mirror of
https://github.com/Bubberstation/Bubberstation.git
synced 2026-01-16 03:56:20 +00:00
Don't store hard refs to an area which can cause race condtions Instead, get our area only when we need it The following runtime has occured 4426 time(s). runtime error: Cannot read null.atmosalm proc name: update icon (/obj/machinery/airalarm/update_icon) source file: airalarm.dm,535 usr: null src: the alarm (/obj/machinery/airalarm)
73 lines
2.0 KiB
Plaintext
73 lines
2.0 KiB
Plaintext
/datum/wires/airalarm
|
|
holder_type = /obj/machinery/airalarm
|
|
|
|
/datum/wires/airalarm/New(atom/holder)
|
|
wires = list(
|
|
WIRE_POWER,
|
|
WIRE_IDSCAN, WIRE_AI,
|
|
WIRE_PANIC, WIRE_ALARM
|
|
)
|
|
add_duds(3)
|
|
..()
|
|
|
|
/datum/wires/airalarm/interactable(mob/user)
|
|
var/obj/machinery/airalarm/A = holder
|
|
if(A.panel_open && A.buildstage == 2)
|
|
return TRUE
|
|
|
|
/datum/wires/airalarm/get_status()
|
|
var/obj/machinery/airalarm/A = holder
|
|
var/list/status = list()
|
|
status += "The interface light is [A.locked ? "red" : "green"]."
|
|
status += "The short indicator is [A.shorted ? "lit" : "off"]."
|
|
status += "The AI connection light is [!A.aidisabled ? "on" : "off"]."
|
|
return status
|
|
|
|
/datum/wires/airalarm/on_pulse(wire)
|
|
var/obj/machinery/airalarm/A = holder
|
|
switch(wire)
|
|
if(WIRE_POWER) // Short out for a long time.
|
|
if(!A.shorted)
|
|
A.shorted = TRUE
|
|
A.update_icon()
|
|
addtimer(A, "reset", 1200, FALSE, wire)
|
|
if(WIRE_IDSCAN) // Toggle lock.
|
|
A.locked = !A.locked
|
|
if(WIRE_AI) // Disable AI control for a while.
|
|
if(!A.aidisabled)
|
|
A.aidisabled = TRUE
|
|
addtimer(A, "reset", 100, FALSE, wire)
|
|
if(WIRE_PANIC) // Toggle panic siphon.
|
|
if(!A.shorted)
|
|
if(A.mode == 1) // AALARM_MODE_SCRUB
|
|
A.mode = 3 // AALARM_MODE_PANIC
|
|
else
|
|
A.mode = 1 // AALARM_MODE_SCRUB
|
|
A.apply_mode()
|
|
if(WIRE_ALARM) // Clear alarms.
|
|
var/area/AA = get_area_master(A)
|
|
if(AA.atmosalert(0, holder))
|
|
A.post_alert(0)
|
|
A.update_icon()
|
|
|
|
/datum/wires/airalarm/on_cut(wire, mend)
|
|
var/obj/machinery/airalarm/A = holder
|
|
switch(wire)
|
|
if(WIRE_POWER) // Short out forever.
|
|
A.shock(usr, 50)
|
|
A.shorted = !mend
|
|
A.update_icon()
|
|
if(WIRE_IDSCAN)
|
|
if(!mend)
|
|
A.locked = TRUE
|
|
if(WIRE_AI)
|
|
A.aidisabled = mend // Enable/disable AI control.
|
|
if(WIRE_PANIC) // Force panic syphon on.
|
|
if(!mend && !A.shorted)
|
|
A.mode = 3 // AALARM_MODE_PANIC
|
|
A.apply_mode()
|
|
if(WIRE_ALARM) // Post alarm.
|
|
var/area/AA = get_area_master(A)
|
|
if(AA.atmosalert(2, holder))
|
|
A.post_alert(2)
|
|
A.update_icon() |