Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
|
|
|
|
node1, air1, network1 correspond to input
|
|
node2, air2, network2 correspond to output
|
|
|
|
Thus, the two variables affect pump operation are set in New():
|
|
air1.volume
|
|
This is the volume of gas available to the pump that may be transfered to the output
|
|
air2.volume
|
|
Higher quantities of this cause more air to be perfected later
|
|
but overall network volume is also increased as this increases...
|
|
*/
|
|
|
|
/obj/machinery/atmospherics/binary/pump
|
|
icon = 'icons/atmos/pump.dmi'
|
|
icon_state = "map"
|
|
level = 1
|
|
|
|
name = "Gas pump"
|
|
desc = "A pump"
|
|
|
|
var/on = 0
|
|
var/target_pressure = ONE_ATMOSPHERE
|
|
|
|
//var/max_volume_transfer = 10000
|
|
|
|
use_power = 1
|
|
idle_power_usage = 150 //internal circuitry, friction losses and stuff
|
|
active_power_usage = 7500 //This also doubles as a measure of how powerful the pump is, in Watts. 7500 W ~ 10 HP
|
|
var/last_power_draw = 0 //for UI
|
|
var/max_pressure_setting = 9000 //kPa
|
|
|
|
var/frequency = 0
|
|
var/id = null
|
|
var/datum/radio_frequency/radio_connection
|
|
|
|
/obj/machinery/atmospherics/binary/pump/highcap
|
|
name = "High capacity gas pump"
|
|
desc = "A high capacity pump"
|
|
|
|
target_pressure = 15000000 //15 GPa? Really?
|
|
active_power_usage = 112500 //150 Horsepower
|
|
|
|
/obj/machinery/atmospherics/binary/pump/on
|
|
on = 1
|
|
|
|
/obj/machinery/atmospherics/binary/pump/update_icon()
|
|
if(!powered())
|
|
icon_state = "off"
|
|
else
|
|
icon_state = "[on ? "on" : "off"]"
|
|
|
|
/obj/machinery/atmospherics/binary/pump/update_underlays()
|
|
if(..())
|
|
underlays.Cut()
|
|
var/turf/T = get_turf(src)
|
|
if(!istype(T))
|
|
return
|
|
add_underlay(T, node1, turn(dir, -180))
|
|
add_underlay(T, node2, dir)
|
|
|
|
/obj/machinery/atmospherics/binary/pump/hide(var/i)
|
|
update_underlays()
|
|
|
|
/obj/machinery/atmospherics/binary/pump/process()
|
|
// ..()
|
|
if(stat & (NOPOWER|BROKEN))
|
|
return
|
|
if(!on)
|
|
return 0
|
|
|
|
var/output_starting_pressure = air2.return_pressure()
|
|
if( (target_pressure - output_starting_pressure) < 0.01) //No need to pump gas if target is already reached!
|
|
update_power_usage(0)
|
|
return 1
|
|
|
|
var/output_volume = air2.volume
|
|
if (network2 && network2.air_transient)
|
|
output_volume = network2.air_transient.volume //note that the amount of gas in the adjacent pipe will still limit what we can transfer
|
|
|
|
//This is pointless since gas_mixure/remove() won't let as remove more than is in the adjacent pipe anyways and removing gas directly from the network is not going to work.
|
|
//output_volume = min(output_volume, max_volume_transfer)
|
|
|
|
//Calculate necessary moles to transfer using PV=nRT
|
|
if((air1.total_moles() > 0) && (air1.temperature > 0 || air2.temperature > 0))
|
|
var/air_temperature = (air2.temperature > 0)? air2.temperature : air1.temperature
|
|
var/pressure_delta = target_pressure - output_starting_pressure
|
|
var/transfer_moles = pressure_delta*output_volume/(air_temperature * R_IDEAL_GAS_EQUATION) //The number of moles that would have to be transfered to bring air2 to the target pressure
|
|
|
|
//estimate the amount of energy required
|
|
var/specific_entropy = air2.specific_entropy() - air1.specific_entropy() //air2 is gaining moles, air1 is loosing
|
|
var/specific_power = 0 // W/mol
|
|
|
|
//if specific_entropy >= 0 then gas just flows naturally and we are not limited by how powerful the pump is.
|
|
if (specific_entropy < 0)
|
|
specific_power = -specific_entropy*air_temperature //how much power we need per mole
|
|
transfer_moles = min(transfer_moles, active_power_usage / specific_power)
|
|
|
|
//Actually transfer the gas
|
|
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
|
|
air2.merge(removed)
|
|
|
|
//if specific_entropy >= 0 then gas is flowing naturally and we don't need to use extra power
|
|
if (specific_entropy < 0)
|
|
//pump draws power and heats gas according to 2nd law of thermodynamics
|
|
var/power_draw = round(transfer_moles*specific_power)
|
|
air2.add_thermal_energy(power_draw)
|
|
update_power_usage(power_draw)
|
|
else
|
|
update_power_usage(0)
|
|
|
|
if(network1)
|
|
network1.update = 1
|
|
|
|
if(network2)
|
|
network2.update = 1
|
|
|
|
return 1
|
|
|
|
//Radio remote control
|
|
|
|
/obj/machinery/atmospherics/binary/pump/proc/set_frequency(new_frequency)
|
|
radio_controller.remove_object(src, frequency)
|
|
frequency = new_frequency
|
|
if(frequency)
|
|
radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
|
|
|
/obj/machinery/atmospherics/binary/pump/proc/broadcast_status()
|
|
if(!radio_connection)
|
|
return 0
|
|
|
|
var/datum/signal/signal = new
|
|
signal.transmission_method = 1 //radio signal
|
|
signal.source = src
|
|
|
|
signal.data = list(
|
|
"tag" = id,
|
|
"device" = "AGP",
|
|
"power" = on,
|
|
"target_output" = target_pressure,
|
|
"sigtype" = "status"
|
|
)
|
|
|
|
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
|
|
|
return 1
|
|
|
|
|
|
//this proc handles power usages so that we only have to call use_power() when the pump is loaded but not at full load.
|
|
/obj/machinery/atmospherics/binary/proc/update_power_usage(var/usage_amount)
|
|
if (usage_amount > active_power_usage - 5)
|
|
if (use_power < 2)
|
|
update_use_power(2)
|
|
else
|
|
if (use_power >= 2)
|
|
update_use_power(1)
|
|
|
|
if (usage_amount > idle_power_usage)
|
|
use_power(usage_amount) //in practice it's pretty rare that we will get here, so calling use_power() is alright.
|
|
|
|
last_power_draw = usage_amount
|
|
if (use_power > 0)
|
|
last_power_draw = max(last_power_draw, idle_power_usage)
|
|
|
|
/obj/machinery/atmospherics/binary/proc/turn_on()
|
|
on = 1
|
|
update_use_power(1)
|
|
|
|
/obj/machinery/atmospherics/binary/proc/turn_off()
|
|
on = 0
|
|
last_power_draw = 0
|
|
update_use_power(0)
|
|
|
|
/obj/machinery/atmospherics/binary/pump/ui_interact(mob/user, ui_key = "main", var/datum/nanoui/ui = null)
|
|
if(stat & (BROKEN|NOPOWER))
|
|
return
|
|
|
|
// this is the data which will be sent to the ui
|
|
var/data[0]
|
|
|
|
data = list(
|
|
"on" = on,
|
|
"pressure_set" = round(target_pressure, 0.01),
|
|
"max_pressure" = max_pressure_setting,
|
|
"last_power_draw" = round(last_power_draw),
|
|
"max_power_draw" = active_power_usage,
|
|
)
|
|
|
|
// update the ui if it exists, returns null if no ui is passed/found
|
|
ui = nanomanager.try_update_ui(user, src, ui_key, ui, data)
|
|
if (!ui)
|
|
// the ui does not exist, so we'll create a new() one
|
|
// for a list of parameters and their descriptions see the code docs in \code\modules\nano\nanoui.dm
|
|
ui = new(user, src, ui_key, "gas_pump.tmpl", name, 470, 290)
|
|
ui.set_initial_data(data) // when the ui is first opened this is the data it will use
|
|
ui.open() // open the new ui window
|
|
ui.set_auto_update(1) // auto update every Master Controller tick
|
|
|
|
/obj/machinery/atmospherics/binary/pump/initialize()
|
|
..()
|
|
if(frequency)
|
|
set_frequency(frequency)
|
|
|
|
/obj/machinery/atmospherics/binary/pump/receive_signal(datum/signal/signal)
|
|
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
|
|
return 0
|
|
|
|
if("power" in signal.data)
|
|
if(text2num(signal.data["power"]))
|
|
turn_on()
|
|
else
|
|
turn_off()
|
|
|
|
if("power_toggle" in signal.data)
|
|
if (on)
|
|
turn_off()
|
|
else
|
|
turn_on()
|
|
|
|
if(signal.data["set_output_pressure"])
|
|
target_pressure = between(
|
|
0,
|
|
text2num(signal.data["set_output_pressure"]),
|
|
ONE_ATMOSPHERE*50
|
|
)
|
|
|
|
if(signal.data["status"])
|
|
spawn(2)
|
|
broadcast_status()
|
|
return //do not update_icon
|
|
|
|
spawn(2)
|
|
broadcast_status()
|
|
update_icon()
|
|
return
|
|
|
|
/obj/machinery/atmospherics/binary/pump/attack_hand(user as mob)
|
|
if(..())
|
|
return
|
|
src.add_fingerprint(usr)
|
|
if(!src.allowed(user))
|
|
user << "\red Access denied."
|
|
return
|
|
usr.set_machine(src)
|
|
ui_interact(user)
|
|
return
|
|
|
|
/obj/machinery/atmospherics/binary/pump/Topic(href,href_list)
|
|
if(..()) return
|
|
|
|
if(href_list["power"])
|
|
if (on)
|
|
turn_off()
|
|
else
|
|
turn_on()
|
|
|
|
switch(href_list["set_press"])
|
|
if ("min")
|
|
target_pressure = 0
|
|
if ("max")
|
|
target_pressure = max_pressure_setting
|
|
if ("set")
|
|
var/new_pressure = input(usr,"Enter new output pressure (0-[max_pressure_setting]kPa)","Pressure control",src.target_pressure) as num
|
|
src.target_pressure = max(0, min(max_pressure_setting, new_pressure))
|
|
|
|
usr.set_machine(src)
|
|
src.add_fingerprint(usr)
|
|
|
|
src.update_icon()
|
|
|
|
/obj/machinery/atmospherics/binary/pump/power_change()
|
|
var/old_stat = stat
|
|
..()
|
|
if(old_stat != stat)
|
|
update_icon()
|
|
|
|
/obj/machinery/atmospherics/binary/pump/attackby(var/obj/item/weapon/W as obj, var/mob/user as mob)
|
|
if (!istype(W, /obj/item/weapon/wrench))
|
|
return ..()
|
|
if (!(stat & NOPOWER) && on)
|
|
user << "\red You cannot unwrench this [src], turn it off first."
|
|
return 1
|
|
var/datum/gas_mixture/int_air = return_air()
|
|
var/datum/gas_mixture/env_air = loc.return_air()
|
|
if ((int_air.return_pressure()-env_air.return_pressure()) > 2*ONE_ATMOSPHERE)
|
|
user << "\red You cannot unwrench this [src], it too exerted due to internal pressure."
|
|
add_fingerprint(user)
|
|
return 1
|
|
playsound(src.loc, 'sound/items/Ratchet.ogg', 50, 1)
|
|
user << "\blue You begin to unfasten \the [src]..."
|
|
if (do_after(user, 40))
|
|
user.visible_message( \
|
|
"[user] unfastens \the [src].", \
|
|
"\blue You have unfastened \the [src].", \
|
|
"You hear ratchet.")
|
|
new /obj/item/pipe(loc, make_from=src)
|
|
del(src)
|