//Handles the control of airlocks
|
|
|
|
#define STATE_IDLE 0
|
|
#define STATE_PREPARE 1
|
|
#define STATE_DEPRESSURIZE 2
|
|
#define STATE_PRESSURIZE 3
|
|
|
|
#define TARGET_NONE 0
|
|
#define TARGET_INOPEN -1
|
|
#define TARGET_OUTOPEN -2
|
|
|
|
|
|
/datum/computer/file/embedded_program/airlock
|
|
var/tag_exterior_door
|
|
var/tag_interior_door
|
|
var/tag_airpump
|
|
var/tag_chamber_sensor
|
|
var/tag_exterior_sensor
|
|
var/tag_interior_sensor
|
|
var/tag_mech_sensor
|
|
|
|
var/state = STATE_IDLE
|
|
var/target_state = TARGET_NONE
|
|
|
|
/datum/computer/file/embedded_program/airlock/New(var/obj/machinery/embedded_controller/M)
|
|
..(M)
|
|
|
|
memory["chamber_sensor_pressure"] = ONE_ATMOSPHERE
|
|
memory["external_sensor_pressure"] = 0 //assume vacuum for simple airlock controller
|
|
memory["internal_sensor_pressure"] = ONE_ATMOSPHERE
|
|
memory["exterior_status"] = list(state = "closed", lock = "locked") //assume closed and locked in case the doors dont report in
|
|
memory["interior_status"] = list(state = "closed", lock = "locked")
|
|
memory["pump_status"] = "unknown"
|
|
memory["target_pressure"] = ONE_ATMOSPHERE
|
|
memory["purge"] = 0
|
|
memory["secure"] = 0
|
|
|
|
if (istype(M, /obj/machinery/embedded_controller/radio/airlock)) //if our controller is an airlock controller than we can auto-init our tags
|
|
var/obj/machinery/embedded_controller/radio/airlock/controller = M
|
|
tag_exterior_door = controller.tag_exterior_door? controller.tag_exterior_door : "[id_tag]_outer"
|
|
tag_interior_door = controller.tag_interior_door? controller.tag_interior_door : "[id_tag]_inner"
|
|
tag_airpump = controller.tag_airpump? controller.tag_airpump : "[id_tag]_pump"
|
|
tag_chamber_sensor = controller.tag_chamber_sensor? controller.tag_chamber_sensor : "[id_tag]_sensor"
|
|
tag_exterior_sensor = controller.tag_exterior_sensor
|
|
tag_interior_sensor = controller.tag_interior_sensor
|
|
tag_mech_sensor = controller.tag_mech_sensor? controller.tag_mech_sensor : "[id_tag]_mech"
|
|
memory["secure"] = controller.tag_secure
|
|
|
|
spawn(10)
|
|
signalDoor(tag_exterior_door, "update") //signals connected doors to update their status
|
|
signalDoor(tag_interior_door, "update")
|
|
|
|
/datum/computer/file/embedded_program/airlock/receive_signal(datum/signal/signal, receive_method, receive_param)
|
|
var/receive_tag = signal.data["tag"]
|
|
if(!receive_tag) return
|
|
|
|
if(receive_tag==tag_chamber_sensor)
|
|
if(signal.data["pressure"])
|
|
memory["chamber_sensor_pressure"] = text2num(signal.data["pressure"])
|
|
|
|
else if(receive_tag==tag_exterior_sensor)
|
|
memory["external_sensor_pressure"] = text2num(signal.data["pressure"])
|
|
|
|
else if(receive_tag==tag_interior_sensor)
|
|
memory["internal_sensor_pressure"] = text2num(signal.data["pressure"])
|
|
|
|
else if(receive_tag==tag_exterior_door)
|
|
memory["exterior_status"]["state"] = signal.data["door_status"]
|
|
memory["exterior_status"]["lock"] = signal.data["lock_status"]
|
|
|
|
else if(receive_tag==tag_interior_door)
|
|
memory["interior_status"]["state"] = signal.data["door_status"]
|
|
memory["interior_status"]["lock"] = signal.data["lock_status"]
|
|
|
|
else if(receive_tag==tag_airpump)
|
|
if(signal.data["power"])
|
|
memory["pump_status"] = signal.data["direction"]
|
|
else
|
|
memory["pump_status"] = "off"
|
|
|
|
else if(receive_tag==id_tag)
|
|
if(istype(master, /obj/machinery/embedded_controller/radio/airlock/access_controller))
|
|
switch(signal.data["command"])
|
|
if("cycle_exterior")
|
|
receive_user_command("cycle_ext_door")
|
|
if("cycle_interior")
|
|
receive_user_command("cycle_int_door")
|
|
if("cycle")
|
|
if(memory["interior_status"]["state"] == "open") //handle backwards compatibility
|
|
receive_user_command("cycle_ext")
|
|
else
|
|
receive_user_command("cycle_int")
|
|
else
|
|
switch(signal.data["command"])
|
|
if("cycle_exterior")
|
|
receive_user_command("cycle_ext")
|
|
if("cycle_interior")
|
|
receive_user_command("cycle_int")
|
|
if("cycle")
|
|
if(memory["interior_status"]["state"] == "open") //handle backwards compatibility
|
|
receive_user_command("cycle_ext")
|
|
else
|
|
receive_user_command("cycle_int")
|
|
|
|
|
|
/datum/computer/file/embedded_program/airlock/receive_user_command(command)
|
|
var/shutdown_pump = 0
|
|
switch(command)
|
|
if("cycle_ext")
|
|
begin_cycle_out()
|
|
|
|
if("cycle_int")
|
|
begin_cycle_in()
|
|
|
|
if("cycle_ext_door")
|
|
cycleDoors(TARGET_OUTOPEN)
|
|
|
|
if("cycle_int_door")
|
|
cycleDoors(TARGET_INOPEN)
|
|
|
|
if("abort")
|
|
stop_cycling()
|
|
/*
|
|
//dont do this. If the airlock can't get enough air to pressurize the person inside is stuck
|
|
state = STATE_PRESSURIZE
|
|
target_state = TARGET_NONE
|
|
memory["target_pressure"] = ONE_ATMOSPHERE
|
|
signalPump(tag_airpump, 1, 1, memory["target_pressure"])
|
|
process()
|
|
*/
|
|
|
|
if("force_ext")
|
|
toggleDoor(memory["exterior_status"], tag_exterior_door, memory["secure"], "toggle")
|
|
|
|
if("force_int")
|
|
toggleDoor(memory["interior_status"], tag_interior_door, memory["secure"], "toggle")
|
|
|
|
if("purge")
|
|
memory["purge"] = !memory["purge"]
|
|
if(memory["purge"])
|
|
toggleDoor(memory["exterior_status"], tag_exterior_door, 1, "close")
|
|
toggleDoor(memory["interior_status"], tag_interior_door, 1, "close")
|
|
state = STATE_DEPRESSURIZE
|
|
target_state = TARGET_NONE
|
|
signalPump(tag_airpump, 1, 0, 0)
|
|
|
|
if("secure")
|
|
memory["secure"] = !memory["secure"]
|
|
if(memory["secure"])
|
|
signalDoor(tag_interior_door, "lock")
|
|
signalDoor(tag_exterior_door, "lock")
|
|
else
|
|
signalDoor(tag_interior_door, "unlock")
|
|
signalDoor(tag_exterior_door, "unlock")
|
|
|
|
if(shutdown_pump)
|
|
signalPump(tag_airpump, 0) //send a signal to stop pressurizing
|
|
|
|
|
|
/datum/computer/file/embedded_program/airlock/process()
|
|
if(!state) //Idle
|
|
if(target_state)
|
|
switch(target_state)
|
|
if(TARGET_INOPEN)
|
|
memory["target_pressure"] = memory["internal_sensor_pressure"]
|
|
if(TARGET_OUTOPEN)
|
|
memory["target_pressure"] = memory["external_sensor_pressure"]
|
|
|
|
//lock down the airlock before activating pumps
|
|
close_doors()
|
|
|
|
state = STATE_PREPARE
|
|
else
|
|
//make sure to return to a sane idle state
|
|
if(memory["pump_status"] != "off") //send a signal to stop pumping
|
|
signalPump(tag_airpump, 0)
|
|
|
|
if ((state == STATE_PRESSURIZE || state == STATE_DEPRESSURIZE) && !check_doors_secured())
|
|
//the airlock will not allow itself to continue to cycle when any of the doors are forced open.
|
|
stop_cycling()
|
|
|
|
switch(state)
|
|
if(STATE_PREPARE)
|
|
if (check_doors_secured())
|
|
var/chamber_pressure = memory["chamber_sensor_pressure"]
|
|
var/target_pressure = memory["target_pressure"]
|
|
|
|
if(memory["purge"])
|
|
target_pressure = 0
|
|
|
|
if(memory["purge"])
|
|
target_pressure = 0
|
|
|
|
if(chamber_pressure <= target_pressure)
|
|
state = STATE_PRESSURIZE
|
|
signalPump(tag_airpump, 1, 1, target_pressure) //send a signal to start pressurizing
|
|
|
|
else if(chamber_pressure > target_pressure)
|
|
state = STATE_DEPRESSURIZE
|
|
signalPump(tag_airpump, 1, 0, target_pressure) //send a signal to start depressurizing
|
|
|
|
//Check for vacuum - this is set after the pumps so the pumps are aiming for 0
|
|
if(!memory["target_pressure"])
|
|
memory["target_pressure"] = ONE_ATMOSPHERE * 0.05
|
|
|
|
if(STATE_PRESSURIZE)
|
|
if(memory["chamber_sensor_pressure"] >= memory["target_pressure"] * 0.95)
|
|
cycleDoors(target_state)
|
|
|
|
state = STATE_IDLE
|
|
target_state = TARGET_NONE
|
|
|
|
if(memory["pump_status"] != "off")
|
|
signalPump(tag_airpump, 0) //send a signal to stop pumping
|
|
|
|
|
|
if(STATE_DEPRESSURIZE)
|
|
if(memory["purge"])
|
|
if(memory["chamber_sensor_pressure"] <= ONE_ATMOSPHERE * 0.05)
|
|
state = STATE_PRESSURIZE
|
|
signalPump(tag_airpump, 1, 1, memory["target_pressure"])
|
|
|
|
|
|
else if(memory["chamber_sensor_pressure"] <= memory["target_pressure"] * 1.05)
|
|
cycleDoors(target_state)
|
|
|
|
state = STATE_IDLE
|
|
target_state = TARGET_NONE
|
|
|
|
//send a signal to stop pumping
|
|
if(memory["pump_status"] != "off")
|
|
signalPump(tag_airpump, 0)
|
|
|
|
|
|
memory["processing"] = state != target_state
|
|
|
|
return 1
|
|
|
|
//these are here so that other types don't have to make so many assuptions about our implementation
|
|
|
|
/datum/computer/file/embedded_program/airlock/proc/begin_cycle_in()
|
|
state = STATE_IDLE
|
|
target_state = TARGET_INOPEN
|
|
|
|
/datum/computer/file/embedded_program/airlock/proc/begin_cycle_out()
|
|
state = STATE_IDLE
|
|
target_state = TARGET_OUTOPEN
|
|
|
|
/datum/computer/file/embedded_program/airlock/proc/close_doors()
|
|
toggleDoor(memory["interior_status"], tag_interior_door, 1, "close")
|
|
toggleDoor(memory["exterior_status"], tag_exterior_door, 1, "close")
|
|
|
|
/datum/computer/file/embedded_program/airlock/proc/stop_cycling()
|
|
state = STATE_IDLE
|
|
target_state = TARGET_NONE
|
|
|
|
/datum/computer/file/embedded_program/airlock/proc/done_cycling()
|
|
return (state == STATE_IDLE && target_state == TARGET_NONE)
|
|
|
|
//are the doors closed and locked?
|
|
/datum/computer/file/embedded_program/airlock/proc/check_exterior_door_secured()
|
|
return (memory["exterior_status"]["state"] == "closed" && memory["exterior_status"]["lock"] == "locked")
|
|
|
|
/datum/computer/file/embedded_program/airlock/proc/check_interior_door_secured()
|
|
return (memory["interior_status"]["state"] == "closed" && memory["interior_status"]["lock"] == "locked")
|
|
|
|
/datum/computer/file/embedded_program/airlock/proc/check_doors_secured()
|
|
var/ext_closed = check_exterior_door_secured()
|
|
var/int_closed = check_interior_door_secured()
|
|
return (ext_closed && int_closed)
|
|
|
|
/datum/computer/file/embedded_program/airlock/proc/signalDoor(var/tag, var/command)
|
|
var/datum/signal/signal = new
|
|
signal.data["tag"] = tag
|
|
signal.data["command"] = command
|
|
post_signal(signal, RADIO_AIRLOCK)
|
|
|
|
/datum/computer/file/embedded_program/airlock/proc/signalPump(var/tag, var/power, var/direction, var/pressure)
|
|
var/datum/signal/signal = new
|
|
signal.data = list(
|
|
"tag" = tag,
|
|
"sigtype" = "command",
|
|
"power" = power,
|
|
"direction" = direction,
|
|
"set_external_pressure" = pressure
|
|
)
|
|
post_signal(signal)
|
|
|
|
//this is called to set the appropriate door state at the end of a cycling process, or for the exterior buttons
|
|
/datum/computer/file/embedded_program/airlock/proc/cycleDoors(var/target)
|
|
switch(target)
|
|
if(TARGET_OUTOPEN)
|
|
toggleDoor(memory["interior_status"], tag_interior_door, memory["secure"], "close")
|
|
toggleDoor(memory["exterior_status"], tag_exterior_door, memory["secure"], "open")
|
|
|
|
if(TARGET_INOPEN)
|
|
toggleDoor(memory["exterior_status"], tag_exterior_door, memory["secure"], "close")
|
|
toggleDoor(memory["interior_status"], tag_interior_door, memory["secure"], "open")
|
|
if(TARGET_NONE)
|
|
var/command = "unlock"
|
|
if(memory["secure"])
|
|
command = "lock"
|
|
signalDoor(tag_exterior_door, command)
|
|
signalDoor(tag_interior_door, command)
|
|
|
|
datum/computer/file/embedded_program/airlock/proc/signal_mech_sensor(var/command)
|
|
var/datum/signal/signal = new
|
|
signal.data["tag"] = tag_mech_sensor
|
|
signal.data["command"] = command
|
|
post_signal(signal)
|
|
|
|
/datum/computer/file/embedded_program/airlock/proc/enable_mech_regulation()
|
|
signal_mech_sensor("enable")
|
|
|
|
/datum/computer/file/embedded_program/airlock/proc/disable_mech_regulation()
|
|
signal_mech_sensor("disable")
|
|
|
|
/*----------------------------------------------------------
|
|
toggleDoor()
|
|
|
|
Sends a radio command to a door to either open or close. If
|
|
the command is 'toggle' the door will be sent a command that
|
|
reverses it's current state.
|
|
Can also toggle whether the door bolts are locked or not,
|
|
depending on the state of the 'secure' flag.
|
|
Only sends a command if it is needed, i.e. if the door is
|
|
already open, passing an open command to this proc will not
|
|
send an additional command to open the door again.
|
|
----------------------------------------------------------*/
|
|
/datum/computer/file/embedded_program/airlock/proc/toggleDoor(var/list/doorStatus, var/doorTag, var/secure, var/command)
|
|
var/doorCommand = null
|
|
|
|
if(command == "toggle")
|
|
if(doorStatus["state"] == "open")
|
|
command = "close"
|
|
else if(doorStatus["state"] == "closed")
|
|
command = "open"
|
|
|
|
switch(command)
|
|
if("close")
|
|
if(secure)
|
|
if(doorStatus["state"] == "open")
|
|
doorCommand = "secure_close"
|
|
else if(doorStatus["lock"] == "unlocked")
|
|
doorCommand = "lock"
|
|
else
|
|
if(doorStatus["state"] == "open")
|
|
if(doorStatus["lock"] == "locked")
|
|
signalDoor(doorTag, "unlock")
|
|
doorCommand = "close"
|
|
else if(doorStatus["lock"] == "locked")
|
|
doorCommand = "unlock"
|
|
|
|
if("open")
|
|
if(secure)
|
|
if(doorStatus["state"] == "closed")
|
|
doorCommand = "secure_open"
|
|
else if(doorStatus["lock"] == "unlocked")
|
|
doorCommand = "lock"
|
|
else
|
|
if(doorStatus["state"] == "closed")
|
|
if(doorStatus["lock"] == "locked")
|
|
signalDoor(doorTag,"unlock")
|
|
doorCommand = "open"
|
|
else if(doorStatus["lock"] == "locked")
|
|
doorCommand = "unlock"
|
|
|
|
if(doorCommand)
|
|
signalDoor(doorTag, doorCommand)
|
|
|
|
|
|
#undef STATE_IDLE
|
|
#undef STATE_DEPRESSURIZE
|
|
#undef STATE_PRESSURIZE
|
|
|
|
#undef TARGET_NONE
|
|
#undef TARGET_INOPEN
|
|
#undef TARGET_OUTOPEN |