// POWERNET SENSOR
|
|
//
|
|
// Last Change 31.12.2014 by Atlantis
|
|
//
|
|
// Powernet sensors are devices which relay information about connected powernet. This information may be relayed
|
|
// via two procs. Proc return_reading_text will return fully HTML styled string which contains all information. This
|
|
// may be used in PDAs or similar applications. Second proc, return_reading_data will return list containing needed data.
|
|
// This is used in NanoUI, for example.
|
|
|
|
/obj/machinery/power/sensor
|
|
name = "Powernet Sensor"
|
|
desc = "Small machine which transmits data about specific powernet"
|
|
anchored = TRUE
|
|
density = FALSE
|
|
layer = ABOVE_UTILITY
|
|
icon = 'icons/obj/objects.dmi'
|
|
icon_state = "floor_beacon" // If anyone wants to make better sprite, feel free to do so without asking me.
|
|
|
|
var/name_tag = "#UNKN#" // ID tag displayed in list of powernet sensors. Each sensor should have it's own tag!
|
|
var/long_range = 0 // If 1, sensor reading will show on all computers, regardless of Zlevel
|
|
|
|
var/list/history = list()
|
|
var/record_size = 60
|
|
var/record_interval = 50
|
|
var/next_record = 0
|
|
var/is_secret_monitor = FALSE
|
|
|
|
// Proc: Initialize(mapload)
|
|
// Parameters: None
|
|
// Description: Automatically assigns name according to ID tag.
|
|
/obj/machinery/power/sensor/Initialize(mapload)
|
|
. = ..()
|
|
auto_set_name()
|
|
history["supply"] = list()
|
|
history["demand"] = list()
|
|
|
|
// Proc: auto_set_name()
|
|
// Parameters: None
|
|
// Description: Sets name of this sensor according to the ID tag.
|
|
/obj/machinery/power/sensor/proc/auto_set_name()
|
|
name = "[name_tag] - Powernet Sensor"
|
|
|
|
/obj/machinery/power/sensor/Destroy()
|
|
. = ..()
|
|
// TODO - Switch power_monitor to register deletion events instead of this.
|
|
for(var/obj/machinery/computer/power_monitor/PM in GLOB.machines)
|
|
if(PM.power_monitor)
|
|
PM.power_monitor.refresh_sensors()
|
|
history.Cut()
|
|
history = null
|
|
|
|
// Proc: check_grid_warning()
|
|
// Parameters: None
|
|
// Description: Checks connected powernet for warnings. If warning is found returns 1
|
|
/obj/machinery/power/sensor/proc/check_grid_warning()
|
|
connect_to_network()
|
|
if(powernet)
|
|
if(powernet.problem)
|
|
return 1
|
|
return 0
|
|
|
|
// Proc: process()
|
|
// Parameters: None
|
|
// Description: This tracks historical usage, for TGUI power monitors
|
|
/obj/machinery/power/sensor/process()
|
|
if(!powernet)
|
|
use_power = USE_POWER_IDLE
|
|
connect_to_network()
|
|
else
|
|
use_power = USE_POWER_ACTIVE
|
|
record()
|
|
return 1
|
|
|
|
// This tracks historical usage, for TGUI power monitors
|
|
/obj/machinery/power/sensor/proc/record()
|
|
if(world.time >= next_record)
|
|
next_record = world.time + record_interval
|
|
|
|
var/datum/powernet/connected_powernet = powernet
|
|
|
|
var/list/supply = history["supply"]
|
|
if(connected_powernet)
|
|
supply += connected_powernet.viewavail
|
|
if(supply.len > record_size)
|
|
supply.Cut(1, 2)
|
|
|
|
var/list/demand = history["demand"]
|
|
if(connected_powernet)
|
|
demand += connected_powernet.viewload
|
|
if(demand.len > record_size)
|
|
demand.Cut(1, 2)
|
|
|
|
/obj/machinery/power/sensor/tgui_data()
|
|
var/list/data = list()
|
|
|
|
data["name"] = name_tag
|
|
data["stored"] = record_size
|
|
data["interval"] = record_interval / 10
|
|
data["attached"] = !!powernet
|
|
data["history"] = history
|
|
|
|
data["areas"] = list()
|
|
if(powernet)
|
|
for(var/obj/machinery/power/terminal/term in powernet.nodes)
|
|
if(istype(term.master, /obj/machinery/power/apc))
|
|
var/obj/machinery/power/apc/A = term.master
|
|
if(istype(A))
|
|
var/cell_charge
|
|
if(!A.cell)
|
|
cell_charge = 0
|
|
else
|
|
cell_charge = A.cell.percent()
|
|
data["areas"] += list(list(
|
|
"name" = A.area.name,
|
|
"charge" = cell_charge,
|
|
"load" = DisplayPower(A.lastused_total),
|
|
"charging" = A.charging,
|
|
"eqp" = A.equipment,
|
|
"lgt" = A.lighting,
|
|
"env" = A.environ,
|
|
))
|
|
|
|
return data
|
|
|
|
// Proc: reading_to_text()
|
|
// Parameters: 1 (amount - Power in Watts to be converted to W, kW or MW)
|
|
// Description: Helper proc that converts reading in Watts to kW or MW (returns string version of amount parameter)
|
|
/obj/machinery/power/sensor/proc/reading_to_text(var/amount = 0)
|
|
var/units = ""
|
|
// 10kW and less - Watts
|
|
if(amount < 10000)
|
|
units = "W"
|
|
// 10MW and less - KiloWatts
|
|
else if(amount < 10000000)
|
|
units = "kW"
|
|
amount = (round(amount/100) / 10)
|
|
// More than 10MW - MegaWatts
|
|
else
|
|
units = "MW"
|
|
amount = (round(amount/10000) / 100)
|
|
if (units == "W")
|
|
return "[amount] W"
|
|
else
|
|
return "~[amount] [units]" //kW and MW are only approximate readings, therefore add "~"
|
|
|
|
// Proc: find_apcs()
|
|
// Parameters: None
|
|
// Description: Searches powernet for APCs and returns them in a list.
|
|
/obj/machinery/power/sensor/proc/find_apcs()
|
|
if(!powernet)
|
|
return
|
|
|
|
var/list/L = list()
|
|
for(var/obj/machinery/power/terminal/term in powernet.nodes)
|
|
if(istype(term.master, /obj/machinery/power/apc))
|
|
var/obj/machinery/power/apc/A = term.master
|
|
L += A
|
|
|
|
return L
|
|
|
|
|
|
// Proc: return_reading_text()
|
|
// Parameters: None
|
|
// Description: Generates string which contains HTML table with reading data.
|
|
/obj/machinery/power/sensor/proc/return_reading_text()
|
|
// No powernet. Try to connect to one first.
|
|
if(!powernet)
|
|
connect_to_network()
|
|
var/out = ""
|
|
if(!powernet) // No powernet.
|
|
out = "# SYSTEM ERROR - NO POWERNET #"
|
|
return out
|
|
|
|
|
|
var/list/L = find_apcs()
|
|
var/total_apc_load = 0
|
|
if(L.len <= 0) // No APCs found.
|
|
out = span_bold("No APCs located in connected powernet!")
|
|
else // APCs found. Create very ugly (but working!) HTML table.
|
|
|
|
out += "<table><tr><th>Name<th>EQUIP<th>LIGHT<th>ENVIRON<th>CELL<th>LOAD"
|
|
|
|
// These lists are used as replacement for number based APC settings
|
|
var/list/S = list("M-OFF","A-OFF","M-ON", "A-ON")
|
|
var/list/chg = list("N","C","F")
|
|
|
|
// Split to multiple lines to make it more readable
|
|
for(var/obj/machinery/power/apc/A in L)
|
|
out += "<tr><td>\The [A.area]" // Add area name
|
|
out += "<td>[S[A.equipment+1]]<td>[S[A.lighting+1]]<td>[S[A.environ+1]]" // Show status of channels
|
|
if(A.cell)
|
|
out += "<td>[round(A.cell.percent())]% - [chg[A.charging+1]]"
|
|
else
|
|
out += "<td>NO CELL"
|
|
var/load = A.lastused_total // Load.
|
|
total_apc_load += load
|
|
load = reading_to_text(load)
|
|
out += "<td>[load]"
|
|
|
|
out += "<br><b>TOTAL AVAILABLE: [reading_to_text(powernet.avail)]</b>"
|
|
out += "<br><b>APC LOAD: [reading_to_text(total_apc_load)]</b>"
|
|
out += "<br><b>OTHER LOAD: [reading_to_text(max(powernet.load - total_apc_load, 0))]</b>"
|
|
out += "<br><b>TOTAL GRID LOAD: [reading_to_text(powernet.viewload)] ([round((powernet.load / powernet.avail) * 100)]%)</b>"
|
|
|
|
if(powernet.problem)
|
|
out += "<br><b>WARNING: Abnormal grid activity detected!</b>"
|
|
return out
|
|
|
|
// Proc: return_reading_data()
|
|
// Parameters: None
|
|
// Description: Generates list containing all powernet data. Optimised for usage with NanoUI
|
|
/obj/machinery/power/sensor/proc/return_reading_data()
|
|
// No powernet. Try to connect to one first.
|
|
if(!powernet)
|
|
connect_to_network()
|
|
var/list/data = list()
|
|
data["name"] = name_tag
|
|
if(!powernet)
|
|
data["error"] = "# SYSTEM ERROR - NO POWERNET #"
|
|
data["alarm"] = 0 // Runtime Prevention
|
|
return data
|
|
|
|
var/list/L = find_apcs()
|
|
var/total_apc_load = 0
|
|
var/list/APC_data = list()
|
|
if(L.len > 0)
|
|
// These lists are used as replacement for number based APC settings
|
|
var/list/S = list("M-OFF","A-OFF","M-ON", "A-ON")
|
|
var/list/chg = list("N","C","F")
|
|
|
|
for(var/obj/machinery/power/apc/A in L)
|
|
var/list/APC_entry = list()
|
|
// Channel Statuses
|
|
APC_entry["s_equipment"] = S[A.equipment+1]
|
|
APC_entry["s_lighting"] = S[A.lighting+1]
|
|
APC_entry["s_environment"] = S[A.environ+1]
|
|
// Cell Status
|
|
APC_entry["cell_charge"] = A.cell ? round(A.cell.percent()) : "NO CELL"
|
|
APC_entry["cell_status"] = A.cell ? chg[A.charging+1] : "N"
|
|
// Location
|
|
APC_entry["x"] = A.x
|
|
APC_entry["y"] = A.y
|
|
APC_entry["z"] = A.z
|
|
// Other info
|
|
APC_entry["total_load"] = reading_to_text(A.lastused_total)
|
|
// Hopefully removes those goddamn \improper s which are screwing up the UI
|
|
var/N = A.area.name
|
|
if(findtext(N, "\improper"))
|
|
N = copytext(N, 3)
|
|
APC_entry["name"] = N
|
|
// Add data into main list of APC data.
|
|
APC_data += list(APC_entry)
|
|
// Add load of this APC to total APC load calculation
|
|
total_apc_load += A.lastused_total
|
|
data["apc_data"] = APC_data
|
|
data["total_avail"] = reading_to_text(max(powernet.avail, 0))
|
|
data["total_used_apc"] = reading_to_text(max(total_apc_load, 0))
|
|
data["total_used_other"] = reading_to_text(max(powernet.viewload - total_apc_load, 0))
|
|
data["total_used_all"] = reading_to_text(max(powernet.viewload, 0))
|
|
// Prevents runtimes when avail is 0 (division by zero)
|
|
if(powernet.avail)
|
|
data["load_percentage"] = round((powernet.viewload / powernet.avail) * 100)
|
|
else
|
|
data["load_percentage"] = 100
|
|
data["alarm"] = powernet.problem ? 1 : 0
|
|
return data
|