Files
Bubberstation/code/controllers/subsystem/nightshift.dm
lessthanthree 312cd8880d Station announcements cleanup (#79315)
## About The Pull Request

- As the size of the announcement proc has grown over the past few PRs,
did a pass over them for readability and consistency
- Include the arg names for coders unfamiliar with the new announcement
format
- Replaced leftover hardcoded Central Command text with the command name
proc, so all announcements reflect the command name if changed by an
admin
- Replaced hard coded emergency shuttle timer text with the actual
timeleft vars, so it's correct if the timers are changed for any reason
- Darkens the dark mode blue/red headers to be more red less pink, while
staying in accessibility standards
- Adds a lower profile grey colour for automated non-Central Command
announcements

## Changelog

🆑 LT3
code: Emergency shuttle announcements no longer use hardcoded values
code: Central Command announcements now correctly use its new name when
changed
spellcheck: Consistency pass on event announcements
/🆑
2023-11-04 18:38:52 -06:00

67 lines
2.4 KiB
Plaintext

SUBSYSTEM_DEF(nightshift)
name = "Night Shift"
wait = 10 MINUTES
var/nightshift_active = FALSE
var/nightshift_start_time = 702000 //7:30 PM, station time
var/nightshift_end_time = 270000 //7:30 AM, station time
var/nightshift_first_check = 30 SECONDS
var/high_security_mode = FALSE
var/list/currentrun
/datum/controller/subsystem/nightshift/Initialize()
if(!CONFIG_GET(flag/enable_night_shifts))
can_fire = FALSE
return SS_INIT_SUCCESS
/datum/controller/subsystem/nightshift/fire(resumed = FALSE)
if(resumed)
update_nightshift(resumed = TRUE)
return
if(world.time - SSticker.round_start_time < nightshift_first_check)
return
check_nightshift()
/datum/controller/subsystem/nightshift/proc/announce(message)
priority_announce(
text = message,
sound = 'sound/misc/notice2.ogg',
sender_override = "Automated Lighting System Announcement",
color_override = "grey",
)
/datum/controller/subsystem/nightshift/proc/check_nightshift()
var/emergency = SSsecurity_level.get_current_level_as_number() >= SEC_LEVEL_RED
var/announcing = TRUE
var/time = station_time()
var/night_time = (time < nightshift_end_time) || (time > nightshift_start_time)
if(high_security_mode != emergency)
high_security_mode = emergency
if(night_time)
announcing = FALSE
if(!emergency)
announce("Restoring night lighting configuration to normal operation.")
else
announce("Disabling night lighting: Station is in a state of emergency.")
if(emergency)
night_time = FALSE
if(nightshift_active != night_time)
update_nightshift(night_time, announcing)
/datum/controller/subsystem/nightshift/proc/update_nightshift(active, announce = TRUE, resumed = FALSE, forced = FALSE)
if(!resumed)
currentrun = SSmachines.get_machines_by_type_and_subtypes(/obj/machinery/power/apc)
nightshift_active = active
if(announce)
if (active)
announce("Good evening, crew. To reduce power consumption and stimulate the circadian rhythms of some species, all of the lights aboard the station have been dimmed for the night.")
else
announce("Good morning, crew. As it is now day time, all of the lights aboard the station have been restored to their former brightness.")
for(var/obj/machinery/power/apc/APC as anything in currentrun)
currentrun -= APC
if (APC.area && (APC.area.type in GLOB.the_station_areas))
APC.set_nightshift(nightshift_active)
if(MC_TICK_CHECK && !forced) // subsystem will be in state SS_IDLE if forced by an admin
return