mirror of
https://github.com/CHOMPStation2/CHOMPStation2.git
synced 2025-12-10 18:22:39 +00:00
Merge pull request #7024 from atlantiscze/2020_04_21_ValveProgram
Converts Shutoff valve monitoring into a MC program
This commit is contained in:
@@ -5,66 +5,27 @@
|
|||||||
icon_screen = "power:0"
|
icon_screen = "power:0"
|
||||||
light_color = "#a97faa"
|
light_color = "#a97faa"
|
||||||
circuit = /obj/item/weapon/circuitboard/shutoff_monitor
|
circuit = /obj/item/weapon/circuitboard/shutoff_monitor
|
||||||
|
var/datum/nano_module/shutoff_monitor/monitor
|
||||||
|
|
||||||
/obj/machinery/computer/shutoff_monitor/attack_hand(var/mob/user)
|
/obj/machinery/computer/shutoff_monitor/New()
|
||||||
|
..()
|
||||||
|
monitor = new(src)
|
||||||
|
|
||||||
|
/obj/machinery/computer/shutoff_monitor/Destroy()
|
||||||
|
qdel(monitor)
|
||||||
|
monitor = null
|
||||||
|
..()
|
||||||
|
|
||||||
|
/obj/machinery/computer/shutoff_monitor/attack_hand(var/mob/user as mob)
|
||||||
..()
|
..()
|
||||||
ui_interact(user)
|
ui_interact(user)
|
||||||
|
|
||||||
/obj/machinery/computer/shutoff_monitor/attack_robot(var/mob/user) // Borgs and AI will want to see this too
|
/obj/machinery/computer/shutoff_monitor/ui_interact(mob/user, ui_key = "shutoff_monitor", var/datum/nanoui/ui = null, var/force_open = 1)
|
||||||
..()
|
monitor.ui_interact(user, ui_key, ui, force_open)
|
||||||
ui_interact(user)
|
|
||||||
|
|
||||||
/obj/machinery/computer/shutoff_monitor/attack_ai(var/mob/user)
|
|
||||||
ui_interact(user)
|
|
||||||
|
|
||||||
/obj/machinery/computer/shutoff_monitor/ui_interact(mob/user, ui_key = "shutoff_monitor", var/datum/nanoui/ui = null, var/force_open = 1, var/key_state = null)
|
|
||||||
var/data[0]
|
|
||||||
data["valves"] = list()
|
|
||||||
for(var/obj/machinery/atmospherics/valve/shutoff/S in GLOB.shutoff_valves)
|
|
||||||
data["valves"][++data["valves"].len] = list("name" = S.name, "enable" = S.close_on_leaks, "open" = S.open, "x" = S.x, "y" = S.y, "z" = S.z, "ref" = "\ref[S]")
|
|
||||||
|
|
||||||
// update the ui if it exists, returns null if no ui is passed/found
|
|
||||||
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, data, force_open)
|
|
||||||
if(!ui)
|
|
||||||
// the ui does not exist, so we'll create a new() one
|
|
||||||
// for a list of parameters and their descriptions see the code docs in \code\modules\nano\nanoui.dm
|
|
||||||
ui = new(user, src, ui_key, "shutoff_monitor.tmpl", "Automated Shutoff Valve Monitor", 625, 700, state = key_state)
|
|
||||||
// when the ui is first opened this is the data it will use
|
|
||||||
ui.set_initial_data(data)
|
|
||||||
// open the new ui window
|
|
||||||
ui.open()
|
|
||||||
// auto update every 20 Master Controller tick
|
|
||||||
ui.set_auto_update(20) // Longer term to reduce the rate of data collection and processing
|
|
||||||
|
|
||||||
/obj/machinery/computer/shutoff_monitor/Topic(href, href_list)
|
|
||||||
if(..())
|
|
||||||
return 1
|
|
||||||
|
|
||||||
if(href_list["toggle_enable"])
|
|
||||||
var/obj/machinery/atmospherics/valve/shutoff/S = locate(href_list["toggle_enable"])
|
|
||||||
|
|
||||||
// Invalid ref
|
|
||||||
if(!istype(S))
|
|
||||||
return 0
|
|
||||||
|
|
||||||
S.close_on_leaks = !S.close_on_leaks
|
|
||||||
|
|
||||||
if(href_list["toggle_open"])
|
|
||||||
var/obj/machinery/atmospherics/valve/shutoff/S = locate(href_list["toggle_open"])
|
|
||||||
|
|
||||||
// Invalid ref
|
|
||||||
if(!istype(S))
|
|
||||||
return 0
|
|
||||||
|
|
||||||
if(S.open)
|
|
||||||
S.close()
|
|
||||||
else
|
|
||||||
S.open()
|
|
||||||
|
|
||||||
return
|
|
||||||
|
|
||||||
|
|
||||||
/obj/machinery/computer/shutoff_monitor/update_icon()
|
/obj/machinery/computer/shutoff_monitor/update_icon()
|
||||||
..()
|
..()
|
||||||
if(!(stat & (NOPOWER|BROKEN)))
|
if(!(stat & (NOPOWER|BROKEN)))
|
||||||
add_overlay("ai-fixer-empty")
|
add_overlay("ai-fixer-empty")
|
||||||
|
else
|
||||||
|
cut_overlay("ai-fixer-empty")
|
||||||
@@ -15,6 +15,7 @@
|
|||||||
hard_drive.store_file(new/datum/computer_file/program/atmos_control())
|
hard_drive.store_file(new/datum/computer_file/program/atmos_control())
|
||||||
hard_drive.store_file(new/datum/computer_file/program/rcon_console())
|
hard_drive.store_file(new/datum/computer_file/program/rcon_console())
|
||||||
hard_drive.store_file(new/datum/computer_file/program/camera_monitor())
|
hard_drive.store_file(new/datum/computer_file/program/camera_monitor())
|
||||||
|
hard_drive.store_file(new/datum/computer_file/program/shutoff_monitor())
|
||||||
|
|
||||||
// Medical
|
// Medical
|
||||||
/obj/item/modular_computer/console/preset/medical/install_default_programs()
|
/obj/item/modular_computer/console/preset/medical/install_default_programs()
|
||||||
|
|||||||
@@ -0,0 +1,63 @@
|
|||||||
|
/datum/computer_file/program/shutoff_monitor
|
||||||
|
filename = "shutoffmonitor"
|
||||||
|
filedesc = "Shutoff Valve Monitoring"
|
||||||
|
nanomodule_path = /datum/nano_module/shutoff_monitor
|
||||||
|
program_icon_state = "atmos_control"
|
||||||
|
program_key_state = "atmos_key"
|
||||||
|
program_menu_icon = "wrench"
|
||||||
|
extended_desc = "This program allows for remote monitoring and control of emergency shutoff valves."
|
||||||
|
required_access = access_engine
|
||||||
|
requires_ntnet = 1
|
||||||
|
network_destination = "shutoff valve control computer"
|
||||||
|
size = 5
|
||||||
|
var/has_alert = 0
|
||||||
|
|
||||||
|
/datum/nano_module/shutoff_monitor
|
||||||
|
name = "Shutoff Valve Monitoring"
|
||||||
|
|
||||||
|
/datum/nano_module/shutoff_monitor/Topic(ref, href_list)
|
||||||
|
if(..())
|
||||||
|
return 1
|
||||||
|
|
||||||
|
if(href_list["toggle_enable"])
|
||||||
|
var/obj/machinery/atmospherics/valve/shutoff/S = locate(href_list["toggle_enable"])
|
||||||
|
if(!istype(S))
|
||||||
|
return 0
|
||||||
|
S.close_on_leaks = !S.close_on_leaks
|
||||||
|
return 1
|
||||||
|
|
||||||
|
if(href_list["toggle_open"])
|
||||||
|
var/obj/machinery/atmospherics/valve/shutoff/S = locate(href_list["toggle_open"])
|
||||||
|
if(!istype(S))
|
||||||
|
return 0
|
||||||
|
if(S.open)
|
||||||
|
S.close()
|
||||||
|
else
|
||||||
|
S.open()
|
||||||
|
return 1
|
||||||
|
|
||||||
|
/datum/nano_module/shutoff_monitor/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null, var/force_open = 1, var/datum/topic_state/state = default_state)
|
||||||
|
var/list/data = host.initial_data()
|
||||||
|
var/list/valves = list()
|
||||||
|
|
||||||
|
for(var/obj/machinery/atmospherics/valve/shutoff/S in GLOB.shutoff_valves)
|
||||||
|
valves.Add(list(list(
|
||||||
|
"name" = S.name,
|
||||||
|
"enabled" = S.close_on_leaks,
|
||||||
|
"open" = S.open,
|
||||||
|
"x" = S.x,
|
||||||
|
"y" = S.y,
|
||||||
|
"z" = S.z,
|
||||||
|
"ref" = "\ref[S]"
|
||||||
|
)))
|
||||||
|
|
||||||
|
data["valves"] = valves
|
||||||
|
|
||||||
|
ui = SSnanoui.try_update_ui(user, src, ui_key, ui, data, force_open)
|
||||||
|
if (!ui)
|
||||||
|
ui = new(user, src, ui_key, "shutoff_monitor.tmpl", "Shutoff Valve Monitoring", 627, 700, state = state)
|
||||||
|
if(host.update_layout()) // This is necessary to ensure the status bar remains updated along with rest of the UI.
|
||||||
|
ui.auto_update_layout = 1
|
||||||
|
ui.set_initial_data(data)
|
||||||
|
ui.open()
|
||||||
|
ui.set_auto_update(1)
|
||||||
5
html/changelogs/atlantiscze-valveprogram.yml
Normal file
5
html/changelogs/atlantiscze-valveprogram.yml
Normal file
@@ -0,0 +1,5 @@
|
|||||||
|
author: atlantiscze
|
||||||
|
delete-after: True
|
||||||
|
|
||||||
|
changes:
|
||||||
|
- rscadd: "Shutoff valve monitoring is now also available as a modular computer program. Its UI has also been cleaned up a little."
|
||||||
@@ -1,18 +1,13 @@
|
|||||||
<h2>Automated Shutoff Valve Monitoring Console</h2>
|
<h2>Automated Shutoff Valve Monitoring Console</h2>
|
||||||
<hr>
|
<hr>
|
||||||
|
<table style="width:100%"><tr><th>Name<th>Position<th>Open<th>Mode<th>Actions
|
||||||
{{for data.valves}}
|
{{for data.valves}}
|
||||||
<div class="item">
|
<tr>
|
||||||
<div class="itemLabel" style="width:45%;">
|
<td>{{:value.name}}
|
||||||
{{:value.name}}
|
<td>{{:value.x}}, {{:value.y}}, {{:value.z}}
|
||||||
</div>
|
<td>{{:value.open ? 'Yes' : 'No'}}
|
||||||
<div class="itemContent" style="width:55%;">
|
<td>{{:value.enabled ? 'Auto' : 'Manual'}}
|
||||||
<span style="display:inline-block;width:45%;min-width:150px;">
|
<td>{{:helper.link(value.open ? 'Close' : 'Open', null, {'toggle_open' : value.ref}, value.enabled ? 'disabled' : null)}}
|
||||||
{{:helper.link(value.open ? 'Open' : 'Closed', 'alert', {'toggle_open' : value.ref})}}
|
{{:helper.link(value.enabled ? 'Manual' : 'Auto', null, {'toggle_enable' : value.ref})}}
|
||||||
{{:helper.link(value.enable ? 'Enabled' : 'Disabled', 'alert', {'toggle_enable' : value.ref})}}
|
{{/for}}
|
||||||
</span>
|
</table>
|
||||||
<span style="display:inline-block;width:55%;min-width:150px;">
|
|
||||||
Coordinates: ({{:value.x}}, {{:value.y}}, {{:value.z}})
|
|
||||||
</span>
|
|
||||||
</div>
|
|
||||||
</div>
|
|
||||||
{{/for}}
|
|
||||||
@@ -2793,6 +2793,7 @@
|
|||||||
#include "code\modules\modular_computers\file_system\programs\engineering\atmos_control.dm"
|
#include "code\modules\modular_computers\file_system\programs\engineering\atmos_control.dm"
|
||||||
#include "code\modules\modular_computers\file_system\programs\engineering\power_monitor.dm"
|
#include "code\modules\modular_computers\file_system\programs\engineering\power_monitor.dm"
|
||||||
#include "code\modules\modular_computers\file_system\programs\engineering\rcon_console.dm"
|
#include "code\modules\modular_computers\file_system\programs\engineering\rcon_console.dm"
|
||||||
|
#include "code\modules\modular_computers\file_system\programs\engineering\shutoff_monitor.dm"
|
||||||
#include "code\modules\modular_computers\file_system\programs\engineering\supermatter_monitor.dm"
|
#include "code\modules\modular_computers\file_system\programs\engineering\supermatter_monitor.dm"
|
||||||
#include "code\modules\modular_computers\file_system\programs\generic\camera.dm"
|
#include "code\modules\modular_computers\file_system\programs\generic\camera.dm"
|
||||||
#include "code\modules\modular_computers\file_system\programs\generic\configurator.dm"
|
#include "code\modules\modular_computers\file_system\programs\generic\configurator.dm"
|
||||||
|
|||||||
Reference in New Issue