Files
CHOMPStation2/code/ATMOSPHERICS/components/binary_devices/dp_vent_pump.dm
rastaf.zero@gmail.com 2530b5b995 Air alarms improved. New functions are:
- mass control all air machines in area (5 modes)
 - adjustable alarm thresholds
 - air alarm in server room now is preset to treat temperature 80 K as okay.
EMP now affects bots internal cameras.
Fixed problem with AI clicking on mulebot.
Some fixes for welding with unlit welder, mostly cosmetic.
Airlock controller (as in EVA) now react to commands faster.
Access controller (was in engineering and virology in past) was speeded up too. One is installed into Incinerator to demonstrate that now it isn't fucking slow.
Airlock in toxin mixing room now have pump, so airlock can work properly.
Added some intercoms to medbay lobby.
Doors now won't lag due do mapmakers mistakes.


git-svn-id: http://tgstation13.googlecode.com/svn/trunk@1187 316c924e-a436-60f5-8080-3fe189b3f50e
2011-03-14 19:21:02 +00:00

199 lines
5.0 KiB
Plaintext

/obj/machinery/atmospherics/binary/dp_vent_pump
icon = 'dp_vent_pump.dmi'
icon_state = "off"
//node2 is output port
//node1 is input port
name = "Dual Port Air Vent"
desc = "Has a valve and pump attached to it. There are two ports."
level = 1
high_volume
name = "Large Dual Port Air Vent"
New()
..()
air1.volume = 1000
air2.volume = 1000
var/on = 0
var/pump_direction = 1 //0 = siphoning, 1 = releasing
var/external_pressure_bound = ONE_ATMOSPHERE
var/input_pressure_min = 0
var/output_pressure_max = 0
var/pressure_checks = 1
//1: Do not pass external_pressure_bound
//2: Do not pass input_pressure_min
//4: Do not pass output_pressure_max
update_icon()
if(on)
if(pump_direction)
icon_state = "[level == 1 && istype(loc, /turf/simulated) ? "h" : "" ]out"
else
icon_state = "[level == 1 && istype(loc, /turf/simulated) ? "h" : "" ]in"
else
icon_state = "[level == 1 && istype(loc, /turf/simulated) ? "h" : "" ]off"
on = 0
return
hide(var/i) //to make the little pipe section invisible, the icon changes.
if(on)
if(pump_direction)
icon_state = "[i == 1 && istype(loc, /turf/simulated) ? "h" : "" ]out"
else
icon_state = "[i == 1 && istype(loc, /turf/simulated) ? "h" : "" ]in"
else
icon_state = "[i == 1 && istype(loc, /turf/simulated) ? "h" : "" ]off"
on = 0
return
process()
..()
if(!on)
return 0
var/datum/gas_mixture/environment = loc.return_air()
var/environment_pressure = environment.return_pressure()
if(pump_direction) //input -> external
var/pressure_delta = 10000
if(pressure_checks&1)
pressure_delta = min(pressure_delta, (external_pressure_bound - environment_pressure))
if(pressure_checks&2)
pressure_delta = min(pressure_delta, (air1.return_pressure() - input_pressure_min))
if(pressure_delta > 0)
if(air1.temperature > 0)
var/transfer_moles = pressure_delta*environment.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
loc.assume_air(removed)
if(network1)
network1.update = 1
else //external -> output
var/pressure_delta = 10000
if(pressure_checks&1)
pressure_delta = min(pressure_delta, (environment_pressure - external_pressure_bound))
if(pressure_checks&4)
pressure_delta = min(pressure_delta, (output_pressure_max - air2.return_pressure()))
if(pressure_delta > 0)
if(environment.temperature > 0)
var/transfer_moles = pressure_delta*air2.volume/(environment.temperature * R_IDEAL_GAS_EQUATION)
var/datum/gas_mixture/removed = loc.remove_air(transfer_moles)
air2.merge(removed)
if(network2)
network2.update = 1
return 1
//Radio remote control
proc
set_frequency(new_frequency)
radio_controller.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA)
broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "ADVP",
"power" = on,
"direction" = pump_direction?("release"):("siphon"),
"checks" = pressure_checks,
"input" = input_pressure_min,
"output" = output_pressure_max,
"external" = external_pressure_bound,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
initialize()
..()
if(frequency)
set_frequency(frequency)
receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
if("power" in signal.data)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
on = !on
if("set_direction" in signal.data)
pump_direction = text2num(signal.data["set_direction"])
if("checks" in signal.data)
pressure_checks = text2num(signal.data["checks"])
if("purge" in signal.data)
pressure_checks &= ~1
pump_direction = 0
if("stabalize" in signal.data)
pressure_checks |= 1
pump_direction = 1
if("set_input_pressure" in signal.data)
input_pressure_min = between(
0,
text2num(signal.data["set_input_pressure"]),
ONE_ATMOSPHERE*50
)
if("set_output_pressure" in signal.data)
output_pressure_max = between(
0,
text2num(signal.data["set_output_pressure"]),
ONE_ATMOSPHERE*50
)
if("set_external_pressure" in signal.data)
external_pressure_bound = between(
0,
text2num(signal.data["set_external_pressure"]),
ONE_ATMOSPHERE*50
)
if("status" in signal.data)
spawn(2)
broadcast_status()
return //do not update_icon
//if(signal.data["tag"])
spawn(2)
broadcast_status()
update_icon()