Pickle-Coding c1f11f26ce Converts arbitrary energy units to the joule. Fixes conservation of energy issues relating to charging cells. (#81579)
## About The Pull Request
Removes all arbitrary energy and power units in the codebase. Everything
is replaced with the joule and watt, with 1 = 1 joule, or 1 watt if you
are going to multiply by time. This is a visible change, where all
arbitrary energy units you see in the game will get proper prefixed
units of energy.

With power cells being converted to the joule, charging one joule of a
power cell will require one joule of energy.

The grid will now store energy, instead of power. When an energy usage
is described as using the watt, a power to energy conversion based on
the relevant subsystem's timing (usually multiplying by seconds_per_tick
or applying power_to_energy()) is needed before adding or removing from
the grid. Power usages that are described as the watt is really anything
you would scale by time before applying the load. If it's described as a
joule, no time conversion is needed. Players will still read the grid as
power, having no visible change.

Machines that dynamically use power with the use_power() proc will
directly drain from the grid (and apc cell if there isn't enough)
instead of just tallying it up on the dynamic power usages for the area.
This should be more robust at conserving energy as the surplus is
updated on the go, preventing charging cells from nothing.

APCs no longer consume power for the dynamic power usage channels. APCs
will consume power for static power usages. Because static power usages
are added up without checking surplus, static power consumption will be
applied before any machine processes. This will give a more truthful
surplus for dynamic power consumers.

APCs will display how much power it is using for charging the cell. APC
cell charging applies power in its own channel, which gets added up to
the total. This will prevent invisible power usage you see when looking
at the power monitoring console.

After testing in MetaStation, I found roundstart power consumption to be
around 406kW after all APCs get fully charged. During the roundstart APC
charge rush, the power consumption can get as high as over 2MW (up to
25kW per roundstart APC charging) as long as there's that much
available.

Because of the absurd potential power consumption of charging APCs near
roundstart, I have changed how APCs decide to charge. APCs will now
charge only after all other machines have processed in the machines
processing subsystem. This will make sure APC charging won't disrupt
machines taking from the grid, and should stop APCs getting their power
drained due to others demanding too much power while charging. I have
removed the delays for APC charging too, so they start charging
immediately whenever there's excess power. It also stops them turning
red when a small amount of cell gets drained (airlocks opening and shit
during APC charge rush), as they immediately become fully charged
(unless too much energy got drained somehow) before changing icon.

Engineering SMES now start at 100% charge instead of 75%. I noticed
cells were draining earlier than usual after these changes, so I am
making them start maxed to try and combat that.

These changes will fix all conservation of energy issues relating to
charging powercells.
## Why It's Good For The Game
Closes #73438
Closes #75789
Closes #80634
Closes #82031

Makes it much easier to interface with the power system in the codebase.
It's more intuitive. Removes a bunch of conservation of energy issues,
making energy and power much more meaningful. It will help the
simulation remain immersive as players won't encounter energy
duplication so easily. Arbitrary energy units getting replaced with the
joule will also tell people more meaningful information when reading it.
APC charging will feel more snappy.
## Changelog
🆑
fix: Fixes conservation of energy issues relating to charging
powercells.
qol: APCs will display how much power they are using to charge their
cell. This is accounted for in the power monitoring console.
qol: All arbitrary power cell energy units you see are replaced with
prefixed joules.
balance: As a consequence of the conservation of energy issues getting
fixed, the power consumption for charging cells is now very significant.
balance: APCs only use surplus power from the grid after every machine
processes when charging, preventing APCs from causing others to
discharge while charging.
balance: Engineering SMES start at max charge to combat the increased
energy loss due to conservation of energy fixes.
/🆑

---------

Co-authored-by: SyncIt21 <110812394+SyncIt21@users.noreply.github.com>
Co-authored-by: Ghom <42542238+Ghommie@users.noreply.github.com>
2024-03-23 16:58:56 +01:00

93 lines
2.9 KiB
Plaintext

////////////////////////////////////////////
// POWERNET DATUM
// each contiguous network of cables & nodes
/////////////////////////////////////
/datum/powernet
var/number // unique id
var/list/cables = list() // all cables & junctions
var/list/nodes = list() // all connected machines
var/load = 0 // the current load on the powernet, increased by each machine at processing
var/newavail = 0 // what available power was gathered last tick, then becomes...
var/avail = 0 //...the current available power in the powernet
var/netexcess = 0 // excess power on the powernet (typically avail-load)///////
var/delayedload = 0 // load applied to powernet between power ticks.
/datum/powernet/New()
SSmachines.powernets += src
/datum/powernet/Destroy()
//Go away references, you suck!
for(var/obj/structure/cable/C in cables)
cables -= C
C.powernet = null
for(var/obj/machinery/power/M in nodes)
nodes -= M
M.powernet = null
SSmachines.powernets -= src
return ..()
/datum/powernet/proc/is_empty()
return !cables.len && !nodes.len
//remove a cable from the current powernet
//if the powernet is then empty, delete it
//Warning : this proc DON'T check if the cable exists
/datum/powernet/proc/remove_cable(obj/structure/cable/C)
cables -= C
C.powernet = null
if(is_empty())//the powernet is now empty...
qdel(src)///... delete it
//add a cable to the current powernet
//Warning : this proc DON'T check if the cable exists
/datum/powernet/proc/add_cable(obj/structure/cable/C)
if(C.powernet)// if C already has a powernet...
if(C.powernet == src)
return
else
C.powernet.remove_cable(C) //..remove it
C.powernet = src
cables +=C
//remove a power machine from the current powernet
//if the powernet is then empty, delete it
//Warning : this proc DON'T check if the machine exists
/datum/powernet/proc/remove_machine(obj/machinery/power/M)
nodes -=M
M.powernet = null
if(is_empty())//the powernet is now empty...
qdel(src)///... delete it
//add a power machine to the current powernet
//Warning : this proc DON'T check if the machine exists
/datum/powernet/proc/add_machine(obj/machinery/power/M)
if(M.powernet)// if M already has a powernet...
if(M.powernet == src)
return
else
M.disconnect_from_network()//..remove it
M.powernet = src
nodes[M] = M
//handles the power changes in the powernet
//called every ticks by the powernet controller
/datum/powernet/proc/reset()
//see if there's a surplus of power remaining in the powernet and stores unused power in the SMES
netexcess = avail - load
if(netexcess > 100 && length(nodes)) // if there was excess power last cycle
for(var/obj/machinery/power/smes/S in nodes) // find the SMESes in the network
S.restore() // and restore some of the power that was used
// reset the powernet
load = delayedload
delayedload = 0
avail = newavail
newavail = 0
/datum/powernet/proc/get_electrocute_damage()
return ELECTROCUTE_DAMAGE(energy_to_power(avail)) // Assuming 1 second of contact.