Files
CHOMPStation2/code/ATMOSPHERICS/components/binary_devices/volume_pump.dm
rastaf.zero@gmail.com 2530b5b995 Air alarms improved. New functions are:
- mass control all air machines in area (5 modes)
 - adjustable alarm thresholds
 - air alarm in server room now is preset to treat temperature 80 K as okay.
EMP now affects bots internal cameras.
Fixed problem with AI clicking on mulebot.
Some fixes for welding with unlit welder, mostly cosmetic.
Airlock controller (as in EVA) now react to commands faster.
Access controller (was in engineering and virology in past) was speeded up too. One is installed into Incinerator to demonstrate that now it isn't fucking slow.
Airlock in toxin mixing room now have pump, so airlock can work properly.
Added some intercoms to medbay lobby.
Doors now won't lag due do mapmakers mistakes.


git-svn-id: http://tgstation13.googlecode.com/svn/trunk@1187 316c924e-a436-60f5-8080-3fe189b3f50e
2011-03-14 19:21:02 +00:00

117 lines
2.5 KiB
Plaintext

/*
Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
node1, air1, network1 correspond to input
node2, air2, network2 correspond to output
Thus, the two variables affect pump operation are set in New():
air1.volume
This is the volume of gas available to the pump that may be transfered to the output
air2.volume
Higher quantities of this cause more air to be perfected later
but overall network volume is also increased as this increases...
*/
obj/machinery/atmospherics/binary/volume_pump
icon = 'volume_pump.dmi'
icon_state = "intact_off"
name = "Gas pump"
desc = "A pump"
var/on = 0
var/transfer_rate = 200
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
update_icon()
if(node1&&node2)
icon_state = "intact_[on?("on"):("off")]"
else
if(node1)
icon_state = "exposed_1_off"
else if(node2)
icon_state = "exposed_2_off"
else
icon_state = "exposed_3_off"
on = 0
return
process()
..()
if(!on)
return 0
var/transfer_ratio = max(1, transfer_rate/air1.volume)
var/datum/gas_mixture/removed = air1.remove_ratio(transfer_ratio)
air2.merge(removed)
if(network1)
network1.update = 1
if(network2)
network2.update = 1
return 1
proc
set_frequency(new_frequency)
radio_controller.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = radio_controller.add_object(src, frequency)
broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "APV",
"power" = on,
"transfer_rate" = transfer_rate,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal)
return 1
initialize()
..()
set_frequency(frequency)
receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
if("power" in signal.data)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
on = !on
if("set_transfer_rate" in signal.data)
transfer_rate = between(
0,
text2num(signal.data["set_transfer_rate"]),
air1.volume
)
if("status" in signal.data)
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()