Fix construction of HE pipes, Vents, and Scrubbers Plus qdel issues.
The initialize() routines of HE pipes, vents an scrubbers need to be atmos_init() after all. If you register yourself with radio controller you need to de-register yourself too.
This commit is contained in:
@@ -47,6 +47,10 @@
|
||||
air2.volume = ATMOS_DEFAULT_VOLUME_PUMP
|
||||
icon = null
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/Destroy()
|
||||
unregister_radio(src, frequency)
|
||||
. = ..()
|
||||
|
||||
/obj/machinery/atmospherics/binary/dp_vent_pump/high_volume
|
||||