#define CELL_VOLUME 2500 // Liters in a cell.
|
|
#define MOLES_CELLSTANDARD (ONE_ATMOSPHERE*CELL_VOLUME/(T20C*R_IDEAL_GAS_EQUATION)) // Moles in a 2.5 m^3 cell at 101.325 kPa and 20 C.
|
|
|
|
#define O2STANDARD 0.21 // Percentage.
|
|
#define N2STANDARD 0.79
|
|
|
|
#define MOLES_PHORON_VISIBLE 0.7 // Moles in a standard cell after which phoron is visible.
|
|
#define MOLES_O2STANDARD (MOLES_CELLSTANDARD * O2STANDARD) // O2 standard value (21%)
|
|
#define MOLES_N2STANDARD (MOLES_CELLSTANDARD * N2STANDARD) // N2 standard value (79%)
|
|
#define MOLES_O2ATMOS (MOLES_O2STANDARD*50)
|
|
#define MOLES_N2ATMOS (MOLES_N2STANDARD*50)
|
|
|
|
// These are for when a mob breathes poisonous air.
|
|
#define MIN_TOXIN_DAMAGE 1
|
|
#define MAX_TOXIN_DAMAGE 10
|
|
|
|
#define BREATH_VOLUME 0.5 // Liters in a normal breath.
|
|
#define BREATH_MOLES (ONE_ATMOSPHERE * BREATH_VOLUME / (T20C * R_IDEAL_GAS_EQUATION)) // Amount of air to take a from a tile
|
|
#define BREATH_PERCENTAGE (BREATH_VOLUME / CELL_VOLUME) // Amount of air needed before pass out/suffocation commences.
|
|
#define HUMAN_NEEDED_OXYGEN (MOLES_CELLSTANDARD * BREATH_PERCENTAGE * 0.16)
|
|
#define HUMAN_HEAT_CAPACITY 280000 //J/K For 80kg person
|
|
|
|
#define PRESSURE_DAMAGE_COEFFICIENT 4 // The amount of pressure damage someone takes is equal to (pressure / HAZARD_HIGH_PRESSURE)*PRESSURE_DAMAGE_COEFFICIENT, with the maximum of MAX_PRESSURE_DAMAGE.
|
|
#define MAX_HIGH_PRESSURE_DAMAGE 4 // This used to be 20... I got this much random rage for some retarded decision by polymorph?! Polymorph now lies in a pool of blood with a katana jammed in his spleen. ~Errorage --PS: The katana did less than 20 damage to him :(
|
|
#define LOW_PRESSURE_DAMAGE 2 // The amount of damage someone takes when in a low pressure area. (The pressure threshold is so low that it doesn't make sense to do any calculations, so it just applies this flat value).
|
|
|
|
#define MINIMUM_AIR_RATIO_TO_SUSPEND 0.05 // Minimum ratio of air that must move to/from a tile to suspend group processing
|
|
#define MINIMUM_AIR_TO_SUSPEND (MOLES_CELLSTANDARD * MINIMUM_AIR_RATIO_TO_SUSPEND) // Minimum amount of air that has to move before a group processing can be suspended
|
|
#define MINIMUM_MOLES_DELTA_TO_MOVE (MOLES_CELLSTANDARD * MINIMUM_AIR_RATIO_TO_SUSPEND) // Either this must be active
|
|
#define MINIMUM_TEMPERATURE_TO_MOVE (T20C + 100) // or this (or both, obviously)
|
|
|
|
#define MINIMUM_TEMPERATURE_RATIO_TO_SUSPEND 0.012 // Minimum temperature difference before group processing is suspended.
|
|
#define MINIMUM_TEMPERATURE_DELTA_TO_SUSPEND 4
|
|
#define MINIMUM_TEMPERATURE_DELTA_TO_CONSIDER 0.5 // Minimum temperature difference before the gas temperatures are just set to be equal.
|
|
#define MINIMUM_TEMPERATURE_FOR_SUPERCONDUCTION (T20C + 10)
|
|
#define MINIMUM_TEMPERATURE_START_SUPERCONDUCTION (T20C + 200)
|
|
|
|
// Must be between 0 and 1. Values closer to 1 equalize temperature faster. Should not exceed 0.4, else strange heat flow occurs.
|
|
#define FLOOR_HEAT_TRANSFER_COEFFICIENT 0.4
|
|
#define WALL_HEAT_TRANSFER_COEFFICIENT 0.0
|
|
#define DOOR_HEAT_TRANSFER_COEFFICIENT 0.0
|
|
#define SPACE_HEAT_TRANSFER_COEFFICIENT 0.2 // A hack to partly simulate radiative heat.
|
|
#define OPEN_HEAT_TRANSFER_COEFFICIENT 0.4
|
|
#define WINDOW_HEAT_TRANSFER_COEFFICIENT 0.1 // A hack for now.
|
|
|
|
// Fire damage.
|
|
#define CARBON_LIFEFORM_FIRE_RESISTANCE (T0C + 200)
|
|
#define CARBON_LIFEFORM_FIRE_DAMAGE 4
|
|
|
|
// Phoron fire properties.
|
|
#define PHORON_MINIMUM_BURN_TEMPERATURE (T0C + 126) //400 K - autoignite temperature in tanks and canisters - enclosed environments I guess
|
|
#define PHORON_FLASHPOINT (T0C + 246) //519 K - autoignite temperature in air if that ever gets implemented.
|
|
|
|
//These control the mole ratio of oxidizer and fuel used in the combustion reaction
|
|
#define FIRE_REACTION_OXIDIZER_AMOUNT 3 //should be greater than the fuel amount if fires are going to spread much
|
|
#define FIRE_REACTION_FUEL_AMOUNT 2
|
|
|
|
//These control the speed at which fire burns
|
|
#define FIRE_GAS_BURNRATE_MULT 1
|
|
#define FIRE_LIQUID_BURNRATE_MULT 0.225
|
|
|
|
//If the fire is burning slower than this rate then the reaction is going too slow to be self sustaining and the fire burns itself out.
|
|
//This ensures that fires don't grind to a near-halt while still remaining active forever.
|
|
#define FIRE_GAS_MIN_BURNRATE 0.01
|
|
#define FIRE_LIQUD_MIN_BURNRATE 0.0025
|
|
|
|
//How many moles of fuel are contained within one solid/liquid fuel volume unit
|
|
#define LIQUIDFUEL_AMOUNT_TO_MOL 0.45 //mol/volume unit
|
|
|
|
// XGM gas flags.
|
|
#define XGM_GAS_FUEL 1
|
|
#define XGM_GAS_OXIDIZER 2
|
|
#define XGM_GAS_CONTAMINANT 4
|
|
#define XGM_GAS_FUSION_FUEL 8
|
|
|
|
#define TANK_LEAK_PRESSURE (30.*ONE_ATMOSPHERE) // Tank starts leaking.
|
|
#define TANK_RUPTURE_PRESSURE (40.*ONE_ATMOSPHERE) // Tank spills all contents into atmosphere.
|
|
#define TANK_FRAGMENT_PRESSURE (50.*ONE_ATMOSPHERE) // Boom 3x3 base explosion.
|
|
#define TANK_FRAGMENT_SCALE (10.*ONE_ATMOSPHERE) // +1 for each SCALE kPa above threshold. Was 2 atm.
|
|
|
|
#define NORMPIPERATE 30 // Pipe-insulation rate divisor.
|
|
#define HEATPIPERATE 8 // Heat-exchange pipe insulation.
|
|
#define FLOWFRAC 0.99 // Fraction of gas transfered per process.
|
|
|
|
//Flags for zone sleeping
|
|
#define ZONE_ACTIVE 1
|
|
#define ZONE_SLEEPING 0
|
|
|
|
// Defines how much of certain gas do the Atmospherics tanks start with. Values are in kpa per tile (assuming 20C)
|
|
#define ATMOSTANK_NITROGEN 90000 // A lot of N2 is needed to produce air mix, that's why we keep 90MPa of it
|
|
#define ATMOSTANK_OXYGEN 40000 // O2 is also important for airmix, but not as much as N2 as it's only 21% of it.
|
|
#define ATMOSTANK_CO2 25000 // CO2 and PH are not critically important for station, only for toxins and alternative coolants, no need to store a lot of those.
|
|
#define ATMOSTANK_PHORON 25000
|
|
#define ATMOSTANK_NITROUSOXIDE 10000 // N2O doesn't have a real useful use, i guess it's on station just to allow refilling of sec's riot control canisters?
|
|
|
|
// Used for quickly making certain things allow airflow or not.
|
|
// More complicated, conditional airflow should override CanZASPass().
|
|
#define ATMOS_PASS_YES 1
|
|
#define ATMOS_PASS_NO 0
|
|
#define ATMOS_PASS_DENSITY -1 // Just checks density. |