Some cleanup for pumps and vent pumps
This commit is contained in:
@@ -80,35 +80,36 @@ Thus, the two variables affect pump operation are set in New():
|
||||
if(pressure_delta > 0.01 && (source.total_moles() > 0) && (source.temperature > 0 || sink.temperature > 0))
|
||||
//Figure out how much gas to transfer
|
||||
var/air_temperature = (sink.temperature > 0)? sink.temperature : source.temperature
|
||||
var/transfer_moles = calc_transfer_amount(pressure_delta)
|
||||
|
||||
//Calculate the amount of energy required
|
||||
var/specific_entropy = sink.specific_entropy() - source.specific_entropy() //air2 is gaining moles, air1 is loosing
|
||||
var/specific_power = 0 // W/mol
|
||||
var/output_volume = sink.volume
|
||||
if (network2 && network2.air_transient)
|
||||
output_volume = network2.air_transient.volume //use the network volume if we can get it
|
||||
|
||||
//If specific_entropy is < 0 then transfer_moles is limited by how powerful the pump is
|
||||
if (specific_entropy < 0)
|
||||
specific_power = -specific_entropy*air_temperature //how much power we need per mole
|
||||
transfer_moles = min(transfer_moles, active_power_usage / specific_power)
|
||||
//Return the number of moles that would have to be transfered to bring sink to the target pressure
|
||||
var/transfer_moles = pressure_delta*output_volume/(air_temperature * R_IDEAL_GAS_EQUATION)
|
||||
|
||||
//Actually transfer the gas
|
||||
var/input_pressure = source.return_pressure()
|
||||
|
||||
//Calculate the amount of energy required
|
||||
var/specific_power = calculate_specific_power(source, sink) //this has to be calculated before we modify any gas mixtures
|
||||
if (specific_power > 0)
|
||||
transfer_moles = min(transfer_moles, active_power_usage / specific_power)
|
||||
|
||||
var/power_draw = specific_power*transfer_moles
|
||||
|
||||
var/datum/gas_mixture/removed = source.remove(transfer_moles)
|
||||
if (input_pressure > 0)
|
||||
last_flow_rate = removed.total_moles()*R_IDEAL_GAS_EQUATION*removed.temperature/input_pressure
|
||||
last_flow_rate = (removed.total_moles()/(removed.total_moles() + source.total_moles()))*source.volume
|
||||
|
||||
if (power_draw > 0)
|
||||
sink.add_thermal_energy(power_draw)
|
||||
handle_power_draw(power_draw)
|
||||
last_power_draw = power_draw
|
||||
else
|
||||
handle_power_draw(idle_power_usage)
|
||||
last_power_draw = idle_power_usage
|
||||
|
||||
sink.merge(removed)
|
||||
|
||||
//If specific_entropy is < 0 then extra power needs to be supplied to move gas
|
||||
if (specific_entropy < 0)
|
||||
//pump draws power and heats gas according to 2nd law of thermodynamics
|
||||
var/power_draw = round(transfer_moles*specific_power)
|
||||
sink.add_thermal_energy(power_draw)
|
||||
handle_power_draw(power_draw)
|
||||
else
|
||||
handle_power_draw(idle_power_usage)
|
||||
|
||||
if(network1)
|
||||
network1.update = 1
|
||||
|
||||
@@ -120,19 +121,6 @@ Thus, the two variables affect pump operation are set in New():
|
||||
|
||||
return 1
|
||||
|
||||
/obj/machinery/atmospherics/binary/pump/proc/calc_transfer_amount(var/pressure_delta)
|
||||
var/datum/gas_mixture/source = air1
|
||||
var/datum/gas_mixture/sink = air2
|
||||
|
||||
var/air_temperature = (sink.temperature > 0)? sink.temperature : source.temperature
|
||||
|
||||
var/output_volume = sink.volume
|
||||
if (network2 && network2.air_transient)
|
||||
output_volume = network2.air_transient.volume //use the network volume if we can get it
|
||||
|
||||
//Return the number of moles that would have to be transfered to bring sink to the target pressure
|
||||
return pressure_delta*output_volume/(air_temperature * R_IDEAL_GAS_EQUATION)
|
||||
|
||||
//This proc handles power usages so that we only have to call use_power() when the pump is loaded but not at full load.
|
||||
/obj/machinery/atmospherics/binary/pump/proc/handle_power_draw(var/usage_amount)
|
||||
if (usage_amount > active_power_usage - 5)
|
||||
@@ -141,7 +129,7 @@ Thus, the two variables affect pump operation are set in New():
|
||||
update_use_power(1)
|
||||
|
||||
if (usage_amount > idle_power_usage)
|
||||
use_power(round(usage_amount)) //in practice it's pretty rare that we will get here, so calling use_power() is alright.
|
||||
use_power(usage_amount) //in practice it's pretty rare that we will get here, so calling use_power() is alright.
|
||||
|
||||
last_power_draw = usage_amount
|
||||
|
||||
|
||||
Reference in New Issue
Block a user