mirror of
https://github.com/CHOMPStation2/CHOMPStation2.git
synced 2025-12-12 03:02:54 +00:00
Improves power monitor UI
Improves power monitor sensor list UI. Fixes #7449
This commit is contained in:
@@ -15,8 +15,9 @@
|
||||
anchored = 1.0
|
||||
circuit = /obj/item/weapon/circuitboard/powermonitor
|
||||
var/list/grid_sensors = null
|
||||
var/update_counter = 0 // Next icon update when this reaches 5 (ie every 5 ticks)
|
||||
var/active_sensor = null
|
||||
var/list/sensors_by_powernet = null
|
||||
var/update_counter = 0 // Next icon update when this reaches 5 (ie every 5 ticks)
|
||||
var/active_sensor = null //name_tag of the currently selected sensor
|
||||
use_power = 1
|
||||
idle_power_usage = 300
|
||||
active_power_usage = 300
|
||||
@@ -34,12 +35,19 @@
|
||||
|
||||
/obj/machinery/computer/power_monitor/proc/refresh_sensors()
|
||||
grid_sensors = list()
|
||||
sensors_by_powernet = list()
|
||||
for(var/obj/machinery/power/sensor/S in machines)
|
||||
if((S.loc.z == src.loc.z) || (S.long_range)) // Consoles have range on their Z-Level. Sensors with long_range var will work between Z levels.
|
||||
if(S.name_tag == "#UNKN#") // Default name. Shouldn't happen!
|
||||
error("Powernet sensor with unset ID Tag! [S.x]X [S.y]Y [S.z]Z")
|
||||
else
|
||||
grid_sensors += S
|
||||
grid_sensors[S.name_tag] = S
|
||||
|
||||
var/pnet = (S.powernet)? S.powernet : "none"
|
||||
if (pnet in sensors_by_powernet)
|
||||
sensors_by_powernet[pnet] += S
|
||||
else
|
||||
sensors_by_powernet[pnet] = list(S)
|
||||
|
||||
|
||||
/obj/machinery/computer/power_monitor/attack_ai(mob/user)
|
||||
@@ -75,13 +83,10 @@
|
||||
t += "<BR><A href='?src=\ref[src];close=1'>Close</A><BR><HR>"
|
||||
|
||||
if(!grid_sensors)
|
||||
t += "Unable to connect to sensor!"
|
||||
t += "No sensors available."
|
||||
else
|
||||
var/obj/machinery/power/sensor/OKS = null
|
||||
for(var/obj/machinery/power/sensor/S in grid_sensors)
|
||||
if(S.name_tag == active_sensor)
|
||||
OKS = S
|
||||
if(OKS)
|
||||
if (active_sensor in grid_sensors)
|
||||
var/obj/machinery/power/sensor/OKS = grid_sensors[active_sensor]
|
||||
t += "<B>[OKS.name_tag] - Sensor Reading</B><BR>"
|
||||
t += OKS.ReturnReading()
|
||||
else
|
||||
@@ -91,20 +96,36 @@
|
||||
else
|
||||
t += "<BR><A href='?src=\ref[src];update=1'>Refresh</A>"
|
||||
t += "<BR><A href='?src=\ref[src];close=1'>Close</A><BR><HR>"
|
||||
if((!grid_sensors) || (!grid_sensors.len))
|
||||
t += "<B>ERROR - No Active Sensors Detected!</B>"
|
||||
else
|
||||
for(var/obj/machinery/power/sensor/S in grid_sensors) // Show all data from current Z level.
|
||||
if(S.check_grid_warning()) // Display grids with active alarms in bold text
|
||||
t += "<B><A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A></B><BR>"
|
||||
else
|
||||
t += "<A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A><BR>"
|
||||
|
||||
|
||||
|
||||
t += render_sensor_list()
|
||||
|
||||
user << browse(t, "window=powcomp;size=600x900")
|
||||
onclose(user, "powcomp")
|
||||
|
||||
/obj/machinery/computer/power_monitor/proc/render_sensor_list()
|
||||
if((!grid_sensors) || (!grid_sensors.len))
|
||||
return "<B>ERROR - No Active Sensors Detected!</B>"
|
||||
|
||||
var/html = "<table border='0'><tr><th>Power Network</th><th>Sensors</th></tr>"
|
||||
for (var/pnet in sensors_by_powernet)
|
||||
if (pnet && pnet != "none")
|
||||
html += "<tr><td valign='top'>[uppertext("\ref[pnet]")]</td><td>"
|
||||
for(var/obj/machinery/power/sensor/S in sensors_by_powernet[pnet])
|
||||
//really, if one of them has a warning, they all should - but the interface doesn't guarantee that so whatever
|
||||
if(S.check_grid_warning()) // Display grids with active alarms in bold text
|
||||
html += "<B><A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A></B><BR>"
|
||||
else
|
||||
html += "<A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A><BR>"
|
||||
html += "</td></tr>"
|
||||
|
||||
if ("none" in sensors_by_powernet)
|
||||
html += "<tr><td>\[N/A\]</td><td>"
|
||||
for(var/obj/machinery/power/sensor/S in sensors_by_powernet["none"])
|
||||
html += "<A href='?src=\ref[src];setsensor=[S.name_tag]'>[S.name]</A><BR>"
|
||||
html += "</td></tr>"
|
||||
html += "</table>"
|
||||
|
||||
return html
|
||||
|
||||
/obj/machinery/computer/power_monitor/Topic(href, href_list)
|
||||
..()
|
||||
|
||||
Reference in New Issue
Block a user