mirror of
https://github.com/CHOMPStation2/CHOMPStation2.git
synced 2025-12-11 18:53:06 +00:00
Merge pull request #8794 from GinjaNinja32/atmos
Fixes atmos supply control consoles
This commit is contained in:
@@ -239,32 +239,32 @@ Max Output Pressure: [output_pressure] kPa<BR>"}
|
||||
if(href_list["in_refresh_status"])
|
||||
input_info = null
|
||||
signal.data = list ("tag" = input_tag, "status" = 1)
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
if(href_list["in_toggle_injector"])
|
||||
input_info = null
|
||||
signal.data = list ("tag" = input_tag, "power_toggle" = 1)
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
if(href_list["in_set_flowrate"])
|
||||
input_info = null
|
||||
signal.data = list ("tag" = input_tag, "set_volume_rate" = "[input_flow_setting]")
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
if(href_list["out_refresh_status"])
|
||||
output_info = null
|
||||
signal.data = list ("tag" = output_tag, "status" = 1)
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
if(href_list["out_toggle_power"])
|
||||
output_info = null
|
||||
signal.data = list ("tag" = output_tag, "power_toggle" = 1)
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
if(href_list["out_set_pressure"])
|
||||
output_info = null
|
||||
signal.data = list ("tag" = output_tag, "set_internal_pressure" = "[pressure_setting]")
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
signal.data["sigtype"]="command"
|
||||
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
||||
@@ -359,32 +359,32 @@ Min Core Pressure: [pressure_limit] kPa<BR>"}
|
||||
if(href_list["in_refresh_status"])
|
||||
input_info = null
|
||||
signal.data = list ("tag" = input_tag, "status" = 1)
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
if(href_list["in_toggle_injector"])
|
||||
input_info = null
|
||||
signal.data = list ("tag" = input_tag, "power_toggle" = 1)
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
if(href_list["in_set_flowrate"])
|
||||
input_info = null
|
||||
signal.data = list ("tag" = input_tag, "set_volume_rate" = "[input_flow_setting]")
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
if(href_list["out_refresh_status"])
|
||||
output_info = null
|
||||
signal.data = list ("tag" = output_tag, "status" = 1)
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
if(href_list["out_toggle_power"])
|
||||
output_info = null
|
||||
signal.data = list ("tag" = output_tag, "power_toggle" = 1)
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
if(href_list["out_set_pressure"])
|
||||
output_info = null
|
||||
signal.data = list ("tag" = output_tag, "set_external_pressure" = "[pressure_setting]", "checks" = 1)
|
||||
return 1
|
||||
. = 1
|
||||
|
||||
signal.data["sigtype"]="command"
|
||||
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
||||
|
||||
Reference in New Issue