mirror of
https://github.com/CHOMPStation2/CHOMPStation2.git
synced 2025-12-11 10:43:20 +00:00
77 lines
2.7 KiB
Plaintext
77 lines
2.7 KiB
Plaintext
SUBSYSTEM_DEF(nightshift)
|
|
name = "Night Shift"
|
|
dependencies = list(
|
|
/datum/controller/subsystem/lighting
|
|
)
|
|
priority = FIRE_PRIORITY_NIGHTSHIFT
|
|
wait = 60 SECONDS
|
|
|
|
var/nightshift_active = FALSE
|
|
var/nightshift_first_check = 30 SECONDS
|
|
|
|
var/high_security_mode = FALSE
|
|
var/list/currentrun
|
|
|
|
/datum/controller/subsystem/nightshift/Initialize()
|
|
if(!CONFIG_GET(flag/enable_night_shifts))
|
|
can_fire = FALSE
|
|
return SS_INIT_SUCCESS
|
|
|
|
/datum/controller/subsystem/nightshift/fire(resumed = FALSE)
|
|
if(resumed)
|
|
update_nightshift(resumed = TRUE)
|
|
return
|
|
if(world.time - SSticker.round_start_time < nightshift_first_check)
|
|
return
|
|
check_nightshift()
|
|
|
|
/datum/controller/subsystem/nightshift/proc/announce(message)
|
|
var/announce_z
|
|
if(using_map.station_levels.len)
|
|
announce_z = pick(using_map.station_levels)
|
|
/* CHOMPEdit - TTSless
|
|
//VOREStation Edit - TTS
|
|
var/pickedsound
|
|
if(!high_security_mode)
|
|
if(nightshift_active)
|
|
pickedsound = 'sound/AI/dim_lights.ogg'
|
|
else
|
|
pickedsound = 'sound/AI/bright_lights.ogg'
|
|
*/
|
|
priority_announcement.Announce(message, new_title = "Automated Lighting System Announcement", /* new_sound = pickedsound,*/ zlevel = announce_z)
|
|
// CHOMPEdit End
|
|
//VOREStation Edit End
|
|
|
|
/datum/controller/subsystem/nightshift/proc/check_nightshift(forced) //This is called from elsewhere, like setting the alert levels, sadly
|
|
var/emergency = GLOB.security_level > SEC_LEVEL_GREEN
|
|
var/announcing = TRUE
|
|
var/night_time = using_map.get_nightshift()
|
|
if(high_security_mode != emergency)
|
|
high_security_mode = emergency
|
|
if(night_time)
|
|
announcing = FALSE
|
|
if(!emergency)
|
|
announce("Restoring night lighting configuration to normal operation.")
|
|
else
|
|
announce("Disabling night lighting: Station is in a state of emergency.")
|
|
if(emergency)
|
|
night_time = FALSE
|
|
if(nightshift_active != night_time)
|
|
update_nightshift(night_time, announcing, forced = forced)
|
|
|
|
/datum/controller/subsystem/nightshift/proc/update_nightshift(active, announce = TRUE, resumed = FALSE, forced = FALSE)
|
|
if(!resumed)
|
|
currentrun = GLOB.apcs
|
|
nightshift_active = active
|
|
if(announce)
|
|
if (active)
|
|
announce("Good evening, crew. To reduce power consumption and stimulate the circadian rhythms of some species, all of the lights aboard the station have been dimmed for the night.")
|
|
else
|
|
announce("Good morning, crew. As it is now day time, all of the lights aboard the station have been restored to their former brightness.")
|
|
for(var/obj/machinery/power/apc/apc as anything in currentrun)
|
|
currentrun -= apc
|
|
if(apc.z in using_map.station_levels)
|
|
apc.set_nightshift(active, TRUE)
|
|
if(MC_TICK_CHECK && !forced) // subsystem will be in state SS_IDLE if forced by an admin
|
|
return
|