diff --git a/code/__defines/machinery.dm b/code/__defines/machinery.dm index 7be4c8ddbb..5fc66791c6 100644 --- a/code/__defines/machinery.dm +++ b/code/__defines/machinery.dm @@ -3,8 +3,6 @@ var/global/defer_powernet_rebuild = 0 // True if net rebuild will be called #define CELLRATE 0.002 // Multiplier for watts per tick <> cell storage (e.g., 0.02 means if there is a load of 1000 watts, 20 units will be taken from a cell per second) // It's a conversion constant. power_used*CELLRATE = charge_provided, or charge_used/CELLRATE = power_provided -#define CHARGELEVEL_DEFAULT 0.0005 // Controls APC charge rates - // Doors! #define DOOR_CRUSH_DAMAGE 10 #define ALIEN_SELECT_AFK_BUFFER 1 // How many minutes that a person can be AFK before not being allowed to be an alien. diff --git a/code/modules/power/apc.dm b/code/modules/power/apc.dm index 8d08858246..8b4cb66f7c 100644 --- a/code/modules/power/apc.dm +++ b/code/modules/power/apc.dm @@ -63,6 +63,7 @@ var/area/area var/areastring = null var/obj/item/weapon/cell/cell + var/chargelevel = 0.0005 // Cap for how fast APC cells charge, as a percentage-per-tick (0.01 means cellcharge is capped to 1% per second) var/start_charge = 90 // initial cell charge % var/cell_type = /obj/item/weapon/cell/apc var/opened = 0 //0=closed, 1=opened, 2=cover removed @@ -104,7 +105,6 @@ var/global/list/status_overlays_equipment var/global/list/status_overlays_lighting var/global/list/status_overlays_environ - var/chargelevel = CHARGELEVEL_DEFAULT // Cap for how fast APC cells charge, as a percentage-per-tick (0.01 means cellcharge is capped to 1% per second) /obj/machinery/power/apc/updateDialog() if (stat & (BROKEN|MAINT))