- SMES failures are now logged, including position of SMES, user and intensity of failure (from 1 to 100). Also included is JMP button.
- Instead of using ugly long string nice proc ping is used.
- Fixes issue with SMES overloads almost never causing APC failures.
- Atmospherics, north solar and outpost SMESs remapped to be of /smes/buildable type instead of /smes/ which can't be upgraded and/or disassembled.
- Added warning which shows in the log when non-magical or non-buildable SMES is mapped in/spawned. This should *hopefully* remind mappers that regular SMESs are not suposed to be mapped in unless specifically needed.
- Cleanup of SMES attackby() code
- Buildable SMESs now have option to override safety circuit by using multitool while the hatch is open.
- Disabling safeties lets you disassemble SMES even if it's charged above 1%.
- If charge is above 5% stored energy may discharge violently. This is percentage based (more energy = higher chance of this occuring + more severe consequences)
- Larger discharges affect whole powernet, burning out some lights and even completely destroying APCs!
- Substation PSUs act as surge protection. Thus, if set up properly damage is limited to few areas which are directly on the main grid (= maintenance mostly)
- STILL NEEDS TESTING. Pushing so other people can review the code and give further suggestions. And because i need to access it on second computer.
- Buildable SMES is now subtype of regular SMES.
- Buildable SMES related stuff moved to separate file (smes_construction.dm)
Please note that this commit is one of two commits which have to be applied together. Otherwise, compilation error occurs. (Code + Map. This one is Code)