/datum/wires/alarm
|
|
holder_type = /obj/machinery/alarm
|
|
wire_count = 5
|
|
|
|
var/const/AALARM_WIRE_IDSCAN = 1
|
|
var/const/AALARM_WIRE_POWER = 2
|
|
var/const/AALARM_WIRE_SYPHON = 4
|
|
var/const/AALARM_WIRE_AI_CONTROL = 8
|
|
var/const/AALARM_WIRE_AALARM = 16
|
|
|
|
|
|
/datum/wires/alarm/CanUse(var/mob/living/L)
|
|
var/obj/machinery/alarm/A = holder
|
|
if(A.wiresexposed)
|
|
return 1
|
|
return 0
|
|
|
|
/datum/wires/alarm/GetInteractWindow()
|
|
var/obj/machinery/alarm/A = holder
|
|
. += ..()
|
|
. += text("<br>\n[(A.locked ? "The Air Alarm is locked." : "The Air Alarm is unlocked.")]<br>\n[((A.shorted || (A.stat & (NOPOWER|BROKEN))) ? "The Air Alarm is offline." : "The Air Alarm is working properly!")]<br>\n[(A.aidisabled ? "The 'AI control allowed' light is off." : "The 'AI control allowed' light is on.")]")
|
|
|
|
/datum/wires/alarm/UpdateCut(var/index, var/mended)
|
|
var/obj/machinery/alarm/A = holder
|
|
switch(index)
|
|
if(AALARM_WIRE_IDSCAN)
|
|
if(!mended)
|
|
A.locked = 1
|
|
//world << "Idscan wire cut"
|
|
|
|
if(AALARM_WIRE_POWER)
|
|
A.shock(usr, 50)
|
|
A.shorted = !mended
|
|
A.update_icon()
|
|
//world << "Power wire cut"
|
|
|
|
if (AALARM_WIRE_AI_CONTROL)
|
|
if (A.aidisabled == !mended)
|
|
A.aidisabled = mended
|
|
//world << "AI Control Wire Cut"
|
|
|
|
if(AALARM_WIRE_SYPHON)
|
|
if(!mended)
|
|
A.mode = 3 // AALARM_MODE_PANIC
|
|
A.apply_mode()
|
|
//world << "Syphon Wire Cut"
|
|
|
|
if(AALARM_WIRE_AALARM)
|
|
if (A.alarm_area.atmosalert(2))
|
|
A.post_alert(2)
|
|
A.update_icon()
|
|
|
|
/datum/wires/alarm/UpdatePulsed(var/index)
|
|
var/obj/machinery/alarm/A = holder
|
|
switch(index)
|
|
if(AALARM_WIRE_IDSCAN)
|
|
A.locked = !A.locked
|
|
// world << "Idscan wire pulsed"
|
|
|
|
if (AALARM_WIRE_POWER)
|
|
// world << "Power wire pulsed"
|
|
if(A.shorted == 0)
|
|
A.shorted = 1
|
|
A.update_icon()
|
|
|
|
spawn(12000)
|
|
if(A.shorted == 1)
|
|
A.shorted = 0
|
|
A.update_icon()
|
|
|
|
|
|
if (AALARM_WIRE_AI_CONTROL)
|
|
// world << "AI Control wire pulsed"
|
|
if (A.aidisabled == 0)
|
|
A.aidisabled = 1
|
|
A.updateDialog()
|
|
spawn(100)
|
|
if (A.aidisabled == 1)
|
|
A.aidisabled = 0
|
|
|
|
if(AALARM_WIRE_SYPHON)
|
|
// world << "Syphon wire pulsed"
|
|
if(A.mode == 1) // AALARM_MODE_SCRUB
|
|
A.mode = 3 // AALARM_MODE_PANIC
|
|
else
|
|
A.mode = 1 // AALARM_MODE_SCRUB
|
|
A.apply_mode()
|
|
|
|
if(AALARM_WIRE_AALARM)
|
|
// world << "Aalarm wire pulsed"
|
|
if (A.alarm_area.atmosalert(0))
|
|
A.post_alert(0)
|
|
A.update_icon()
|