Files
Bubberstation/code/modules/research/machinery/departmental_circuit_imprinter.dm
SkyratBot 6a5f3c50c4 [MIRROR] Material container & related stuff ui refactors & clean-up [MDB IGNORE] (#22667)
* Material container & related stuff ui refactors & clean-up (#76220)

## About The Pull Request

**1. Material container clean-up & refactor**
- Replaced `total_amount` var with `total_amount()` proc, this var can
be easily computed by summing up all material amounts rather than
storing it as a var which is tedious to update & keep track of when
materials are added/removed
- Removed unused procs `transer_amt_to()`, `can_insert_amount_mat()`,
and `get_categories()`. These procs are not used anywhere in the
codebase so let's remove them & make some space.
- Callbacks are replaced with signals, the callbacks don't need to be
explicitly garbage collected & having macros & procs marked with
`SIGNAL_HANDLER` makes your intentions more readable & explicit.
- Fixes #76151
All material adding, removal, checking operations are "Integer"
operations, i.e. the final value is rounded & them made 1 if the final
value is 0 using the macro `OPTIMIZE_COST`[coudn't come up with a better
name]. No more dealing with decimal value materials
The problem was after the protolathe was upgraded with better parts all
the design costs were multiplied with a decimal `efficiency_coeff`
value, this means even though in the UI the cost was displayed as 60
bluespace crystals its actual cost was `60.0001` something in the
backend causing this check for materials to fail & print the error
message.
- Replaced `GetComponent(/datum/component_material_container)` with just
a simple ref to the material container when adding the component, so we
can save some overhead from calling this proc
- Gave all procs a ton of documentation with documentation having
documentation
- Fixes #76506 RCD and other devices that uses the silo link upgrade now
have the correct material usages
- Fixes #72096. It wasn't just a problem with ancient protolathe but
with all machines that used `datum/component/remote_materials` the
problem was remote materials would add an instance of
`datum/remote/material_container` if it wanted to use local storage but
this component would get added before `datum/component/remote_materials`
could be registered i.e. it comes before remote_materials in the
component list. So when the machine is destroyed it will first destroy
`material_container` & then `remote_materials` therefore destroying the
materials before they could get ejected
- Silo link is established when parent is registered with remote
materials raher than adding an external timer which is faster
- Everything that uses a material container will auto eject their sheets
when destroyed
- Moved this & remote materials into its own folder for better
organization

**2. Material UI Changes**
- Removed the x25 & x50 print buttons from the autolathe, now they just
have x5 & x10 buttons like the protolathe, These buttons were of no use
since you could just type the exact amount you want to print in the
`[Max: <some amount>]` side bar. The code to compute these buttons was
just plain right nasty & some of it unused in the UI.
- The material eject button in the material bar does not gray out when
you can eject exactly one sheet
- All material cost are integer values rounded
- Fixes #76253 Exosuit Fabricator sends the material container static
data to the UI so its material bar is not greyed out when there are
sufficient materials to eject
- Component printer material bar sends the material container static
data to the UI so its material bar is not greyed out when there are
sufficient materials to eject
- Autolathe Material bars now display number of sheets available
- Max printable amount of items are now computed & updated correctly in
the UI. They were displaying wrong values & now get updated when items
are printed, materials are removed
- Silo hold actually works now. When a machine is put on hold it calls
this proc

e929cf39cd/code/datums/components/remote_materials.dm (L78-L87)
Notice how the key is `src` so we should be consistent during checking
if a machine is on hold using the same `src` var. But for some reason we
did dumb shit like this

e929cf39cd/code/datums/components/remote_materials.dm (L150-L153)
What is category? Why do we care for the area the machine is in? None of
it made sense so i removed all that junk and just made it check for
`src` like it should
- Removed redundant `removable` & `sheets` var from the material
container ui_data. These vars are unused in the UI
- If an item does not have the required materials then upon clicking
that item you will not get any error message but instead nothing happens

## Changelog
🆑
fix: items can be printed from autolathe & protolathe when the exact
material amounts are present in them after upgrading
fix: max printable amount now shows the correct value & updates when
items are printed, materials are removed in the autolathe & protolathe
fix: component printer material bar is not greyed out when there are
sufficient materials to eject
fix: rcd and other devices that uses the silo link upgrade now have the
correct material usages
fix: silo hold actually works
fix: machines using local storage to hold materials will eject it's
materials as sheets when deconstructed/destroyed
refactor: Autolathe Material bars now display number of sheets available
refactor: printing an item that does not have enough materials will fail
silently with no error messages
refactor: Drone dispenser will eject sheets upon deconstruction
refactor: all things that store materials will auto ejects its sheets(if
there is sufficient material) when destroyed
refactor: inserting an item into the material container will display the
units consumed as sheets not absolute units
refactor: removed x25 & x50 print buttons from the autolathe

* Material container & related stuff ui refactors & clean-up

* Update ammo_workbench.dm

---------

Co-authored-by: SyncIt21 <110812394+SyncIt21@users.noreply.github.com>
Co-authored-by: Giz <13398309+vinylspiders@users.noreply.github.com>
2023-07-25 02:53:43 -04:00

12 lines
698 B
Plaintext

/obj/machinery/rnd/production/circuit_imprinter/department
name = "department circuit imprinter"
desc = "A special circuit imprinter with a built in interface meant for departmental usage, with built in ExoSync receivers allowing it to print designs researched that match its ROM-encoded department type."
icon_state = "circuit_imprinter"
circuit = /obj/item/circuitboard/machine/circuit_imprinter/department
/obj/machinery/rnd/production/circuit_imprinter/department/science
name = "department circuit imprinter (Science)"
circuit = /obj/item/circuitboard/machine/circuit_imprinter/department/science
allowed_department_flags = DEPARTMENT_BITFLAG_SCIENCE
payment_department = ACCOUNT_SCI