Adds a flow rate meter to pump UI
Also fixes a stupid merge error.
This commit is contained in:
@@ -28,7 +28,9 @@ Thus, the two variables affect pump operation are set in New():
|
|||||||
use_power = 1
|
use_power = 1
|
||||||
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
||||||
active_power_usage = 7500 //This also doubles as a measure of how powerful the pump is, in Watts. 7500 W ~ 10 HP
|
active_power_usage = 7500 //This also doubles as a measure of how powerful the pump is, in Watts. 7500 W ~ 10 HP
|
||||||
|
|
||||||
var/last_power_draw = 0 //for UI
|
var/last_power_draw = 0 //for UI
|
||||||
|
var/last_flow_rate = 0 //for UI
|
||||||
var/max_pressure_setting = 9000 //kPa
|
var/max_pressure_setting = 9000 //kPa
|
||||||
|
|
||||||
var/frequency = 0
|
var/frequency = 0
|
||||||
@@ -64,7 +66,10 @@ Thus, the two variables affect pump operation are set in New():
|
|||||||
update_underlays()
|
update_underlays()
|
||||||
|
|
||||||
/obj/machinery/atmospherics/binary/pump/process()
|
/obj/machinery/atmospherics/binary/pump/process()
|
||||||
// ..()
|
//reset these each iteration
|
||||||
|
last_power_draw = 0
|
||||||
|
last_flow_rate = 0
|
||||||
|
|
||||||
if(stat & (NOPOWER|BROKEN))
|
if(stat & (NOPOWER|BROKEN))
|
||||||
return
|
return
|
||||||
if(!on)
|
if(!on)
|
||||||
@@ -88,7 +93,7 @@ Thus, the two variables affect pump operation are set in New():
|
|||||||
var/pressure_delta = target_pressure - output_starting_pressure
|
var/pressure_delta = target_pressure - output_starting_pressure
|
||||||
var/transfer_moles = pressure_delta*output_volume/(air_temperature * R_IDEAL_GAS_EQUATION) //The number of moles that would have to be transfered to bring air2 to the target pressure
|
var/transfer_moles = pressure_delta*output_volume/(air_temperature * R_IDEAL_GAS_EQUATION) //The number of moles that would have to be transfered to bring air2 to the target pressure
|
||||||
|
|
||||||
//estimate the amount of energy required
|
//calculate the amount of energy required
|
||||||
var/specific_entropy = air2.specific_entropy() - air1.specific_entropy() //air2 is gaining moles, air1 is loosing
|
var/specific_entropy = air2.specific_entropy() - air1.specific_entropy() //air2 is gaining moles, air1 is loosing
|
||||||
var/specific_power = 0 // W/mol
|
var/specific_power = 0 // W/mol
|
||||||
|
|
||||||
@@ -99,6 +104,7 @@ Thus, the two variables affect pump operation are set in New():
|
|||||||
|
|
||||||
//Actually transfer the gas
|
//Actually transfer the gas
|
||||||
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
|
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
|
||||||
|
last_flow_rate = output_starting_pressure? transfer_moles*R_IDEAL_GAS_EQUATION*removed.temperature/air1.return_pressure() : 0 //need to calculate this here because gas_mixture/remove() is dumb
|
||||||
air2.merge(removed)
|
air2.merge(removed)
|
||||||
|
|
||||||
//if specific_entropy >= 0 then gas is flowing naturally and we don't need to use extra power
|
//if specific_entropy >= 0 then gas is flowing naturally and we don't need to use extra power
|
||||||
@@ -148,7 +154,7 @@ Thus, the two variables affect pump operation are set in New():
|
|||||||
|
|
||||||
|
|
||||||
//this proc handles power usages so that we only have to call use_power() when the pump is loaded but not at full load.
|
//this proc handles power usages so that we only have to call use_power() when the pump is loaded but not at full load.
|
||||||
/obj/machinery/atmospherics/binary/proc/update_power_usage(var/usage_amount)
|
/obj/machinery/atmospherics/binary/pump/proc/update_power_usage(var/usage_amount)
|
||||||
if (usage_amount > active_power_usage - 5)
|
if (usage_amount > active_power_usage - 5)
|
||||||
if (use_power < 2)
|
if (use_power < 2)
|
||||||
update_use_power(2)
|
update_use_power(2)
|
||||||
@@ -163,15 +169,6 @@ Thus, the two variables affect pump operation are set in New():
|
|||||||
if (use_power > 0)
|
if (use_power > 0)
|
||||||
last_power_draw = max(last_power_draw, idle_power_usage)
|
last_power_draw = max(last_power_draw, idle_power_usage)
|
||||||
|
|
||||||
/obj/machinery/atmospherics/binary/proc/turn_on()
|
|
||||||
on = 1
|
|
||||||
update_use_power(1)
|
|
||||||
|
|
||||||
/obj/machinery/atmospherics/binary/proc/turn_off()
|
|
||||||
on = 0
|
|
||||||
last_power_draw = 0
|
|
||||||
update_use_power(0)
|
|
||||||
|
|
||||||
/obj/machinery/atmospherics/binary/pump/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null)
|
/obj/machinery/atmospherics/binary/pump/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null)
|
||||||
if(stat & (BROKEN|NOPOWER))
|
if(stat & (BROKEN|NOPOWER))
|
||||||
return
|
return
|
||||||
@@ -181,8 +178,9 @@ Thus, the two variables affect pump operation are set in New():
|
|||||||
|
|
||||||
data = list(
|
data = list(
|
||||||
"on" = on,
|
"on" = on,
|
||||||
"pressure_set" = round(target_pressure, 0.01),
|
"pressure_set" = round(target_pressure, 0.05),
|
||||||
"max_pressure" = max_pressure_setting,
|
"max_pressure" = max_pressure_setting,
|
||||||
|
"last_flow_rate" = round(last_flow_rate),
|
||||||
"last_power_draw" = round(last_power_draw),
|
"last_power_draw" = round(last_power_draw),
|
||||||
"max_power_draw" = active_power_usage,
|
"max_power_draw" = active_power_usage,
|
||||||
)
|
)
|
||||||
@@ -206,17 +204,16 @@ Thus, the two variables affect pump operation are set in New():
|
|||||||
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
||||||
return 0
|
return 0
|
||||||
|
|
||||||
if("power" in signal.data)
|
if(signal.data["power"])
|
||||||
if(text2num(signal.data["power"]))
|
if(text2num(signal.data["power"]))
|
||||||
turn_on()
|
on = 1
|
||||||
else
|
else
|
||||||
turn_off()
|
on = 0
|
||||||
|
update_use_power(on)
|
||||||
|
|
||||||
if("power_toggle" in signal.data)
|
if("power_toggle" in signal.data)
|
||||||
if (on)
|
on = !on
|
||||||
turn_off()
|
update_use_power(on)
|
||||||
else
|
|
||||||
turn_on()
|
|
||||||
|
|
||||||
if(signal.data["set_output_pressure"])
|
if(signal.data["set_output_pressure"])
|
||||||
target_pressure = between(
|
target_pressure = between(
|
||||||
@@ -250,10 +247,8 @@ Thus, the two variables affect pump operation are set in New():
|
|||||||
if(..()) return
|
if(..()) return
|
||||||
|
|
||||||
if(href_list["power"])
|
if(href_list["power"])
|
||||||
if (on)
|
on = !on
|
||||||
turn_off()
|
update_use_power(on)
|
||||||
else
|
|
||||||
turn_on()
|
|
||||||
|
|
||||||
switch(href_list["set_press"])
|
switch(href_list["set_press"])
|
||||||
if ("min")
|
if ("min")
|
||||||
|
|||||||
@@ -12,11 +12,8 @@
|
|||||||
Desirable output pressure:
|
Desirable output pressure:
|
||||||
</div>
|
</div>
|
||||||
<div class="itemContent">
|
<div class="itemContent">
|
||||||
{{:~displayBar(pressure_set, 0, max_pressure)}}
|
|
||||||
<div style="clear: both; padding-top: 4px;">
|
<div style="clear: both; padding-top: 4px;">
|
||||||
{{:~link('MIN', null, {'set_press' : 'min'}, (pressure_set > 0) ? null : 'disabled')}}
|
|
||||||
{{:~link('SET', null, {'set_press' : 'set'}, null)}}
|
{{:~link('SET', null, {'set_press' : 'set'}, null)}}
|
||||||
{{:~link('MAX', null, {'set_press' : 'max'}, (pressure_set < max_pressure) ? null : 'disabled')}}
|
|
||||||
<div style="float: left; width: 80px; text-align: center;"> {{:pressure_set}} kPa </div>
|
<div style="float: left; width: 80px; text-align: center;"> {{:pressure_set}} kPa </div>
|
||||||
</div>
|
</div>
|
||||||
</div>
|
</div>
|
||||||
@@ -33,3 +30,14 @@
|
|||||||
</div>
|
</div>
|
||||||
</div>
|
</div>
|
||||||
</div>
|
</div>
|
||||||
|
|
||||||
|
<div class="item">
|
||||||
|
<div class="itemLabel">
|
||||||
|
Flow Rate:
|
||||||
|
</div>
|
||||||
|
<div class="itemContent">
|
||||||
|
<div class="statusValue">
|
||||||
|
{{:last_flow_rate}} L/s
|
||||||
|
</div>
|
||||||
|