// /obj/machinery POWER USAGE CODE HERE! GO GO GADGET STATIC POWER!
|
|
// Note: You can find /obj/machinery/power power usage code in power.dm
|
|
//
|
|
// The following four machinery variables determine the "static" amount of power used every power cycle:
|
|
// - use_power, idle_power_usage, active_power_usage, power_channel
|
|
//
|
|
// Please never change any of these variables! Use the procs that update them instead!
|
|
//
|
|
|
|
// Note that we update the area even if the area is unpowered.
|
|
#define REPORT_POWER_CONSUMPTION_CHANGE(old_power, new_power)\
|
|
if(old_power != new_power){\
|
|
var/area/A = get_area(src);\
|
|
if(A) A.power_use_change(old_power, new_power, power_channel)}
|
|
|
|
// Current power consumption right now.
|
|
#define POWER_CONSUMPTION (use_power == USE_POWER_IDLE ? idle_power_usage : (use_power >= USE_POWER_ACTIVE ? active_power_usage : 0))
|
|
|
|
// returns true if the area has power on given channel (or doesn't require power).
|
|
// defaults to power_channel
|
|
/obj/machinery/proc/powered(var/chan = CURRENT_CHANNEL) // defaults to power_channel
|
|
//Don't do this. It allows machines that set use_power to 0 when off (many machines) to
|
|
//be turned on again and used after a power failure because they never gain the NOPOWER flag.
|
|
//if(!use_power)
|
|
// return 1
|
|
|
|
var/area/A = get_area(src) // make sure it's in an area
|
|
if(!A)
|
|
return 0 // if not, then not powered
|
|
if(chan == CURRENT_CHANNEL)
|
|
chan = power_channel
|
|
return A.powered(chan) // return power status of the area
|
|
|
|
// called whenever the power settings of the containing area change
|
|
// by default, check equipment channel & set/clear NOPOWER flag
|
|
// Returns TRUE if NOPOWER stat flag changed.
|
|
// can override if needed
|
|
/obj/machinery/proc/power_change()
|
|
var/oldstat = stat
|
|
if(powered(power_channel))
|
|
stat &= ~NOPOWER
|
|
else
|
|
stat |= NOPOWER
|
|
return (stat != oldstat)
|
|
|
|
// Get the amount of power this machine will consume each cycle. Override by experts only!
|
|
/obj/machinery/proc/get_power_usage()
|
|
return POWER_CONSUMPTION
|
|
|
|
// DEPRECATED! - USE use_power_oneoff() instead!
|
|
/obj/machinery/proc/use_power(var/amount, var/chan = -1) // defaults to power_channel
|
|
return src.use_power_oneoff(amount, chan);
|
|
|
|
// This will have this machine have its area eat this much power next tick, and not afterwards. Do not use for continued power draw.
|
|
// Returns actual amount drawn (In theory this could be less than the amount asked for. In pratice it won't be FOR NOW)
|
|
/obj/machinery/proc/use_power_oneoff(var/amount, var/chan = CURRENT_CHANNEL)
|
|
var/area/A = get_area(src) // make sure it's in an area
|
|
if(!A)
|
|
return
|
|
if(chan == CURRENT_CHANNEL)
|
|
chan = power_channel
|
|
return A.use_power_oneoff(amount, chan)
|
|
|
|
// Check if we CAN use a given amount of extra power as a one off. Returns amount we could use without actually using it.
|
|
// For backwards compatibilty this returns true if the channel is powered. This is consistant with pre-static-power
|
|
// behavior of APC powerd machines, but at some point we might want to make this a bit cooler.
|
|
/obj/machinery/proc/can_use_power_oneoff(var/amount, var/chan = CURRENT_CHANNEL)
|
|
if(powered(chan))
|
|
return amount // If channel is powered then you can do it.
|
|
return 0
|
|
|
|
/obj/machinery
|
|
var/recursive_set = FALSE //CHOMPEdit: bool to indicate if recursive movement detection ever got set. If it did, don't try to set it again!
|
|
|
|
// Do not do power stuff in New/Initialize until after ..()
|
|
/obj/machinery/Initialize(mapload)
|
|
. = ..()
|
|
|
|
//ChompEDIT START -- only add this if we init on a non-turf (and non-null)
|
|
if(!recursive_set && loc && !isturf(loc))
|
|
recursive_set = TRUE
|
|
AddComponent(/datum/component/recursive_move)
|
|
RegisterSignal(src, COMSIG_OBSERVER_MOVED, PROC_REF(update_power_on_move)) //we only need this for recursive moving
|
|
//ChompEDIT END
|
|
|
|
var/power = POWER_CONSUMPTION
|
|
REPORT_POWER_CONSUMPTION_CHANGE(0, power)
|
|
power_init_complete = TRUE
|
|
|
|
// Or in Destroy at all, but especially after the ..().
|
|
/obj/machinery/Destroy()
|
|
/*
|
|
if(ismovable(loc))
|
|
UnregisterSignal(loc, COMSIG_OBSERVER_MOVED) // Unregister just in case
|
|
*/
|
|
var/power = POWER_CONSUMPTION
|
|
REPORT_POWER_CONSUMPTION_CHANGE(power, 0)
|
|
. = ..()
|
|
|
|
// Registering moved_event observers for all machines is too expensive. Instead we do it ourselves.
|
|
// 99% of machines are always on a turf anyway, very few need recursive move handling.
|
|
/obj/machinery/Moved(atom/old_loc, direction, forced = FALSE)
|
|
. = ..()
|
|
update_power_on_move(src, old_loc, loc)
|
|
|
|
//ChompEDIT START -- only add this if we move into a non-turf (not null) and we've never been given recursive move handling
|
|
if(!recursive_set && loc && !isturf(loc))
|
|
recursive_set = TRUE
|
|
AddComponent(/datum/component/recursive_move)
|
|
RegisterSignal(src, COMSIG_OBSERVER_MOVED, PROC_REF(update_power_on_move)) //we only need this for recursive moving
|
|
//ChompEDIT END
|
|
|
|
/* No
|
|
if(ismovable(old_loc)) // Unregister recursive movement.
|
|
UnregisterSignal(old_loc, COMSIG_OBSERVER_MOVED)
|
|
if(ismovable(loc)) // Register for recursive movement (if the thing we're inside moves)
|
|
RegisterSignal(loc, COMSIG_OBSERVER_MOVED, PROC_REF(update_power_on_move), override = TRUE)
|
|
*/
|
|
|
|
/obj/machinery/proc/update_power_on_move(atom/movable/mover, atom/old_loc, atom/new_loc)
|
|
SIGNAL_HANDLER
|
|
var/area/old_area = get_area(old_loc)
|
|
var/area/new_area = get_area(new_loc)
|
|
if(old_area != new_area)
|
|
area_changed(old_area, new_area)
|
|
|
|
/obj/machinery/proc/area_changed(area/old_area, area/new_area)
|
|
if(old_area == new_area || !power_init_complete)
|
|
return
|
|
var/power = POWER_CONSUMPTION
|
|
if(!power)
|
|
return // This is the most likely case anyway.
|
|
|
|
if(old_area)
|
|
old_area.power_use_change(power, 0, power_channel) // Remove our usage from old area
|
|
if(new_area)
|
|
new_area.power_use_change(0, power, power_channel) // Add our usage to new area
|
|
power_change() // Force check in case the old area was powered and the new one isn't or vice versa.
|
|
|
|
//
|
|
// Usage Update Procs - These procs are the only allowed way to modify these four variables:
|
|
// - use_power, idle_power_usage, active_power_usage, power_channel
|
|
//
|
|
|
|
// Sets the use_power var and then forces an area power update
|
|
/obj/machinery/proc/update_use_power(var/new_use_power)
|
|
if(use_power == new_use_power)
|
|
return
|
|
if(!power_init_complete)
|
|
use_power = new_use_power
|
|
return TRUE // We'll be retallying anyway.
|
|
var/old_power = POWER_CONSUMPTION
|
|
use_power = new_use_power
|
|
var/new_power = POWER_CONSUMPTION
|
|
REPORT_POWER_CONSUMPTION_CHANGE(old_power, new_power)
|
|
return TRUE
|
|
|
|
// Sets the power_channel var and then forces an area power update.
|
|
/obj/machinery/proc/update_power_channel(var/new_channel)
|
|
if(power_channel == new_channel)
|
|
return
|
|
if(!power_init_complete)
|
|
power_channel = new_channel
|
|
return TRUE // We'll be retallying anyway.
|
|
var/power = POWER_CONSUMPTION
|
|
REPORT_POWER_CONSUMPTION_CHANGE(power, 0) // Subtract from old channel
|
|
power_channel = new_channel
|
|
REPORT_POWER_CONSUMPTION_CHANGE(0, power) // Add to new channel
|
|
return TRUE
|
|
|
|
// Sets the idle_power_usage var and then forces an area power update if use_power was USE_POWER_IDLE
|
|
/obj/machinery/proc/update_idle_power_usage(var/new_power_usage)
|
|
if(idle_power_usage == new_power_usage)
|
|
return
|
|
var/old_power = idle_power_usage
|
|
idle_power_usage = new_power_usage
|
|
if(power_init_complete && use_power == USE_POWER_IDLE) // If this is the channel in use
|
|
REPORT_POWER_CONSUMPTION_CHANGE(old_power, new_power_usage)
|
|
|
|
// Sets the active_power_usage var and then forces an area power update if use_power was USE_POWER_ACTIVE
|
|
/obj/machinery/proc/update_active_power_usage(var/new_power_usage)
|
|
if(active_power_usage == new_power_usage)
|
|
return
|
|
var/old_power = active_power_usage
|
|
active_power_usage = new_power_usage
|
|
if(power_init_complete && use_power == USE_POWER_ACTIVE) // If this is the channel in use
|
|
REPORT_POWER_CONSUMPTION_CHANGE(old_power, new_power_usage)
|
|
|
|
#undef REPORT_POWER_CONSUMPTION_CHANGE
|
|
#undef POWER_CONSUMPTION
|