell.balloon_alert(viewer, text)
|
|
return ..()
|
|
|
|
/obj/item/integrated_circuit/proc/clear_setter_or_getter(datum/source)
|
|
SIGNAL_HANDLER
|
|
// This'll also be called in the Destroy() override of /obj/item/circuit_component
|
|
if(!QDELING(source))
|
|
qdel(source)
|
|
setter_and_getter_count--
|
|
|
|
/obj/item/integrated_circuit/proc/on_atom_usb_cable_try_attach(datum/source, obj/item/usb_cable/usb_cable, mob/user)
|
|
SIGNAL_HANDLER
|
|
usb_cable.balloon_alert(user, "circuit needs to be in a compatible shell")
|
|
return COMSIG_CANCEL_USB_CABLE_ATTACK
|
|
|
|
/// Sets the display name that appears on the shell.
|
|
/obj/item/integrated_circuit/proc/set_display_name(new_name)
|
|
display_name = copytext_char(new_name, 1, label_max_length)
|
|
if(!shell)
|
|
return
|
|
|
|
if(display_name != "")
|
|
if(!admin_only)
|
|
shell.name = "[initial(shell.name)] ([strip_html(display_name)])"
|
|
else
|
|
shell.name = display_name
|
|
else
|
|
shell.name = initial(shell.name)
|
|
|
|
/// Toggles the grid mode property for this circuit.
|
|
/obj/item/integrated_circuit/proc/toggle_grid_mode()
|
|
grid_mode = !grid_mode
|
|
|
|
/**
|
|
* Returns the creator of the integrated circuit. Used in admin messages and other related things.
|
|
*/
|
|
/obj/item/integrated_circuit/proc/get_creator_admin()
|
|
return get_creator(include_link = TRUE)
|
|
|
|
/**
|
|
* Returns the creator of the integrated circuit. Used in admin logs and other related things.
|
|
*/
|
|
/obj/item/integrated_circuit/proc/get_creator(include_link = FALSE)
|
|
var/datum/mind/inserter
|
|
if(inserter_mind)
|
|
inserter = inserter_mind.resolve()
|
|
|
|
var/obj/item/card/id/id_card
|
|
if(owner_id)
|
|
id_card = owner_id.resolve()
|
|
|
|
return "[src] (Shell: [shell || "*null*"], Inserter: [key_name(inserter, include_link)], Owner ID: [id_card?.name || "*null*"])"
|
|
|
|
/// Attempts to save a circuit to a given client
|
|
/obj/item/integrated_circuit/proc/attempt_save_to(client/saver)
|
|
if(!check_rights_for(saver, R_VAREDIT))
|
|
return FALSE
|
|
var/temp_file = file("data/CircuitDownloadTempFile")
|
|
fdel(temp_file)
|
|
WRITE_FILE(temp_file, convert_to_json())
|
|
DIRECT_OUTPUT(saver, ftp(temp_file, "[display_name || "circuit"].json"))
|
|
return TRUE
|
|
|
|
/obj/item/integrated_circuit/admin
|
|
name = "administrative circuit"
|
|
desc = "The components installed in here are far beyond your comprehension."
|
|
|
|
admin_only = TRUE
|