Fixes scrubber Phoron scrubbing

This commit is contained in:
Yoshax
2017-04-13 22:32:40 +01:00
parent df5099e51b
commit 91e060621d
2 changed files with 4 additions and 3 deletions

View File

@@ -19,7 +19,7 @@
var/hibernate = 0 //Do we even process? var/hibernate = 0 //Do we even process?
var/scrubbing = 1 //0 = siphoning, 1 = scrubbing var/scrubbing = 1 //0 = siphoning, 1 = scrubbing
var/list/scrubbing_gas = list("carbon_dioxide") var/list/scrubbing_gas = list("carbon_dioxide", "phoron")
var/panic = 0 //is this scrubber panicked? var/panic = 0 //is this scrubber panicked?

View File

@@ -93,7 +93,7 @@
req_access = list(access_rd, access_atmospherics, access_engine_equip) req_access = list(access_rd, access_atmospherics, access_engine_equip)
TLV["oxygen"] = list(-1.0, -1.0,-1.0,-1.0) // Partial pressure, kpa TLV["oxygen"] = list(-1.0, -1.0,-1.0,-1.0) // Partial pressure, kpa
TLV["carbon dioxide"] = list(-1.0, -1.0, 5, 10) // Partial pressure, kpa TLV["carbon dioxide"] = list(-1.0, -1.0, 5, 10) // Partial pressure, kpa
TLV["phoron"] = list(-1.0, -1.0, 0.2, 0.5) // Partial pressure, kpa TLV["phoron"] = list(-1.0, -1.0, 0, 0.5) // Partial pressure, kpa
TLV["other"] = list(-1.0, -1.0, 0.5, 1.0) // Partial pressure, kpa TLV["other"] = list(-1.0, -1.0, 0.5, 1.0) // Partial pressure, kpa
TLV["pressure"] = list(0,ONE_ATMOSPHERE*0.10,ONE_ATMOSPHERE*1.40,ONE_ATMOSPHERE*1.60) /* kpa */ TLV["pressure"] = list(0,ONE_ATMOSPHERE*0.10,ONE_ATMOSPHERE*1.40,ONE_ATMOSPHERE*1.60) /* kpa */
TLV["temperature"] = list(20, 40, 140, 160) // K TLV["temperature"] = list(20, 40, 140, 160) // K
@@ -121,7 +121,7 @@
// breathable air according to human/Life() // breathable air according to human/Life()
TLV["oxygen"] = list(16, 19, 135, 140) // Partial pressure, kpa TLV["oxygen"] = list(16, 19, 135, 140) // Partial pressure, kpa
TLV["carbon dioxide"] = list(-1.0, -1.0, 5, 10) // Partial pressure, kpa TLV["carbon dioxide"] = list(-1.0, -1.0, 5, 10) // Partial pressure, kpa
TLV["phoron"] = list(-1.0, -1.0, 0.2, 0.5) // Partial pressure, kpa TLV["phoron"] = list(-1.0, -1.0, 0, 0.5) // Partial pressure, kpa
TLV["other"] = list(-1.0, -1.0, 0.5, 1.0) // Partial pressure, kpa TLV["other"] = list(-1.0, -1.0, 0.5, 1.0) // Partial pressure, kpa
TLV["pressure"] = list(ONE_ATMOSPHERE * 0.80, ONE_ATMOSPHERE * 0.90, ONE_ATMOSPHERE * 1.10, ONE_ATMOSPHERE * 1.20) /* kpa */ TLV["pressure"] = list(ONE_ATMOSPHERE * 0.80, ONE_ATMOSPHERE * 0.90, ONE_ATMOSPHERE * 1.10, ONE_ATMOSPHERE * 1.20) /* kpa */
TLV["temperature"] = list(T0C - 26, T0C, T0C + 40, T0C + 66) // K TLV["temperature"] = list(T0C - 26, T0C, T0C + 40, T0C + 66) // K
@@ -758,6 +758,7 @@
user << "<span class='notice'>You [ locked ? "lock" : "unlock"] the Air Alarm interface.</span>" user << "<span class='notice'>You [ locked ? "lock" : "unlock"] the Air Alarm interface.</span>"
else else
user << "<span class='warning'>Access denied.</span>" user << "<span class='warning'>Access denied.</span>"
return
return ..() return ..()
/obj/machinery/alarm/power_change() /obj/machinery/alarm/power_change()