/datum/wires/grid_checker
holder_type = /obj/machinery/power/grid_checker
wire_count = 8
var/const/GRID_CHECKER_WIRE_REBOOT = 1 // This wire causes the grid-check to end, if pulsed.
var/const/GRID_CHECKER_WIRE_LOCKOUT = 2 // If cut or pulsed, locks the user out for half a minute.
var/const/GRID_CHECKER_WIRE_ALLOW_MANUAL_1 = 4 // Needs to be cut for REBOOT to be possible.
var/const/GRID_CHECKER_WIRE_ALLOW_MANUAL_2 = 8 // Needs to be cut for REBOOT to be possible.
var/const/GRID_CHECKER_WIRE_ALLOW_MANUAL_3 = 16 // Needs to be cut for REBOOT to be possible.
var/const/GRID_CHECKER_WIRE_SHOCK = 32 // Shocks the user if not wearing gloves.
var/const/GRID_CHECKER_WIRE_NOTHING_1 = 64 // Does nothing, but makes it a bit harder.
var/const/GRID_CHECKER_WIRE_NOTHING_2 = 128 // Does nothing, but makes it a bit harder.
/datum/wires/grid_checker/CanUse(var/mob/living/L)
var/obj/machinery/power/grid_checker/G = holder
if(G.opened)
return TRUE
return FALSE
/datum/wires/grid_checker/GetInteractWindow()
var/obj/machinery/power/grid_checker/G = holder
. += ..()
. += show_hint(0x1, G.power_failing, "The green light is off.", "The green light is on.")
. += show_hint(0x2, G.wire_locked_out, "The red light is on.", "The red light is off.")
. += show_hint(0x4, G.wire_allow_manual_1 && G.wire_allow_manual_2 && G.wire_allow_manual_3, "The blue light is on.", "The blue light is off.")
/datum/wires/grid_checker/UpdateCut(var/index, var/mended)
var/obj/machinery/power/grid_checker/G = holder
switch(index)
if(GRID_CHECKER_WIRE_LOCKOUT)
G.wire_locked_out = !mended
if(GRID_CHECKER_WIRE_ALLOW_MANUAL_1)
G.wire_allow_manual_1 = !mended
if(GRID_CHECKER_WIRE_ALLOW_MANUAL_2)
G.wire_allow_manual_2 = !mended
if(GRID_CHECKER_WIRE_ALLOW_MANUAL_3)
G.wire_allow_manual_3 = !mended
if(GRID_CHECKER_WIRE_SHOCK)
if(G.wire_locked_out)
return
G.shock(usr, 70)
/datum/wires/grid_checker/UpdatePulsed(var/index)
var/obj/machinery/power/grid_checker/G = holder
switch(index)
if(GRID_CHECKER_WIRE_REBOOT)
if(G.wire_locked_out)
return
if(G.power_failing && G.wire_allow_manual_1 && G.wire_allow_manual_2 && G.wire_allow_manual_3)
G.end_power_failure(TRUE)
if(GRID_CHECKER_WIRE_LOCKOUT)
if(G.wire_locked_out)
return
G.wire_locked_out = TRUE
spawn(30 SECONDS)
G.wire_locked_out = FALSE
if(GRID_CHECKER_WIRE_SHOCK)
if(G.wire_locked_out)
return
G.shock(usr, 70)