Acts like a normal vent, but has an input AND output.
|
|
*/
|
|
#define EXT_BOUND 1
|
|
#define INPUT_MIN 2
|
|
#define OUTPUT_MAX 4
|
|
|
|
/obj/machinery/atmospherics/components/binary/dp_vent_pump
|
|
icon = 'icons/obj/atmospherics/components/unary_devices.dmi' //We reuse the normal vent icons!
|
|
icon_state = "dpvent_map"
|
|
|
|
//node2 is output port
|
|
//node1 is input port
|
|
|
|
name = "dual-port air vent"
|
|
desc = "Has a valve and pump attached to it. There are two ports."
|
|
|
|
level = 1
|
|
var/frequency = 0
|
|
var/id = null
|
|
var/datum/radio_frequency/radio_connection
|
|
|
|
var/on = 0
|
|
var/pump_direction = 1 //0 = siphoning, 1 = releasing
|
|
|
|
var/external_pressure_bound = ONE_ATMOSPHERE
|
|
var/input_pressure_min = 0
|
|
var/output_pressure_max = 0
|
|
|
|
var/pressure_checks = EXT_BOUND
|
|
//EXT_BOUND: Do not pass external_pressure_bound
|
|
//INPUT_MIN: Do not pass input_pressure_min
|
|
//OUTPUT_MAX: Do not pass output_pressure_max
|
|
|
|
/obj/machinery/atmospherics/components/binary/dp_vent_pump/Destroy()
|
|
if(radio_controller)
|
|
radio_controller.remove_object(src, frequency)
|
|
return ..()
|
|
|
|
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume
|
|
name = "large dual-port air vent"
|
|
|
|
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/New()
|
|
..()
|
|
var/datum/gas_mixture/air1 = AIR1
|
|
var/datum/gas_mixture/air2 = AIR2
|
|
air1.volume = 1000
|
|
air2.volume = 1000
|
|
|
|
/obj/machinery/atmospherics/components/binary/dp_vent_pump/update_icon_nopipes()
|
|
overlays.Cut()
|
|
if(showpipe)
|
|
overlays += getpipeimage('icons/obj/atmospherics/components/unary_devices.dmi', "dpvent_cap")
|
|
|
|
if(!on || stat & (NOPOWER|BROKEN))
|
|
icon_state = "vent_off"
|
|
return
|
|
|
|
if(pump_direction)
|
|
icon_state = "vent_out"
|
|
else
|
|
icon_state = "vent_in"
|
|
|
|
/obj/machinery/atmospherics/components/binary/dp_vent_pump/process_atmos()
|
|
..()
|
|
|
|
if(!on)
|
|
return 0
|
|
var/datum/gas_mixture/air1 = AIR1
|
|
var/datum/gas_mixture/air2 = AIR2
|
|
|
|
var/datum/gas_mixture/environment = loc.return_air()
|
|
var/environment_pressure = environment.return_pressure()
|
|
|
|
if(pump_direction) //input -> external
|
|
var/pressure_delta = 10000
|
|
|
|
if(pressure_checks&EXT_BOUND)
|
|
pressure_delta = min(pressure_delta, (external_pressure_bound - environment_pressure))
|
|
if(pressure_checks&INPUT_MIN)
|
|
pressure_delta = min(pressure_delta, (air1.return_pressure() - input_pressure_min))
|
|
|
|
if(pressure_delta > 0)
|
|
if(air1.temperature > 0)
|
|
var/transfer_moles = pressure_delta*environment.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
|
|
|
|
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
|
|
|
|
loc.assume_air(removed)
|
|
air_update_turf()
|
|
|
|
var/datum/pipeline/parent1 = PARENT1
|
|
parent1.update = 1
|
|
|
|
else //external -> output
|
|
var/pressure_delta = 10000
|
|
|
|
if(pressure_checks&EXT_BOUND)
|
|
pressure_delta = min(pressure_delta, (environment_pressure - external_pressure_bound))
|
|
if(pressure_checks&INPUT_MIN)
|
|
pressure_delta = min(pressure_delta, (output_pressure_max - air2.return_pressure()))
|
|
|
|
if(pressure_delta > 0)
|
|
if(environment.temperature > 0)
|
|
var/transfer_moles = pressure_delta*air2.volume/(environment.temperature * R_IDEAL_GAS_EQUATION)
|
|
|
|
var/datum/gas_mixture/removed = loc.remove_air(transfer_moles)
|
|
|
|
air2.merge(removed)
|
|
air_update_turf()
|
|
|
|
var/datum/pipeline/parent2 = PARENT2
|
|
parent2.update = 1
|
|
|
|
return 1
|
|
|
|
//Radio remote control
|
|
|
|
/obj/machinery/atmospherics/components/binary/dp_vent_pump/proc/set_frequency(new_frequency)
|
|
radio_controller.remove_object(src, frequency)
|
|
frequency = new_frequency
|
|
if(frequency)
|
|
radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
|
|
|
/obj/machinery/atmospherics/components/binary/dp_vent_pump/proc/broadcast_status()
|
|
if(!radio_connection)
|
|
return 0
|
|
|
|
var/datum/signal/signal = new
|
|
signal.transmission_method = 1 //radio signal
|
|
signal.source = src
|
|
|
|
signal.data = list(
|
|
"tag" = id,
|
|
"device" = "ADVP",
|
|
"power" = on,
|
|
"direction" = pump_direction?("release"):("siphon"),
|
|
"checks" = pressure_checks,
|
|
"input" = input_pressure_min,
|
|
"output" = output_pressure_max,
|
|
"external" = external_pressure_bound,
|
|
"sigtype" = "status"
|
|
)
|
|
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
|
|
|
return 1
|
|
|
|
/obj/machinery/atmospherics/components/binary/dp_vent_pump/atmosinit()
|
|
..()
|
|
if(frequency)
|
|
set_frequency(frequency)
|
|
broadcast_status()
|
|
|
|
/obj/machinery/atmospherics/components/binary/dp_vent_pump/receive_signal(datum/signal/signal)
|
|
|
|
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
|
return 0
|
|
if("power" in signal.data)
|
|
on = text2num(signal.data["power"])
|
|
|
|
if("power_toggle" in signal.data)
|
|
on = !on
|
|
|
|
if("set_direction" in signal.data)
|
|
pump_direction = text2num(signal.data["set_direction"])
|
|
|
|
if("checks" in signal.data)
|
|
pressure_checks = text2num(signal.data["checks"])
|
|
|
|
if("purge" in signal.data)
|
|
pressure_checks &= ~1
|
|
pump_direction = 0
|
|
|
|
if("stabalize" in signal.data)
|
|
pressure_checks |= 1
|
|
pump_direction = 1
|
|
|
|
if("set_input_pressure" in signal.data)
|
|
input_pressure_min = Clamp(text2num(signal.data["set_input_pressure"]),0,ONE_ATMOSPHERE*50)
|
|
|
|
if("set_output_pressure" in signal.data)
|
|
output_pressure_max = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
|
|
|
if("set_external_pressure" in signal.data)
|
|
external_pressure_bound = Clamp(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
|
|
|
|
if("status" in signal.data)
|
|
spawn(2)
|
|
broadcast_status()
|
|
return //do not update_icon
|
|
//if(signal.data["tag"])
|
|
spawn(2)
|
|
broadcast_status()
|
|
update_icon()
|
|
|
|
#undef EXT_BOUND
|
|
#undef INPUT_MIN
|
|
#undef OUTPUT_MAX |