Merge remote-tracking branch 'upstream/master' into dev-freeze

Conflicts:
	code/modules/hydroponics/seed_datums.dm
	code/modules/hydroponics/trays/tray_apiary.dm
	code/modules/power/apc.dm
	code/setup.dm
This commit is contained in:
PsiOmega
2015-02-27 08:58:55 +01:00
13 changed files with 114 additions and 100 deletions

View File

@@ -1148,44 +1148,9 @@
// Set channels depending on how much charge we have left
// Allow the APC to operate as normal if the cell can charge
if(charging && longtermpower < 10)
longtermpower += 1
else if(longtermpower > -10)
longtermpower -= 2
if((cell.percent() > 30) || longtermpower > 0) // Put most likely at the top so we don't check it last, effeciency 101
if(autoflag != 3)
equipment = autoset(equipment, 1)
lighting = autoset(lighting, 1)
environ = autoset(environ, 1)
autoflag = 3
power_alarm.clearAlarm(loc, src)
else if((cell.percent() <= 30) && (cell.percent() > 15) && longtermpower < 0) // <30%, turn off equipment
if(autoflag != 2)
equipment = autoset(equipment, 2)
lighting = autoset(lighting, 1)
environ = autoset(environ, 1)
power_alarm.triggerAlarm(loc, src)
autoflag = 2
else if(cell.percent() <= 15) // <15%, turn off lighting & equipment
if((autoflag > 1 && longtermpower < 0) || (autoflag > 1 && longtermpower >= 0))
equipment = autoset(equipment, 2)
lighting = autoset(lighting, 2)
environ = autoset(environ, 1)
power_alarm.triggerAlarm(loc, src)
autoflag = 1
else // zero charge, turn all off
if(autoflag != 0)
equipment = autoset(equipment, 0)
lighting = autoset(lighting, 0)
environ = autoset(environ, 0)
power_alarm.triggerAlarm(loc, src)
autoflag = 0
update_channels()
// now trickle-charge the cell
lastused_charging = 0 // Clear the variable for new use.
if(src.attempt_charging())
if(excess > 0) // check to make sure we have enough to charge
@@ -1222,7 +1187,6 @@
chargecount = 0
else // no cell, switch everything off
charging = 0
chargecount = 0
equipment = autoset(equipment, 0)
@@ -1232,13 +1196,48 @@
autoflag = 0
// update icon & area power if anything changed
if(last_lt != lighting || last_eq != equipment || last_en != environ)
queue_icon_update()
update()
else if (last_ch != charging)
queue_icon_update()
/obj/machinery/power/apc/proc/update_channels()
// Allow the APC to operate as normal if the cell can charge
if(charging && longtermpower < 10)
longtermpower += 1
else if(longtermpower > -10)
longtermpower -= 2
if((cell.percent() > 30) || longtermpower > 0) // Put most likely at the top so we don't check it last, effeciency 101
if(autoflag != 3)
equipment = autoset(equipment, 1)
lighting = autoset(lighting, 1)
environ = autoset(environ, 1)
autoflag = 3
power_alarm.clearAlarm(loc, src)
else if((cell.percent() <= 30) && (cell.percent() > 15) && longtermpower < 0) // <30%, turn off equipment
if(autoflag != 2)
equipment = autoset(equipment, 2)
lighting = autoset(lighting, 1)
environ = autoset(environ, 1)
power_alarm.triggerAlarm(loc, src)
autoflag = 2
else if(cell.percent() <= 15) // <15%, turn off lighting & equipment
if((autoflag > 1 && longtermpower < 0) || (autoflag > 1 && longtermpower >= 0))
equipment = autoset(equipment, 2)
lighting = autoset(lighting, 2)
environ = autoset(environ, 1)
power_alarm.triggerAlarm(loc, src)
autoflag = 1
else // zero charge, turn all off
if(autoflag != 0)
equipment = autoset(equipment, 0)
lighting = autoset(lighting, 0)
environ = autoset(environ, 0)
power_alarm.triggerAlarm(loc, src)
autoflag = 0
// val 0=off, 1=off(auto) 2=on 3=on(auto)
// on 0=off, 1=on, 2=autooff
@@ -1266,12 +1265,15 @@ obj/machinery/power/apc/proc/autoset(var/val, var/on)
cell.emp_act(severity)
if(occupier)
occupier.emp_act(severity)
lighting = 0
equipment = 0
environ = 0
update()
spawn(600)
equipment = 3
environ = 3
update_channels()
update()
..()
/obj/machinery/power/apc/ex_act(severity)