//////////////////////////////////////// //CONTAINS: Air Alarms and Fire Alarms// //////////////////////////////////////// #define AALARM_MODE_SCRUBBING 1 #define AALARM_MODE_REPLACEMENT 2 //like scrubbing, but faster. #define AALARM_MODE_PANIC 3 //constantly sucks all air #define AALARM_MODE_CYCLE 4 //sucks off all air, then refill and switches to scrubbing #define AALARM_MODE_FILL 5 //emergency fill #define AALARM_MODE_OFF 6 //Shuts it all down. #define AALARM_SCREEN_MAIN 1 #define AALARM_SCREEN_VENT 2 #define AALARM_SCREEN_SCRUB 3 #define AALARM_SCREEN_MODE 4 #define AALARM_SCREEN_SENSORS 5 #define AALARM_REPORT_TIMEOUT 100 #define RCON_NO 1 #define RCON_AUTO 2 #define RCON_YES 3 #define MAX_TEMPERATURE 90 #define MIN_TEMPERATURE -40 //all air alarms in area are connected via magic /area var/obj/machinery/alarm/master_air_alarm var/list/air_vent_names = list() var/list/air_scrub_names = list() var/list/air_vent_info = list() var/list/air_scrub_info = list() /obj/machinery/alarm name = "alarm" desc = "Used to control various station atmospheric systems. The light indicates the current air status of the area." icon = 'icons/obj/monitors.dmi' icon_state = "alarm0" plane = TURF_PLANE layer = ABOVE_TURF_LAYER anchored = 1 use_power = 1 idle_power_usage = 80 active_power_usage = 1000 //For heating/cooling rooms. 1000 joules equates to about 1 degree every 2 seconds for a single tile of air. power_channel = ENVIRON req_one_access = list(access_atmospherics, access_engine_equip) var/alarm_id = null var/breach_detection = 1 // Whether to use automatic breach detection or not var/frequency = 1439 //var/skipprocess = 0 //Experimenting var/alarm_frequency = 1437 var/remote_control = 0 var/rcon_setting = 2 var/rcon_time = 0 var/locked = 1 panel_open = 0 // If it's been screwdrivered open. var/aidisabled = 0 var/shorted = 0 circuit = /obj/item/weapon/circuitboard/airalarm var/datum/wires/alarm/wires var/mode = AALARM_MODE_SCRUBBING var/screen = AALARM_SCREEN_MAIN var/area_uid var/area/alarm_area var/target_temperature = T0C+20 var/regulating_temperature = 0 var/datum/radio_frequency/radio_connection var/list/TLV = list() var/list/trace_gas = list("sleeping_agent", "volatile_fuel") //list of other gases that this air alarm is able to detect var/danger_level = 0 var/pressure_dangerlevel = 0 var/oxygen_dangerlevel = 0 var/co2_dangerlevel = 0 var/phoron_dangerlevel = 0 var/temperature_dangerlevel = 0 var/other_dangerlevel = 0 var/report_danger_level = 1 var/alarms_hidden = FALSE //If the alarms from this machine are visible on consoles /obj/machinery/alarm/nobreach breach_detection = 0 /obj/machinery/alarm/monitor report_danger_level = 0 breach_detection = 0 /obj/machinery/alarm/alarms_hidden alarms_hidden = TRUE /obj/machinery/alarm/server/New() ..() req_access = list(access_rd, access_atmospherics, access_engine_equip) TLV["oxygen"] = list(-1.0, -1.0,-1.0,-1.0) // Partial pressure, kpa TLV["carbon dioxide"] = list(-1.0, -1.0, 5, 10) // Partial pressure, kpa TLV["phoron"] = list(-1.0, -1.0, 0, 0.5) // Partial pressure, kpa TLV["other"] = list(-1.0, -1.0, 0.5, 1.0) // Partial pressure, kpa TLV["pressure"] = list(0,ONE_ATMOSPHERE*0.10,ONE_ATMOSPHERE*1.40,ONE_ATMOSPHERE*1.60) /* kpa */ TLV["temperature"] = list(20, 40, 140, 160) // K target_temperature = 90 /obj/machinery/alarm/Destroy() unregister_radio(src, frequency) qdel(wires) wires = null if(alarm_area && alarm_area.master_air_alarm == src) alarm_area.master_air_alarm = null elect_master(exclude_self = TRUE) return ..() /obj/machinery/alarm/New() ..() first_run() /obj/machinery/alarm/proc/first_run() alarm_area = get_area(src) area_uid = alarm_area.uid if(name == "alarm") name = "[alarm_area.name] Air Alarm" if(!wires) wires = new(src) // breathable air according to human/Life() TLV["oxygen"] = list(16, 19, 135, 140) // Partial pressure, kpa TLV["carbon dioxide"] = list(-1.0, -1.0, 5, 10) // Partial pressure, kpa TLV["phoron"] = list(-1.0, -1.0, 0, 0.5) // Partial pressure, kpa TLV["other"] = list(-1.0, -1.0, 0.5, 1.0) // Partial pressure, kpa TLV["pressure"] = list(ONE_ATMOSPHERE * 0.80, ONE_ATMOSPHERE * 0.90, ONE_ATMOSPHERE * 1.10, ONE_ATMOSPHERE * 1.20) /* kpa */ TLV["temperature"] = list(T0C - 26, T0C, T0C + 40, T0C + 66) // K /obj/machinery/alarm/Initialize() . = ..() set_frequency(frequency) if(!master_is_operating()) elect_master() /obj/machinery/alarm/process() if((stat & (NOPOWER|BROKEN)) || shorted) return var/turf/simulated/location = src.loc if(!istype(location)) return//returns if loc is not simulated var/datum/gas_mixture/environment = location.return_air() //Handle temperature adjustment here. handle_heating_cooling(environment) var/old_level = danger_level var/old_pressurelevel = pressure_dangerlevel danger_level = overall_danger_level(environment) if(old_level != danger_level) apply_danger_level(danger_level) if(old_pressurelevel != pressure_dangerlevel) if(breach_detected()) mode = AALARM_MODE_OFF apply_mode() if(mode == AALARM_MODE_CYCLE && environment.return_pressure() < ONE_ATMOSPHERE * 0.05) mode = AALARM_MODE_FILL apply_mode() //atmos computer remote controll stuff switch(rcon_setting) if(RCON_NO) remote_control = 0 if(RCON_AUTO) if(danger_level == 2) remote_control = 1 else remote_control = 0 if(RCON_YES) remote_control = 1 return /obj/machinery/alarm/proc/handle_heating_cooling(var/datum/gas_mixture/environment) if(!regulating_temperature) //check for when we should start adjusting temperature if(!get_danger_level(target_temperature, TLV["temperature"]) && abs(environment.temperature - target_temperature) > 2.0) update_use_power(2) regulating_temperature = 1 audible_message("\The [src] clicks as it starts [environment.temperature > target_temperature ? "cooling" : "heating"] the room.",\ "You hear a click and a faint electronic hum.") playsound(src.loc, 'sound/machines/click.ogg', 50, 1) else //check for when we should stop adjusting temperature if(get_danger_level(target_temperature, TLV["temperature"]) || abs(environment.temperature - target_temperature) <= 0.5) update_use_power(1) regulating_temperature = 0 audible_message("\The [src] clicks quietly as it stops [environment.temperature > target_temperature ? "cooling" : "heating"] the room.",\ "You hear a click as a faint electronic humming stops.") playsound(src.loc, 'sound/machines/click.ogg', 50, 1) if(regulating_temperature) if(target_temperature > T0C + MAX_TEMPERATURE) target_temperature = T0C + MAX_TEMPERATURE if(target_temperature < T0C + MIN_TEMPERATURE) target_temperature = T0C + MIN_TEMPERATURE var/datum/gas_mixture/gas gas = environment.remove(0.25 * environment.total_moles) if(gas) if(gas.temperature <= target_temperature) //gas heating var/energy_used = min(gas.get_thermal_energy_change(target_temperature) , active_power_usage) gas.add_thermal_energy(energy_used) //use_power(energy_used, ENVIRON) //handle by update_use_power instead else //gas cooling var/heat_transfer = min(abs(gas.get_thermal_energy_change(target_temperature)), active_power_usage) //Assume the heat is being pumped into the hull which is fixed at 20 C //none of this is really proper thermodynamics but whatever var/cop = gas.temperature / T20C //coefficient of performance -> power used = heat_transfer/cop heat_transfer = min(heat_transfer, cop * active_power_usage) //this ensures that we don't use more than active_power_usage amount of power heat_transfer = -gas.add_thermal_energy(-heat_transfer) //get the actual heat transfer //use_power(heat_transfer / cop, ENVIRON) //handle by update_use_power instead environment.merge(gas) /obj/machinery/alarm/proc/overall_danger_level(var/datum/gas_mixture/environment) var/partial_pressure = R_IDEAL_GAS_EQUATION * environment.temperature/environment.volume var/environment_pressure = environment.return_pressure() var/other_moles = 0 for(var/g in trace_gas) other_moles += environment.gas[g] //this is only going to be used in a partial pressure calc, so we don't need to worry about group_multiplier here. pressure_dangerlevel = get_danger_level(environment_pressure, TLV["pressure"]) oxygen_dangerlevel = get_danger_level(environment.gas["oxygen"]*partial_pressure, TLV["oxygen"]) co2_dangerlevel = get_danger_level(environment.gas["carbon_dioxide"]*partial_pressure, TLV["carbon dioxide"]) phoron_dangerlevel = get_danger_level(environment.gas["phoron"]*partial_pressure, TLV["phoron"]) temperature_dangerlevel = get_danger_level(environment.temperature, TLV["temperature"]) other_dangerlevel = get_danger_level(other_moles*partial_pressure, TLV["other"]) return max( pressure_dangerlevel, oxygen_dangerlevel, co2_dangerlevel, phoron_dangerlevel, other_dangerlevel, temperature_dangerlevel ) // Returns whether this air alarm thinks there is a breach, given the sensors that are available to it. /obj/machinery/alarm/proc/breach_detected() var/turf/simulated/location = src.loc if(!istype(location)) return 0 if(breach_detection == 0) return 0 var/datum/gas_mixture/environment = location.return_air() var/environment_pressure = environment.return_pressure() var/pressure_levels = TLV["pressure"] if(environment_pressure <= pressure_levels[1]) //low pressures if(!(mode == AALARM_MODE_PANIC || mode == AALARM_MODE_CYCLE)) playsound(src.loc, 'sound/machines/airalarm.ogg', 25, 0, 4) return 1 return 0 /obj/machinery/alarm/proc/master_is_operating() return alarm_area && alarm_area.master_air_alarm && !(alarm_area.master_air_alarm.stat & (NOPOWER | BROKEN)) /obj/machinery/alarm/proc/elect_master(exclude_self = FALSE) for(var/obj/machinery/alarm/AA in alarm_area) if(exclude_self && AA == src) continue if(!(AA.stat & (NOPOWER|BROKEN))) alarm_area.master_air_alarm = AA return 1 return 0 /obj/machinery/alarm/proc/get_danger_level(var/current_value, var/list/danger_levels) if((current_value >= danger_levels[4] && danger_levels[4] > 0) || current_value <= danger_levels[1]) return 2 if((current_value >= danger_levels[3] && danger_levels[3] > 0) || current_value <= danger_levels[2]) return 1 return 0 /obj/machinery/alarm/update_icon() if(panel_open) icon_state = "alarmx" set_light(0) return if((stat & (NOPOWER|BROKEN)) || shorted) icon_state = "alarmp" set_light(0) return var/icon_level = danger_level if(alarm_area.atmosalm) icon_level = max(icon_level, 1) //if there's an atmos alarm but everything is okay locally, no need to go past yellow var/new_color = null switch(icon_level) if(0) icon_state = "alarm0" new_color = "#03A728" if(1) icon_state = "alarm2" //yes, alarm2 is yellow alarm new_color = "#EC8B2F" if(2) icon_state = "alarm1" new_color = "#DA0205" set_light(l_range = 2, l_power = 0.25, l_color = new_color) /obj/machinery/alarm/receive_signal(datum/signal/signal) if(stat & (NOPOWER|BROKEN)) return if(alarm_area.master_air_alarm != src) if(master_is_operating()) return elect_master() if(alarm_area.master_air_alarm != src) return if(!signal || signal.encryption) return var/id_tag = signal.data["tag"] if(!id_tag) return if(signal.data["area"] != area_uid) return if(signal.data["sigtype"] != "status") return var/dev_type = signal.data["device"] if(!(id_tag in alarm_area.air_scrub_names) && !(id_tag in alarm_area.air_vent_names)) register_env_machine(id_tag, dev_type) if(dev_type == "AScr") alarm_area.air_scrub_info[id_tag] = signal.data else if(dev_type == "AVP") alarm_area.air_vent_info[id_tag] = signal.data /obj/machinery/alarm/proc/register_env_machine(var/m_id, var/device_type) var/new_name if(device_type == "AVP") new_name = "[alarm_area.name] Vent Pump #[alarm_area.air_vent_names.len+1]" alarm_area.air_vent_names[m_id] = new_name else if(device_type == "AScr") new_name = "[alarm_area.name] Air Scrubber #[alarm_area.air_scrub_names.len+1]" alarm_area.air_scrub_names[m_id] = new_name else return spawn(10) send_signal(m_id, list("init" = new_name)) /obj/machinery/alarm/proc/refresh_all() for(var/id_tag in alarm_area.air_vent_names) var/list/I = alarm_area.air_vent_info[id_tag] if(I && I["timestamp"] + AALARM_REPORT_TIMEOUT / 2 > world.time) continue send_signal(id_tag, list("status")) for(var/id_tag in alarm_area.air_scrub_names) var/list/I = alarm_area.air_scrub_info[id_tag] if(I && I["timestamp"] + AALARM_REPORT_TIMEOUT / 2 > world.time) continue send_signal(id_tag, list("status")) /obj/machinery/alarm/proc/set_frequency(new_frequency) radio_controller.remove_object(src, frequency) frequency = new_frequency radio_connection = radio_controller.add_object(src, frequency, RADIO_TO_AIRALARM) /obj/machinery/alarm/proc/send_signal(var/target, var/list/command)//sends signal 'command' to 'target'. Returns 0 if no radio connection, 1 otherwise if(!radio_connection) return 0 var/datum/signal/signal = new signal.transmission_method = 1 //radio signal signal.source = src signal.data = command signal.data["tag"] = target signal.data["sigtype"] = "command" radio_connection.post_signal(src, signal, RADIO_FROM_AIRALARM) // to_world("Signal [command] Broadcasted to [target]") return 1 /obj/machinery/alarm/proc/apply_mode() //propagate mode to other air alarms in the area //TODO: make it so that players can choose between applying the new mode to the room they are in (related area) vs the entire alarm area for(var/obj/machinery/alarm/AA in alarm_area) AA.mode = mode switch(mode) if(AALARM_MODE_SCRUBBING) for(var/device_id in alarm_area.air_scrub_names) send_signal(device_id, list("power"= 1, "co2_scrub"= 1, "scrubbing"= 1, "panic_siphon"= 0)) for(var/device_id in alarm_area.air_vent_names) send_signal(device_id, list("power"= 1, "checks"= "default", "set_external_pressure"= "default")) if(AALARM_MODE_PANIC, AALARM_MODE_CYCLE) for(var/device_id in alarm_area.air_scrub_names) send_signal(device_id, list("power"= 1, "panic_siphon"= 1)) for(var/device_id in alarm_area.air_vent_names) send_signal(device_id, list("power"= 0)) if(AALARM_MODE_REPLACEMENT) for(var/device_id in alarm_area.air_scrub_names) send_signal(device_id, list("power"= 1, "panic_siphon"= 1)) for(var/device_id in alarm_area.air_vent_names) send_signal(device_id, list("power"= 1, "checks"= "default", "set_external_pressure"= "default")) if(AALARM_MODE_FILL) for(var/device_id in alarm_area.air_scrub_names) send_signal(device_id, list("power"= 0)) for(var/device_id in alarm_area.air_vent_names) send_signal(device_id, list("power"= 1, "checks"= "default", "set_external_pressure"= "default")) if(AALARM_MODE_OFF) for(var/device_id in alarm_area.air_scrub_names) send_signal(device_id, list("power"= 0)) for(var/device_id in alarm_area.air_vent_names) send_signal(device_id, list("power"= 0)) /obj/machinery/alarm/proc/apply_danger_level(var/new_danger_level) if(report_danger_level && alarm_area.atmosalert(new_danger_level, src)) post_alert(new_danger_level) update_icon() /obj/machinery/alarm/proc/post_alert(alert_level) var/datum/radio_frequency/frequency = radio_controller.return_frequency(alarm_frequency) if(!frequency) return var/datum/signal/alert_signal = new alert_signal.source = src alert_signal.transmission_method = 1 alert_signal.data["zone"] = alarm_area.name alert_signal.data["type"] = "Atmospheric" if(alert_level==2) alert_signal.data["alert"] = "severe" else if(alert_level==1) alert_signal.data["alert"] = "minor" else if(alert_level==0) alert_signal.data["alert"] = "clear" frequency.post_signal(src, alert_signal) /obj/machinery/alarm/attack_ai(mob/user) ui_interact(user) /obj/machinery/alarm/attack_hand(mob/user) . = ..() if(.) return return interact(user) /obj/machinery/alarm/interact(mob/user) ui_interact(user) wires.Interact(user) /obj/machinery/alarm/ui_interact(mob/user, ui_key = "main", datum/nanoui/ui = null, force_open = 1, var/master_ui = null, var/datum/topic_state/state = default_state) var/data[0] var/remote_connection = 0 var/remote_access = 0 if(state) var/list/href = state.href_list(user) remote_connection = href["remote_connection"] // Remote connection means we're non-adjacent/connecting from another computer remote_access = href["remote_access"] // Remote access means we also have the privilege to alter the air alarm. data["locked"] = locked && !issilicon(user) data["remote_connection"] = remote_connection data["remote_access"] = remote_access data["rcon"] = rcon_setting data["screen"] = screen populate_status(data) if(!(locked && !remote_connection) || remote_access || issilicon(user)) populate_controls(data) ui = SSnanoui.try_update_ui(user, src, ui_key, ui, data, force_open) if(!ui) ui = new(user, src, ui_key, "air_alarm.tmpl", name, 325, 625, master_ui = master_ui, state = state) ui.set_initial_data(data) ui.open() ui.set_auto_update(1) /obj/machinery/alarm/proc/populate_status(var/data) var/turf/location = get_turf(src) var/datum/gas_mixture/environment = location.return_air() var/total = environment.total_moles var/list/environment_data = new data["has_environment"] = total if(total) var/pressure = environment.return_pressure() environment_data[++environment_data.len] = list("name" = "Pressure", "value" = pressure, "unit" = "kPa", "danger_level" = pressure_dangerlevel) environment_data[++environment_data.len] = list("name" = "Oxygen", "value" = environment.gas["oxygen"] / total * 100, "unit" = "%", "danger_level" = oxygen_dangerlevel) environment_data[++environment_data.len] = list("name" = "Carbon dioxide", "value" = environment.gas["carbon_dioxide"] / total * 100, "unit" = "%", "danger_level" = co2_dangerlevel) environment_data[++environment_data.len] = list("name" = "Toxins", "value" = environment.gas["phoron"] / total * 100, "unit" = "%", "danger_level" = phoron_dangerlevel) environment_data[++environment_data.len] = list("name" = "Temperature", "value" = environment.temperature, "unit" = "K ([round(environment.temperature - T0C, 0.1)]C)", "danger_level" = temperature_dangerlevel) data["total_danger"] = danger_level data["environment"] = environment_data data["atmos_alarm"] = alarm_area.atmosalm data["fire_alarm"] = alarm_area.fire != null data["target_temperature"] = "[target_temperature - T0C]C" /obj/machinery/alarm/proc/populate_controls(var/list/data) switch(screen) if(AALARM_SCREEN_MAIN) data["mode"] = mode if(AALARM_SCREEN_VENT) var/vents[0] for(var/id_tag in alarm_area.air_vent_names) var/long_name = alarm_area.air_vent_names[id_tag] var/list/info = alarm_area.air_vent_info[id_tag] if(!info) continue vents[++vents.len] = list( "id_tag" = id_tag, "long_name" = sanitize(long_name), "power" = info["power"], "checks" = info["checks"], "direction" = info["direction"], "external" = info["external"] ) data["vents"] = vents if(AALARM_SCREEN_SCRUB) var/scrubbers[0] for(var/id_tag in alarm_area.air_scrub_names) var/long_name = alarm_area.air_scrub_names[id_tag] var/list/info = alarm_area.air_scrub_info[id_tag] if(!info) continue scrubbers[++scrubbers.len] = list( "id_tag" = id_tag, "long_name" = sanitize(long_name), "power" = info["power"], "scrubbing" = info["scrubbing"], "panic" = info["panic"], "filters" = list() ) scrubbers[scrubbers.len]["filters"] += list(list("name" = "Oxygen", "command" = "o2_scrub", "val" = info["filter_o2"])) scrubbers[scrubbers.len]["filters"] += list(list("name" = "Nitrogen", "command" = "n2_scrub", "val" = info["filter_n2"])) scrubbers[scrubbers.len]["filters"] += list(list("name" = "Carbon Dioxide", "command" = "co2_scrub","val" = info["filter_co2"])) scrubbers[scrubbers.len]["filters"] += list(list("name" = "Toxin" , "command" = "tox_scrub","val" = info["filter_phoron"])) scrubbers[scrubbers.len]["filters"] += list(list("name" = "Nitrous Oxide", "command" = "n2o_scrub","val" = info["filter_n2o"])) scrubbers[scrubbers.len]["filters"] += list(list("name" = "Fuel", "command" = "fuel_scrub","val" = info["filter_fuel"])) data["scrubbers"] = scrubbers if(AALARM_SCREEN_MODE) var/modes[0] modes[++modes.len] = list("name" = "Filtering - Scrubs out contaminants", "mode" = AALARM_MODE_SCRUBBING, "selected" = mode == AALARM_MODE_SCRUBBING, "danger" = 0) modes[++modes.len] = list("name" = "Replace Air - Siphons out air while replacing", "mode" = AALARM_MODE_REPLACEMENT, "selected" = mode == AALARM_MODE_REPLACEMENT, "danger" = 0) modes[++modes.len] = list("name" = "Panic - Siphons air out of the room", "mode" = AALARM_MODE_PANIC, "selected" = mode == AALARM_MODE_PANIC, "danger" = 1) modes[++modes.len] = list("name" = "Cycle - Siphons air before replacing", "mode" = AALARM_MODE_CYCLE, "selected" = mode == AALARM_MODE_CYCLE, "danger" = 1) modes[++modes.len] = list("name" = "Fill - Shuts off scrubbers and opens vents", "mode" = AALARM_MODE_FILL, "selected" = mode == AALARM_MODE_FILL, "danger" = 0) modes[++modes.len] = list("name" = "Off - Shuts off vents and scrubbers", "mode" = AALARM_MODE_OFF, "selected" = mode == AALARM_MODE_OFF, "danger" = 0) data["modes"] = modes data["mode"] = mode if(AALARM_SCREEN_SENSORS) var/list/selected var/thresholds[0] var/list/gas_names = list( "oxygen" = "O2", "carbon dioxide" = "CO2", "phoron" = "Toxin", "other" = "Other") for(var/g in gas_names) thresholds[++thresholds.len] = list("name" = gas_names[g], "settings" = list()) selected = TLV[g] for(var/i = 1, i <= 4, i++) thresholds[thresholds.len]["settings"] += list(list("env" = g, "val" = i, "selected" = selected[i])) selected = TLV["pressure"] thresholds[++thresholds.len] = list("name" = "Pressure", "settings" = list()) for(var/i = 1, i <= 4, i++) thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = i, "selected" = selected[i])) selected = TLV["temperature"] thresholds[++thresholds.len] = list("name" = "Temperature", "settings" = list()) for(var/i = 1, i <= 4, i++) thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = i, "selected" = selected[i])) data["thresholds"] = thresholds /obj/machinery/alarm/CanUseTopic(var/mob/user, var/datum/topic_state/state, var/href_list = list()) if(aidisabled && isAI(user)) to_chat(user, "AI control for \the [src] interface has been disabled.") return STATUS_CLOSE . = shorted ? STATUS_DISABLED : STATUS_INTERACTIVE if(. == STATUS_INTERACTIVE) var/extra_href = state.href_list(usr) // Prevent remote users from altering RCON settings unless they already have access if(href_list["rcon"] && extra_href["remote_connection"] && !extra_href["remote_access"]) . = STATUS_UPDATE return min(..(), .) /obj/machinery/alarm/Topic(href, href_list, var/datum/topic_state/state) if(..(href, href_list, state)) return 1 // hrefs that can always be called -walter0o if(href_list["rcon"]) var/attempted_rcon_setting = text2num(href_list["rcon"]) switch(attempted_rcon_setting) if(RCON_NO) rcon_setting = RCON_NO if(RCON_AUTO) rcon_setting = RCON_AUTO if(RCON_YES) rcon_setting = RCON_YES return 1 if(href_list["temperature"]) var/list/selected = TLV["temperature"] var/max_temperature = min(selected[3] - T0C, MAX_TEMPERATURE) var/min_temperature = max(selected[2] - T0C, MIN_TEMPERATURE) var/input_temperature = input("What temperature would you like the system to mantain? (Capped between [min_temperature] and [max_temperature]C)", "Thermostat Controls", target_temperature - T0C) as num|null if(isnum(input_temperature)) if(input_temperature > max_temperature || input_temperature < min_temperature) to_chat(usr, "Temperature must be between [min_temperature]C and [max_temperature]C") else target_temperature = input_temperature + T0C return 1 // hrefs that need the AA unlocked -walter0o var/extra_href = state.href_list(usr) if(!(locked && !extra_href["remote_connection"]) || extra_href["remote_access"] || issilicon(usr)) if(href_list["command"]) var/device_id = href_list["id_tag"] switch(href_list["command"]) if("set_external_pressure") var/input_pressure = input("What pressure you like the system to mantain?", "Pressure Controls") as num|null if(isnum(input_pressure)) send_signal(device_id, list(href_list["command"] = input_pressure)) return 1 if("reset_external_pressure") send_signal(device_id, list(href_list["command"] = ONE_ATMOSPHERE)) return 1 if( "power", "adjust_external_pressure", "checks", "o2_scrub", "n2_scrub", "co2_scrub", "tox_scrub", "n2o_scrub", "fuel_scrub", "panic_siphon", "scrubbing", "direction") send_signal(device_id, list(href_list["command"] = text2num(href_list["val"]))) return 1 if("set_threshold") var/env = href_list["env"] var/threshold = text2num(href_list["var"]) var/list/selected = TLV[env] var/list/thresholds = list("lower bound", "low warning", "high warning", "upper bound") var/newval = input("Enter [thresholds[threshold]] for [env]", "Alarm triggers", selected[threshold]) as null | num if(isnull(newval)) return 1 if(newval<0) selected[threshold] = -1.0 else if(env=="temperature" && newval>5000) selected[threshold] = 5000 else if(env=="pressure" && newval>50*ONE_ATMOSPHERE) selected[threshold] = 50*ONE_ATMOSPHERE else if(env!="temperature" && env!="pressure" && newval>200) selected[threshold] = 200 else newval = round(newval,0.01) selected[threshold] = newval if(threshold == 1) if(selected[1] > selected[2]) selected[2] = selected[1] if(selected[1] > selected[3]) selected[3] = selected[1] if(selected[1] > selected[4]) selected[4] = selected[1] if(threshold == 2) if(selected[1] > selected[2]) selected[1] = selected[2] if(selected[2] > selected[3]) selected[3] = selected[2] if(selected[2] > selected[4]) selected[4] = selected[2] if(threshold == 3) if(selected[1] > selected[3]) selected[1] = selected[3] if(selected[2] > selected[3]) selected[2] = selected[3] if(selected[3] > selected[4]) selected[4] = selected[3] if(threshold == 4) if(selected[1] > selected[4]) selected[1] = selected[4] if(selected[2] > selected[4]) selected[2] = selected[4] if(selected[3] > selected[4]) selected[3] = selected[4] apply_mode() return 1 if(href_list["screen"]) screen = text2num(href_list["screen"]) return 1 if(href_list["atmos_unlock"]) switch(href_list["atmos_unlock"]) if("0") alarm_area.firedoors_close() if("1") alarm_area.firedoors_open() return 1 if(href_list["atmos_alarm"]) if(alarm_area.atmosalert(2, src)) apply_danger_level(2) update_icon() return 1 if(href_list["atmos_reset"]) if(alarm_area.atmosalert(0, src)) apply_danger_level(0) update_icon() return 1 if(href_list["mode"]) mode = text2num(href_list["mode"]) apply_mode() return 1 /obj/machinery/alarm/attackby(obj/item/W as obj, mob/user as mob) add_fingerprint(user) if(alarm_deconstruction_screwdriver(user, W)) return if(alarm_deconstruction_wirecutters(user, W)) return if(istype(W, /obj/item/weapon/card/id) || istype(W, /obj/item/device/pda))// trying to unlock the interface with an ID card togglelock() return ..() /obj/machinery/alarm/verb/togglelock(mob/user as mob) if(stat & (NOPOWER|BROKEN)) to_chat(user, "It does nothing.") return else if(allowed(usr) && !wires.IsIndexCut(AALARM_WIRE_IDSCAN)) locked = !locked to_chat(user, "You [locked ? "lock" : "unlock"] the Air Alarm interface.") else to_chat(user, "Access denied.") return /obj/machinery/alarm/AltClick() ..() togglelock() /obj/machinery/alarm/power_change() ..() spawn(rand(0,15)) update_icon() /obj/machinery/alarm/examine(mob/user) ..(user) /* AIR ALARM CIRCUIT Just a object used in constructing air alarms /obj/item/weapon/airalarm_electronics name = "air alarm electronics" icon = 'icons/obj/doors/door_assembly.dmi' icon_state = "door_electronics" desc = "Looks like a circuit. Probably is." w_class = ITEMSIZE_SMALL matter = list(DEFAULT_WALL_MATERIAL = 50, "glass" = 50) */ /* FIRE ALARM */ /obj/machinery/firealarm name = "fire alarm" desc = "\"Pull this in case of emergency\". Thus, keep pulling it forever." icon = 'icons/obj/monitors.dmi' icon_state = "fire0" plane = TURF_PLANE layer = ABOVE_TURF_LAYER var/detecting = 1.0 var/working = 1.0 var/time = 10.0 var/timing = 0.0 var/lockdownbyai = 0 anchored = 1.0 use_power = 1 idle_power_usage = 2 active_power_usage = 6 power_channel = ENVIRON var/last_process = 0 panel_open = 0 var/seclevel circuit = /obj/item/weapon/circuitboard/firealarm var/alarms_hidden = FALSE //If the alarms from this machine are visible on consoles /obj/machinery/firealarm/alarms_hidden alarms_hidden = TRUE /obj/machinery/firealarm/update_icon() cut_overlays() if(panel_open) set_light(0) return if(stat & BROKEN) icon_state = "firex" set_light(0) else if(stat & NOPOWER) icon_state = "firep" set_light(0) else if(!detecting) icon_state = "fire1" set_light(l_range = 4, l_power = 0.9, l_color = "#ff0000") else icon_state = "fire0" switch(seclevel) if("green") set_light(l_range = 2, l_power = 0.25, l_color = "#00ff00") if("yellow") set_light(l_range = 2, l_power = 0.25, l_color = "#ffff00") if("violet") set_light(l_range = 2, l_power = 0.25, l_color = "#9933ff") if("orange") set_light(l_range = 2, l_power = 0.25, l_color = "#ff9900") if("blue") set_light(l_range = 2, l_power = 0.25, l_color = "#1024A9") if("red") set_light(l_range = 4, l_power = 0.9, l_color = "#ff0000") if("delta") set_light(l_range = 4, l_power = 0.9, l_color = "#FF6633") add_overlay("overlay_[seclevel]") /obj/machinery/firealarm/fire_act(datum/gas_mixture/air, temperature, volume) if(detecting) if(temperature > T0C + 200) alarm() // added check of detector status here return /obj/machinery/firealarm/attack_ai(mob/user as mob) return attack_hand(user) /obj/machinery/firealarm/bullet_act() return alarm() /obj/machinery/firealarm/emp_act(severity) if(prob(50 / severity)) alarm(rand(30 / severity, 60 / severity)) ..() /obj/machinery/firealarm/attackby(obj/item/W as obj, mob/user as mob) add_fingerprint(user) if(alarm_deconstruction_screwdriver(user, W)) return if(alarm_deconstruction_wirecutters(user, W)) return if(panel_open) if(istype(W, /obj/item/device/multitool)) detecting = !(detecting) if(detecting) user.visible_message("\The [user] has reconnected [src]'s detecting unit!", "You have reconnected [src]'s detecting unit.") else user.visible_message("\The [user] has disconnected [src]'s detecting unit!", "You have disconnected [src]'s detecting unit.") return alarm() return /obj/machinery/firealarm/process()//Note: this processing was mostly phased out due to other code, and only runs when needed if(stat & (NOPOWER|BROKEN)) return if(timing) if(time > 0) time = time - ((world.timeofday - last_process) / 10) else alarm() time = 0 timing = 0 STOP_PROCESSING(SSobj, src) updateDialog() last_process = world.timeofday if(locate(/obj/fire) in src.loc) alarm() return /obj/machinery/firealarm/power_change() ..() spawn(rand(0,15)) update_icon() /obj/machinery/firealarm/attack_hand(mob/user as mob) if(user.stat || stat & (NOPOWER | BROKEN)) return user.set_machine(src) var/area/A = src.loc var/d1 var/d2 if(istype(user, /mob/living/carbon/human) || istype(user, /mob/living/silicon)) A = A.loc if(A.fire) d1 = text("Reset - Lockdown", src) else d1 = text("Alarm - Lockdown", src) if(timing) d2 = text("Stop Time Lock", src) else d2 = text("Initiate Time Lock", src) var/second = round(time) % 60 var/minute = (round(time) - second) / 60 var/dat = "Fire alarm [d1]\n
The current alert level is: [get_security_level()]

\nTimer System: [d2]
\nTime Left: [(minute ? "[minute]:" : null)][second] - - + +\n
" user << browse(dat, "window=firealarm") onclose(user, "firealarm") else A = A.loc if(A.fire) d1 = text("[]", src, stars("Reset - Lockdown")) else d1 = text("[]", src, stars("Alarm - Lockdown")) if(timing) d2 = text("[]", src, stars("Stop Time Lock")) else d2 = text("[]", src, stars("Initiate Time Lock")) var/second = round(time) % 60 var/minute = (round(time) - second) / 60 var/dat = "[stars("Fire alarm")] [d1]\n
The current alert level is: [stars(get_security_level())]

\nTimer System: [d2]
\nTime Left: [(minute ? text("[]:", minute) : null)][second] - - + +\n
" user << browse(dat, "window=firealarm") onclose(user, "firealarm") return /obj/machinery/firealarm/Topic(href, href_list) ..() if(usr.stat || stat & (BROKEN | NOPOWER)) return if((usr.contents.Find(src) || ((get_dist(src, usr) <= 1) && istype(src.loc, /turf))) || (istype(usr, /mob/living/silicon))) usr.set_machine(src) if(href_list["reset"]) reset() else if(href_list["alarm"]) alarm() else if(href_list["time"]) timing = text2num(href_list["time"]) last_process = world.timeofday START_PROCESSING(SSobj, src) else if(href_list["tp"]) var/tp = text2num(href_list["tp"]) time += tp time = min(max(round(time), 0), 120) updateUsrDialog() add_fingerprint(usr) else usr << browse(null, "window=firealarm") return return /obj/machinery/firealarm/proc/reset() if(!(working)) return var/area/area = get_area(src) for(var/obj/machinery/firealarm/FA in area) fire_alarm.clearAlarm(src.loc, FA) update_icon() return /obj/machinery/firealarm/proc/alarm(var/duration = 0) if(!(working)) return var/area/area = get_area(src) for(var/obj/machinery/firealarm/FA in area) fire_alarm.triggerAlarm(loc, FA, duration, hidden = alarms_hidden) update_icon() playsound(src.loc, 'sound/machines/airalarm.ogg', 25, 0, 4) return /obj/machinery/firealarm/proc/set_security_level(var/newlevel) if(seclevel != newlevel) seclevel = newlevel update_icon() /obj/machinery/firealarm/Initialize() . = ..() if(z in using_map.contact_levels) set_security_level(security_level? get_security_level() : "green") /* FIRE ALARM CIRCUIT Just a object used in constructing fire alarms /obj/item/weapon/firealarm_electronics name = "fire alarm electronics" icon = 'icons/obj/doors/door_assembly.dmi' icon_state = "door_electronics" desc = "A circuit. It has a label on it, it says \"Can handle heat levels up to 40 degrees celsius!\"" w_class = ITEMSIZE_SMALL matter = list(DEFAULT_WALL_MATERIAL = 50, "glass" = 50) */ /obj/machinery/partyalarm name = "\improper PARTY BUTTON" desc = "Cuban Pete is in the house!" icon = 'icons/obj/monitors.dmi' icon_state = "fire0" var/detecting = 1.0 var/working = 1.0 var/time = 10.0 var/timing = 0.0 var/lockdownbyai = 0 anchored = 1.0 use_power = 1 idle_power_usage = 2 active_power_usage = 6 /obj/machinery/partyalarm/attack_hand(mob/user as mob) if(user.stat || stat & (NOPOWER|BROKEN)) return user.machine = src var/area/A = get_area(src) ASSERT(isarea(A)) var/d1 var/d2 if(istype(user, /mob/living/carbon/human) || istype(user, /mob/living/silicon/ai)) if(A.party) d1 = text("No Party :(", src) else d1 = text("PARTY!!!", src) if(timing) d2 = text("Stop Time Lock", src) else d2 = text("Initiate Time Lock", src) var/second = time % 60 var/minute = (time - second) / 60 var/dat = text("Party Button []\n
\nTimer System: []
\nTime Left: [][] - - + +\n
", d1, d2, (minute ? text("[]:", minute) : null), second, src, src, src, src) user << browse(dat, "window=partyalarm") onclose(user, "partyalarm") else if(A.fire) d1 = text("[]", src, stars("No Party :(")) else d1 = text("[]", src, stars("PARTY!!!")) if(timing) d2 = text("[]", src, stars("Stop Time Lock")) else d2 = text("[]", src, stars("Initiate Time Lock")) var/second = time % 60 var/minute = (time - second) / 60 var/dat = text("[] []\n
\nTimer System: []
\nTime Left: [][] - - + +\n
", stars("Party Button"), d1, d2, (minute ? text("[]:", minute) : null), second, src, src, src, src) user << browse(dat, "window=partyalarm") onclose(user, "partyalarm") return /obj/machinery/partyalarm/proc/reset() if(!(working)) return var/area/A = get_area(src) ASSERT(isarea(A)) A.partyreset() return /obj/machinery/partyalarm/proc/alarm() if(!(working)) return var/area/A = get_area(src) ASSERT(isarea(A)) A.partyalert() return /obj/machinery/partyalarm/Topic(href, href_list) ..() if(usr.stat || stat & (BROKEN|NOPOWER)) return if((usr.contents.Find(src) || ((get_dist(src, usr) <= 1) && istype(loc, /turf))) || (istype(usr, /mob/living/silicon/ai))) usr.machine = src if(href_list["reset"]) reset() else if(href_list["alarm"]) alarm() else if(href_list["time"]) timing = text2num(href_list["time"]) else if(href_list["tp"]) var/tp = text2num(href_list["tp"]) time += tp time = min(max(round(time), 0), 120) updateUsrDialog() add_fingerprint(usr) else usr << browse(null, "window=partyalarm") return return