// Wires for airlocks
|
|
|
|
/datum/wires/airlock/secure
|
|
random = 1
|
|
wire_count = 14
|
|
window_y = 680
|
|
|
|
/datum/wires/airlock
|
|
holder_type = /obj/machinery/door/airlock
|
|
wire_count = 12
|
|
window_y = 570
|
|
|
|
var/const/AIRLOCK_WIRE_IDSCAN = 1
|
|
var/const/AIRLOCK_WIRE_MAIN_POWER1 = 2
|
|
var/const/AIRLOCK_WIRE_MAIN_POWER2 = 4
|
|
var/const/AIRLOCK_WIRE_DOOR_BOLTS = 8
|
|
var/const/AIRLOCK_WIRE_BACKUP_POWER1 = 16
|
|
var/const/AIRLOCK_WIRE_BACKUP_POWER2 = 32
|
|
var/const/AIRLOCK_WIRE_OPEN_DOOR = 64
|
|
var/const/AIRLOCK_WIRE_AI_CONTROL = 128
|
|
var/const/AIRLOCK_WIRE_ELECTRIFY = 256
|
|
var/const/AIRLOCK_WIRE_SAFETY = 512
|
|
var/const/AIRLOCK_WIRE_SPEED = 1024
|
|
var/const/AIRLOCK_WIRE_LIGHT = 2048
|
|
|
|
/datum/wires/airlock/CanUse(var/mob/living/L)
|
|
var/obj/machinery/door/airlock/A = holder
|
|
if(!istype(L, /mob/living/silicon))
|
|
if(A.isElectrified())
|
|
if(A.shock(L, 100))
|
|
return 0
|
|
if(A.p_open)
|
|
return 1
|
|
return 0
|
|
|
|
/datum/wires/airlock/GetInteractWindow()
|
|
var/obj/machinery/door/airlock/A = holder
|
|
var/haspower = A.arePowerSystemsOn() //If there's no power, then no lights will be on.
|
|
|
|
. += ..()
|
|
. += show_hint(0x01, A.locked, "The door bolts have fallen!", "The door bolts look up.")
|
|
. += show_hint(0x02, A.lights && haspower, "The door bolt lights are on.", "The door bolt lights are off!")
|
|
. += show_hint(0x04, haspower, "The test light is on.", "The test light is off!")
|
|
. += show_hint(0x08, A.backup_power_lost_until, "The backup power light is off!", "The backup power light is on.")
|
|
. += show_hint(0x10, A.aiControlDisabled == 0 && !A.emagged && haspower, "The 'AI control allowed' light is on.", "The 'AI control allowed' light is off.")
|
|
. += show_hint(0x20, A.safe == 0 && haspower, "The 'Check Wiring' light is on.", "The 'Check Wiring' light is off.")
|
|
. += show_hint(0x40, A.normalspeed == 0 && haspower, "The 'Check Timing Mechanism' light is on.", "The 'Check Timing Mechanism' light is off.")
|
|
. += show_hint(0x80, A.aiDisabledIdScanner == 0 && haspower, "The IDScan light is on.", "The IDScan light is off.")
|
|
|
|
/datum/wires/airlock/UpdateCut(var/index, var/mended)
|
|
|
|
var/obj/machinery/door/airlock/A = holder
|
|
switch(index)
|
|
if(AIRLOCK_WIRE_IDSCAN)
|
|
A.aiDisabledIdScanner = !mended
|
|
if(AIRLOCK_WIRE_MAIN_POWER1, AIRLOCK_WIRE_MAIN_POWER2)
|
|
|
|
if(!mended)
|
|
//Cutting either one disables the main door power, but unless backup power is also cut, the backup power re-powers the door in 10 seconds. While unpowered, the door may be crowbarred open, but bolts-raising will not work. Cutting these wires may electocute the user.
|
|
A.loseMainPower()
|
|
A.shock(usr, 50)
|
|
else
|
|
A.regainMainPower()
|
|
A.shock(usr, 50)
|
|
|
|
if(AIRLOCK_WIRE_BACKUP_POWER1, AIRLOCK_WIRE_BACKUP_POWER2)
|
|
|
|
if(!mended)
|
|
//Cutting either one disables the backup door power (allowing it to be crowbarred open, but disabling bolts-raising), but may electocute the user.
|
|
A.loseBackupPower()
|
|
A.shock(usr, 50)
|
|
else
|
|
A.regainBackupPower()
|
|
A.shock(usr, 50)
|
|
|
|
if(AIRLOCK_WIRE_DOOR_BOLTS)
|
|
|
|
if(!mended)
|
|
//Cutting this wire also drops the door bolts, and mending it does not raise them. (This is what happens now, except there are a lot more wires going to door bolts at present)
|
|
A.lock(1)
|
|
A.update_icon()
|
|
|
|
if(AIRLOCK_WIRE_AI_CONTROL)
|
|
|
|
if(!mended)
|
|
//one wire for AI control. Cutting this prevents the AI from controlling the door unless it has hacked the door through the power connection (which takes about a minute). If both main and backup power are cut, as well as this wire, then the AI cannot operate or hack the door at all.
|
|
//aiControlDisabled: If 1, AI control is disabled until the AI hacks back in and disables the lock. If 2, the AI has bypassed the lock. If -1, the control is enabled but the AI had bypassed it earlier, so if it is disabled again the AI would have no trouble getting back in.
|
|
if(A.aiControlDisabled == 0)
|
|
A.aiControlDisabled = 1
|
|
else if(A.aiControlDisabled == -1)
|
|
A.aiControlDisabled = 2
|
|
else
|
|
if(A.aiControlDisabled == 1)
|
|
A.aiControlDisabled = 0
|
|
else if(A.aiControlDisabled == 2)
|
|
A.aiControlDisabled = -1
|
|
|
|
if(AIRLOCK_WIRE_ELECTRIFY)
|
|
if(!mended)
|
|
//Cutting this wire electrifies the door, so that the next person to touch the door without insulated gloves gets electrocuted.
|
|
A.electrify(-1)
|
|
else
|
|
A.electrify(0)
|
|
return // Don't update the dialog.
|
|
|
|
if (AIRLOCK_WIRE_SAFETY)
|
|
A.safe = mended
|
|
|
|
if(AIRLOCK_WIRE_SPEED)
|
|
A.autoclose = mended
|
|
if(mended)
|
|
if(!A.density)
|
|
A.close()
|
|
|
|
if(AIRLOCK_WIRE_LIGHT)
|
|
A.lights = mended
|
|
A.update_icon()
|
|
|
|
|
|
/datum/wires/airlock/UpdatePulsed(var/index)
|
|
|
|
var/obj/machinery/door/airlock/A = holder
|
|
switch(index)
|
|
if(AIRLOCK_WIRE_IDSCAN)
|
|
//Sending a pulse through flashes the red light on the door (if the door has power).
|
|
if(A.arePowerSystemsOn() && A.density)
|
|
A.do_animate("deny")
|
|
if(AIRLOCK_WIRE_MAIN_POWER1, AIRLOCK_WIRE_MAIN_POWER2)
|
|
//Sending a pulse through either one causes a breaker to trip, disabling the door for 10 seconds if backup power is connected, or 1 minute if not (or until backup power comes back on, whichever is shorter).
|
|
A.loseMainPower()
|
|
if(AIRLOCK_WIRE_DOOR_BOLTS)
|
|
//one wire for door bolts. Sending a pulse through this drops door bolts if they're not down (whether power's on or not),
|
|
//raises them if they are down (only if power's on)
|
|
if(!A.locked)
|
|
A.lock()
|
|
else
|
|
A.unlock()
|
|
|
|
if(AIRLOCK_WIRE_BACKUP_POWER1, AIRLOCK_WIRE_BACKUP_POWER2)
|
|
//two wires for backup power. Sending a pulse through either one causes a breaker to trip, but this does not disable it unless main power is down too (in which case it is disabled for 1 minute or however long it takes main power to come back, whichever is shorter).
|
|
A.loseBackupPower()
|
|
if(AIRLOCK_WIRE_AI_CONTROL)
|
|
if(A.aiControlDisabled == 0)
|
|
A.aiControlDisabled = 1
|
|
else if(A.aiControlDisabled == -1)
|
|
A.aiControlDisabled = 2
|
|
|
|
spawn(10)
|
|
if(A)
|
|
if(A.aiControlDisabled == 1)
|
|
A.aiControlDisabled = 0
|
|
else if(A.aiControlDisabled == 2)
|
|
A.aiControlDisabled = -1
|
|
|
|
if(AIRLOCK_WIRE_ELECTRIFY)
|
|
//one wire for electrifying the door. Sending a pulse through this electrifies the door for 30 seconds.
|
|
A.electrify(30)
|
|
if(AIRLOCK_WIRE_OPEN_DOOR)
|
|
//tries to open the door without ID
|
|
//will succeed only if the ID wire is cut or the door requires no access and it's not emagged
|
|
if(A.emagged) return
|
|
if(!A.requiresID() || A.check_access(null))
|
|
if(A.density) A.open()
|
|
else A.close()
|
|
if(AIRLOCK_WIRE_SAFETY)
|
|
A.safe = !A.safe
|
|
if(!A.density)
|
|
A.close()
|
|
|
|
if(AIRLOCK_WIRE_SPEED)
|
|
A.normalspeed = !A.normalspeed
|
|
|
|
if(AIRLOCK_WIRE_LIGHT)
|
|
A.lights = !A.lights
|
|
A.update_icon()
|