// Wires for airlocks
/datum/wires/airlock/secure
random = 1
wire_count = 14
window_y = 680
/datum/wires/airlock
holder_type = /obj/machinery/door/airlock
wire_count = 12
window_y = 570
var/const/AIRLOCK_WIRE_IDSCAN = 1
var/const/AIRLOCK_WIRE_MAIN_POWER1 = 2
var/const/AIRLOCK_WIRE_MAIN_POWER2 = 4
var/const/AIRLOCK_WIRE_DOOR_BOLTS = 8
var/const/AIRLOCK_WIRE_BACKUP_POWER1 = 16
var/const/AIRLOCK_WIRE_BACKUP_POWER2 = 32
var/const/AIRLOCK_WIRE_OPEN_DOOR = 64
var/const/AIRLOCK_WIRE_AI_CONTROL = 128
var/const/AIRLOCK_WIRE_ELECTRIFY = 256
var/const/AIRLOCK_WIRE_SAFETY = 512
var/const/AIRLOCK_WIRE_SPEED = 1024
var/const/AIRLOCK_WIRE_LIGHT = 2048
/datum/wires/airlock/CanUse(var/mob/living/L)
var/obj/machinery/door/airlock/A = holder
if(!istype(L, /mob/living/silicon))
if(A.isElectrified())
if(A.shock(L, 100))
return 0
if(A.p_open)
return 1
return 0
/datum/wires/airlock/GetInteractWindow()
var/obj/machinery/door/airlock/A = holder
var/haspower = A.arePowerSystemsOn() //If there's no power, then no lights will be on.
. += ..()
. += show_hint(0x01, A.locked, "The door bolts have fallen!", "The door bolts look up.")
. += show_hint(0x02, A.lights && haspower, "The door bolt lights are on.", "The door bolt lights are off!")
. += show_hint(0x04, haspower, "The test light is on.", "The test light is off!")
. += show_hint(0x08, A.backup_power_lost_until, "The backup power light is off!", "The backup power light is on.")
. += show_hint(0x10, A.aiControlDisabled == 0 && !A.emagged && haspower, "The 'AI control allowed' light is on.", "The 'AI control allowed' light is off.")
. += show_hint(0x20, A.safe == 0 && haspower, "The 'Check Wiring' light is on.", "The 'Check Wiring' light is off.")
. += show_hint(0x40, A.normalspeed == 0 && haspower, "The 'Check Timing Mechanism' light is on.", "The 'Check Timing Mechanism' light is off.")
. += show_hint(0x80, A.aiDisabledIdScanner == 0 && haspower, "The IDScan light is on.", "The IDScan light is off.")
/datum/wires/airlock/UpdateCut(var/index, var/mended)
var/obj/machinery/door/airlock/A = holder
switch(index)
if(AIRLOCK_WIRE_IDSCAN)
A.aiDisabledIdScanner = !mended
if(AIRLOCK_WIRE_MAIN_POWER1, AIRLOCK_WIRE_MAIN_POWER2)
if(!mended)
//Cutting either one disables the main door power, but unless backup power is also cut, the backup power re-powers the door in 10 seconds. While unpowered, the door may be crowbarred open, but bolts-raising will not work. Cutting these wires may electocute the user.
A.loseMainPower()
A.shock(usr, 50)
else
A.regainMainPower()
A.shock(usr, 50)
if(AIRLOCK_WIRE_BACKUP_POWER1, AIRLOCK_WIRE_BACKUP_POWER2)
if(!mended)
//Cutting either one disables the backup door power (allowing it to be crowbarred open, but disabling bolts-raising), but may electocute the user.
A.loseBackupPower()
A.shock(usr, 50)
else
A.regainBackupPower()
A.shock(usr, 50)
if(AIRLOCK_WIRE_DOOR_BOLTS)
if(!mended)
//Cutting this wire also drops the door bolts, and mending it does not raise them. (This is what happens now, except there are a lot more wires going to door bolts at present)
A.lock(1)
A.update_icon()
if(AIRLOCK_WIRE_AI_CONTROL)
if(!mended)
//one wire for AI control. Cutting this prevents the AI from controlling the door unless it has hacked the door through the power connection (which takes about a minute). If both main and backup power are cut, as well as this wire, then the AI cannot operate or hack the door at all.
//aiControlDisabled: If 1, AI control is disabled until the AI hacks back in and disables the lock. If 2, the AI has bypassed the lock. If -1, the control is enabled but the AI had bypassed it earlier, so if it is disabled again the AI would have no trouble getting back in.
if(A.aiControlDisabled == 0)
A.aiControlDisabled = 1
else if(A.aiControlDisabled == -1)
A.aiControlDisabled = 2
else
if(A.aiControlDisabled == 1)
A.aiControlDisabled = 0
else if(A.aiControlDisabled == 2)
A.aiControlDisabled = -1
if(AIRLOCK_WIRE_ELECTRIFY)
if(!mended)
//Cutting this wire electrifies the door, so that the next person to touch the door without insulated gloves gets electrocuted.
A.electrify(-1)
else
A.electrify(0)
return // Don't update the dialog.
if (AIRLOCK_WIRE_SAFETY)
A.safe = mended
if(AIRLOCK_WIRE_SPEED)
A.autoclose = mended
if(mended)
if(!A.density)
A.close()
if(AIRLOCK_WIRE_LIGHT)
A.lights = mended
A.update_icon()
/datum/wires/airlock/UpdatePulsed(var/index)
var/obj/machinery/door/airlock/A = holder
switch(index)
if(AIRLOCK_WIRE_IDSCAN)
//Sending a pulse through flashes the red light on the door (if the door has power).
if(A.arePowerSystemsOn() && A.density)
A.do_animate("deny")
if(AIRLOCK_WIRE_MAIN_POWER1, AIRLOCK_WIRE_MAIN_POWER2)
//Sending a pulse through either one causes a breaker to trip, disabling the door for 10 seconds if backup power is connected, or 1 minute if not (or until backup power comes back on, whichever is shorter).
A.loseMainPower()
if(AIRLOCK_WIRE_DOOR_BOLTS)
//one wire for door bolts. Sending a pulse through this drops door bolts if they're not down (whether power's on or not),
//raises them if they are down (only if power's on)
if(!A.locked)
A.lock()
else
A.unlock()
if(AIRLOCK_WIRE_BACKUP_POWER1, AIRLOCK_WIRE_BACKUP_POWER2)
//two wires for backup power. Sending a pulse through either one causes a breaker to trip, but this does not disable it unless main power is down too (in which case it is disabled for 1 minute or however long it takes main power to come back, whichever is shorter).
A.loseBackupPower()
if(AIRLOCK_WIRE_AI_CONTROL)
if(A.aiControlDisabled == 0)
A.aiControlDisabled = 1
else if(A.aiControlDisabled == -1)
A.aiControlDisabled = 2
spawn(10)
if(A)
if(A.aiControlDisabled == 1)
A.aiControlDisabled = 0
else if(A.aiControlDisabled == 2)
A.aiControlDisabled = -1
if(AIRLOCK_WIRE_ELECTRIFY)
//one wire for electrifying the door. Sending a pulse through this electrifies the door for 30 seconds.
A.electrify(30)
if(AIRLOCK_WIRE_OPEN_DOOR)
//tries to open the door without ID
//will succeed only if the ID wire is cut or the door requires no access and it's not emagged
if(A.emagged) return
if(!A.requiresID() || A.check_access(null))
if(A.density) A.open()
else A.close()
if(AIRLOCK_WIRE_SAFETY)
A.safe = !A.safe
if(!A.density)
A.close()
if(AIRLOCK_WIRE_SPEED)
A.normalspeed = !A.normalspeed
if(AIRLOCK_WIRE_LIGHT)
A.lights = !A.lights
A.update_icon()