mirror of
https://github.com/CHOMPStation2/CHOMPStation2.git
synced 2025-12-10 10:12:45 +00:00
529 lines
17 KiB
Plaintext
529 lines
17 KiB
Plaintext
/obj/machinery/air_sensor
|
|
icon = 'icons/obj/stationobjs.dmi'
|
|
icon_state = "gsensor1"
|
|
name = "Gas Sensor"
|
|
|
|
anchored = 1
|
|
var/state = 0
|
|
|
|
var/id_tag
|
|
var/frequency = 1439
|
|
|
|
var/on = 1
|
|
var/output = 3
|
|
//Flags:
|
|
// 1 for pressure
|
|
// 2 for temperature
|
|
// Output >= 4 includes gas composition
|
|
// 4 for oxygen concentration
|
|
// 8 for phoron concentration
|
|
// 16 for nitrogen concentration
|
|
// 32 for carbon dioxide concentration
|
|
|
|
var/datum/radio_frequency/radio_connection
|
|
|
|
/obj/machinery/air_sensor/update_icon()
|
|
icon_state = "gsensor[on]"
|
|
|
|
/obj/machinery/air_sensor/process()
|
|
if(on)
|
|
var/datum/signal/signal = new
|
|
signal.transmission_method = 1 //radio signal
|
|
signal.data["tag"] = id_tag
|
|
signal.data["timestamp"] = world.time
|
|
|
|
var/datum/gas_mixture/air_sample = return_air()
|
|
|
|
if(output&1)
|
|
signal.data["pressure"] = num2text(round(air_sample.return_pressure(),0.1),)
|
|
if(output&2)
|
|
signal.data["temperature"] = round(air_sample.temperature,0.1)
|
|
|
|
if(output>4)
|
|
var/total_moles = air_sample.total_moles
|
|
if(total_moles > 0)
|
|
if(output&4)
|
|
signal.data["oxygen"] = round(100*air_sample.gas["oxygen"]/total_moles,0.1)
|
|
if(output&8)
|
|
signal.data["phoron"] = round(100*air_sample.gas["phoron"]/total_moles,0.1)
|
|
if(output&16)
|
|
signal.data["nitrogen"] = round(100*air_sample.gas["nitrogen"]/total_moles,0.1)
|
|
if(output&32)
|
|
signal.data["carbon_dioxide"] = round(100*air_sample.gas["carbon_dioxide"]/total_moles,0.1)
|
|
else
|
|
signal.data["oxygen"] = 0
|
|
signal.data["phoron"] = 0
|
|
signal.data["nitrogen"] = 0
|
|
signal.data["carbon_dioxide"] = 0
|
|
signal.data["sigtype"]="status"
|
|
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
|
|
|
|
|
/obj/machinery/air_sensor/proc/set_frequency(new_frequency)
|
|
radio_controller.remove_object(src, frequency)
|
|
frequency = new_frequency
|
|
radio_connection = radio_controller.add_object(src, frequency, RADIO_ATMOSIA)
|
|
|
|
/obj/machinery/air_sensor/initialize()
|
|
set_frequency(frequency)
|
|
|
|
obj/machinery/air_sensor/Destroy()
|
|
if(radio_controller)
|
|
radio_controller.remove_object(src,frequency)
|
|
..()
|
|
|
|
/obj/machinery/computer/general_air_control
|
|
icon = 'icons/obj/computer.dmi'
|
|
icon_state = "tank"
|
|
|
|
name = "Computer"
|
|
|
|
var/frequency = 1439
|
|
var/list/sensors = list()
|
|
|
|
var/list/sensor_information = list()
|
|
var/datum/radio_frequency/radio_connection
|
|
circuit = /obj/item/weapon/circuitboard/air_management
|
|
|
|
obj/machinery/computer/general_air_control/Destroy()
|
|
if(radio_controller)
|
|
radio_controller.remove_object(src, frequency)
|
|
..()
|
|
|
|
/obj/machinery/computer/general_air_control/attack_hand(mob/user)
|
|
if(..(user))
|
|
return
|
|
user << browse(return_text(),"window=computer")
|
|
user.set_machine(src)
|
|
onclose(user, "computer")
|
|
|
|
/obj/machinery/computer/general_air_control/process()
|
|
..()
|
|
src.updateUsrDialog()
|
|
|
|
/obj/machinery/computer/general_air_control/receive_signal(datum/signal/signal)
|
|
if(!signal || signal.encryption) return
|
|
|
|
var/id_tag = signal.data["tag"]
|
|
if(!id_tag || !sensors.Find(id_tag)) return
|
|
|
|
sensor_information[id_tag] = signal.data
|
|
|
|
/obj/machinery/computer/general_air_control/proc/return_text()
|
|
var/sensor_data
|
|
if(sensors.len)
|
|
for(var/id_tag in sensors)
|
|
var/long_name = sensors[id_tag]
|
|
var/list/data = sensor_information[id_tag]
|
|
var/sensor_part = "<B>[long_name]</B>:<BR>"
|
|
|
|
if(data)
|
|
if(data["pressure"])
|
|
sensor_part += " <B>Pressure:</B> [data["pressure"]] kPa<BR>"
|
|
if(data["temperature"])
|
|
sensor_part += " <B>Temperature:</B> [data["temperature"]] K<BR>"
|
|
if(data["oxygen"]||data["phoron"]||data["nitrogen"]||data["carbon_dioxide"])
|
|
sensor_part += " <B>Gas Composition :</B>"
|
|
if(data["oxygen"])
|
|
sensor_part += "[data["oxygen"]]% O2; "
|
|
if(data["nitrogen"])
|
|
sensor_part += "[data["nitrogen"]]% N; "
|
|
if(data["carbon_dioxide"])
|
|
sensor_part += "[data["carbon_dioxide"]]% CO2; "
|
|
if(data["phoron"])
|
|
sensor_part += "[data["phoron"]]% TX; "
|
|
sensor_part += "<HR>"
|
|
|
|
else
|
|
sensor_part = "<FONT color='red'>[long_name] can not be found!</FONT><BR>"
|
|
|
|
sensor_data += sensor_part
|
|
|
|
else
|
|
sensor_data = "No sensors connected."
|
|
|
|
var/output = {"<B>[name]</B><HR>
|
|
<B>Sensor Data:</B><HR><HR>[sensor_data]"}
|
|
|
|
return output
|
|
|
|
/obj/machinery/computer/general_air_control/proc/set_frequency(new_frequency)
|
|
radio_controller.remove_object(src, frequency)
|
|
frequency = new_frequency
|
|
radio_connection = radio_controller.add_object(src, frequency, RADIO_ATMOSIA)
|
|
|
|
/obj/machinery/computer/general_air_control/initialize()
|
|
set_frequency(frequency)
|
|
|
|
|
|
/obj/machinery/computer/general_air_control/large_tank_control
|
|
icon = 'icons/obj/computer.dmi'
|
|
icon_state = "tank"
|
|
|
|
frequency = 1441
|
|
var/input_tag
|
|
var/output_tag
|
|
|
|
var/list/input_info
|
|
var/list/output_info
|
|
|
|
var/input_flow_setting = 200
|
|
var/pressure_setting = ONE_ATMOSPHERE * 45
|
|
circuit = /obj/item/weapon/circuitboard/air_management/tank_control
|
|
|
|
|
|
/obj/machinery/computer/general_air_control/large_tank_control/return_text()
|
|
var/output = ..()
|
|
//if(signal.data)
|
|
// input_info = signal.data // Attempting to fix intake control -- TLE
|
|
|
|
output += "<B>Tank Control System</B><BR><BR>"
|
|
if(input_info)
|
|
var/power = (input_info["power"])
|
|
var/volume_rate = round(input_info["volume_rate"], 0.1)
|
|
output += "<B>Input</B>: [power?("Injecting"):("On Hold")] <A href='?src=\ref[src];in_refresh_status=1'>Refresh</A><BR>Flow Rate Limit: [volume_rate] L/s<BR>"
|
|
output += "Command: <A href='?src=\ref[src];in_toggle_injector=1'>Toggle Power</A> <A href='?src=\ref[src];in_set_flowrate=1'>Set Flow Rate</A><BR>"
|
|
|
|
else
|
|
output += "<FONT color='red'>ERROR: Can not find input port</FONT> <A href='?src=\ref[src];in_refresh_status=1'>Search</A><BR>"
|
|
|
|
output += "Flow Rate Limit: <A href='?src=\ref[src];adj_input_flow_rate=-100'>-</A> <A href='?src=\ref[src];adj_input_flow_rate=-10'>-</A> <A href='?src=\ref[src];adj_input_flow_rate=-1'>-</A> <A href='?src=\ref[src];adj_input_flow_rate=-0.1'>-</A> [round(input_flow_setting, 0.1)] L/s <A href='?src=\ref[src];adj_input_flow_rate=0.1'>+</A> <A href='?src=\ref[src];adj_input_flow_rate=1'>+</A> <A href='?src=\ref[src];adj_input_flow_rate=10'>+</A> <A href='?src=\ref[src];adj_input_flow_rate=100'>+</A><BR>"
|
|
|
|
output += "<BR>"
|
|
|
|
if(output_info)
|
|
var/power = (output_info["power"])
|
|
var/output_pressure = output_info["internal"]
|
|
output += {"<B>Output</B>: [power?("Open"):("On Hold")] <A href='?src=\ref[src];out_refresh_status=1'>Refresh</A><BR>
|
|
Max Output Pressure: [output_pressure] kPa<BR>"}
|
|
output += "Command: <A href='?src=\ref[src];out_toggle_power=1'>Toggle Power</A> <A href='?src=\ref[src];out_set_pressure=1'>Set Pressure</A><BR>"
|
|
|
|
else
|
|
output += "<FONT color='red'>ERROR: Can not find output port</FONT> <A href='?src=\ref[src];out_refresh_status=1'>Search</A><BR>"
|
|
|
|
output += "Max Output Pressure Set: <A href='?src=\ref[src];adj_pressure=-1000'>-</A> <A href='?src=\ref[src];adj_pressure=-100'>-</A> <A href='?src=\ref[src];adj_pressure=-10'>-</A> <A href='?src=\ref[src];adj_pressure=-1'>-</A> [pressure_setting] kPa <A href='?src=\ref[src];adj_pressure=1'>+</A> <A href='?src=\ref[src];adj_pressure=10'>+</A> <A href='?src=\ref[src];adj_pressure=100'>+</A> <A href='?src=\ref[src];adj_pressure=1000'>+</A><BR>"
|
|
|
|
return output
|
|
|
|
/obj/machinery/computer/general_air_control/large_tank_control/receive_signal(datum/signal/signal)
|
|
if(!signal || signal.encryption) return
|
|
|
|
var/id_tag = signal.data["tag"]
|
|
|
|
if(input_tag == id_tag)
|
|
input_info = signal.data
|
|
else if(output_tag == id_tag)
|
|
output_info = signal.data
|
|
else
|
|
..(signal)
|
|
|
|
/obj/machinery/computer/general_air_control/large_tank_control/Topic(href, href_list)
|
|
if(..())
|
|
return 1
|
|
|
|
if(href_list["adj_pressure"])
|
|
var/change = text2num(href_list["adj_pressure"])
|
|
pressure_setting = between(0, pressure_setting + change, 50*ONE_ATMOSPHERE)
|
|
spawn(1)
|
|
src.updateUsrDialog()
|
|
return 1
|
|
|
|
if(href_list["adj_input_flow_rate"])
|
|
var/change = text2num(href_list["adj_input_flow_rate"])
|
|
input_flow_setting = between(0, input_flow_setting + change, ATMOS_DEFAULT_VOLUME_PUMP + 500) //default flow rate limit for air injectors
|
|
spawn(1)
|
|
src.updateUsrDialog()
|
|
return 1
|
|
|
|
if(!radio_connection)
|
|
return 0
|
|
var/datum/signal/signal = new
|
|
signal.transmission_method = 1 //radio signal
|
|
signal.source = src
|
|
if(href_list["in_refresh_status"])
|
|
input_info = null
|
|
signal.data = list ("tag" = input_tag, "status" = 1)
|
|
. = 1
|
|
|
|
if(href_list["in_toggle_injector"])
|
|
input_info = null
|
|
signal.data = list ("tag" = input_tag, "power_toggle" = 1)
|
|
. = 1
|
|
|
|
if(href_list["in_set_flowrate"])
|
|
input_info = null
|
|
signal.data = list ("tag" = input_tag, "set_volume_rate" = "[input_flow_setting]")
|
|
. = 1
|
|
|
|
if(href_list["out_refresh_status"])
|
|
output_info = null
|
|
signal.data = list ("tag" = output_tag, "status" = 1)
|
|
. = 1
|
|
|
|
if(href_list["out_toggle_power"])
|
|
output_info = null
|
|
signal.data = list ("tag" = output_tag, "power_toggle" = 1)
|
|
. = 1
|
|
|
|
if(href_list["out_set_pressure"])
|
|
output_info = null
|
|
signal.data = list ("tag" = output_tag, "set_internal_pressure" = "[pressure_setting]")
|
|
. = 1
|
|
|
|
signal.data["sigtype"]="command"
|
|
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
|
|
|
spawn(5)
|
|
src.updateUsrDialog()
|
|
|
|
/obj/machinery/computer/general_air_control/supermatter_core
|
|
icon = 'icons/obj/computer.dmi'
|
|
icon_state = "tank"
|
|
|
|
frequency = 1438
|
|
var/input_tag
|
|
var/output_tag
|
|
|
|
var/list/input_info
|
|
var/list/output_info
|
|
|
|
var/input_flow_setting = 700
|
|
var/pressure_setting = 100
|
|
circuit = /obj/item/weapon/circuitboard/air_management/supermatter_core
|
|
|
|
|
|
/obj/machinery/computer/general_air_control/supermatter_core/return_text()
|
|
var/output = ..()
|
|
//if(signal.data)
|
|
// input_info = signal.data // Attempting to fix intake control -- TLE
|
|
|
|
output += "<B>Core Cooling Control System</B><BR><BR>"
|
|
if(input_info)
|
|
var/power = (input_info["power"])
|
|
var/volume_rate = round(input_info["volume_rate"], 0.1)
|
|
output += "<B>Coolant Input</B>: [power?("Injecting"):("On Hold")] <A href='?src=\ref[src];in_refresh_status=1'>Refresh</A><BR>Flow Rate Limit: [volume_rate] L/s<BR>"
|
|
output += "Command: <A href='?src=\ref[src];in_toggle_injector=1'>Toggle Power</A> <A href='?src=\ref[src];in_set_flowrate=1'>Set Flow Rate</A><BR>"
|
|
|
|
else
|
|
output += "<FONT color='red'>ERROR: Can not find input port</FONT> <A href='?src=\ref[src];in_refresh_status=1'>Search</A><BR>"
|
|
|
|
output += "Flow Rate Limit: <A href='?src=\ref[src];adj_input_flow_rate=-100'>-</A> <A href='?src=\ref[src];adj_input_flow_rate=-10'>-</A> <A href='?src=\ref[src];adj_input_flow_rate=-1'>-</A> <A href='?src=\ref[src];adj_input_flow_rate=-0.1'>-</A> [round(input_flow_setting, 0.1)] L/s <A href='?src=\ref[src];adj_input_flow_rate=0.1'>+</A> <A href='?src=\ref[src];adj_input_flow_rate=1'>+</A> <A href='?src=\ref[src];adj_input_flow_rate=10'>+</A> <A href='?src=\ref[src];adj_input_flow_rate=100'>+</A><BR>"
|
|
|
|
output += "<BR>"
|
|
|
|
if(output_info)
|
|
var/power = (output_info["power"])
|
|
var/pressure_limit = output_info["external"]
|
|
output += {"<B>Core Outpump</B>: [power?("Open"):("On Hold")] <A href='?src=\ref[src];out_refresh_status=1'>Refresh</A><BR>
|
|
Min Core Pressure: [pressure_limit] kPa<BR>"}
|
|
output += "Command: <A href='?src=\ref[src];out_toggle_power=1'>Toggle Power</A> <A href='?src=\ref[src];out_set_pressure=1'>Set Pressure</A><BR>"
|
|
|
|
else
|
|
output += "<FONT color='red'>ERROR: Can not find output port</FONT> <A href='?src=\ref[src];out_refresh_status=1'>Search</A><BR>"
|
|
|
|
output += "Min Core Pressure Set: <A href='?src=\ref[src];adj_pressure=-100'>-</A> <A href='?src=\ref[src];adj_pressure=-50'>-</A> <A href='?src=\ref[src];adj_pressure=-10'>-</A> <A href='?src=\ref[src];adj_pressure=-1'>-</A> [pressure_setting] kPa <A href='?src=\ref[src];adj_pressure=1'>+</A> <A href='?src=\ref[src];adj_pressure=10'>+</A> <A href='?src=\ref[src];adj_pressure=50'>+</A> <A href='?src=\ref[src];adj_pressure=100'>+</A><BR>"
|
|
|
|
return output
|
|
|
|
/obj/machinery/computer/general_air_control/supermatter_core/receive_signal(datum/signal/signal)
|
|
if(!signal || signal.encryption) return
|
|
|
|
var/id_tag = signal.data["tag"]
|
|
|
|
if(input_tag == id_tag)
|
|
input_info = signal.data
|
|
else if(output_tag == id_tag)
|
|
output_info = signal.data
|
|
else
|
|
..(signal)
|
|
|
|
/obj/machinery/computer/general_air_control/supermatter_core/Topic(href, href_list)
|
|
if(..())
|
|
return 1
|
|
|
|
if(href_list["adj_pressure"])
|
|
var/change = text2num(href_list["adj_pressure"])
|
|
pressure_setting = between(0, pressure_setting + change, 10*ONE_ATMOSPHERE)
|
|
spawn(1)
|
|
src.updateUsrDialog()
|
|
return 1
|
|
|
|
if(href_list["adj_input_flow_rate"])
|
|
var/change = text2num(href_list["adj_input_flow_rate"])
|
|
input_flow_setting = between(0, input_flow_setting + change, ATMOS_DEFAULT_VOLUME_PUMP + 500) //default flow rate limit for air injectors
|
|
spawn(1)
|
|
src.updateUsrDialog()
|
|
return 1
|
|
|
|
if(!radio_connection)
|
|
return 0
|
|
var/datum/signal/signal = new
|
|
signal.transmission_method = 1 //radio signal
|
|
signal.source = src
|
|
if(href_list["in_refresh_status"])
|
|
input_info = null
|
|
signal.data = list ("tag" = input_tag, "status" = 1)
|
|
. = 1
|
|
|
|
if(href_list["in_toggle_injector"])
|
|
input_info = null
|
|
signal.data = list ("tag" = input_tag, "power_toggle" = 1)
|
|
. = 1
|
|
|
|
if(href_list["in_set_flowrate"])
|
|
input_info = null
|
|
signal.data = list ("tag" = input_tag, "set_volume_rate" = "[input_flow_setting]")
|
|
. = 1
|
|
|
|
if(href_list["out_refresh_status"])
|
|
output_info = null
|
|
signal.data = list ("tag" = output_tag, "status" = 1)
|
|
. = 1
|
|
|
|
if(href_list["out_toggle_power"])
|
|
output_info = null
|
|
signal.data = list ("tag" = output_tag, "power_toggle" = 1)
|
|
. = 1
|
|
|
|
if(href_list["out_set_pressure"])
|
|
output_info = null
|
|
signal.data = list ("tag" = output_tag, "set_external_pressure" = "[pressure_setting]", "checks" = 1)
|
|
. = 1
|
|
|
|
signal.data["sigtype"]="command"
|
|
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
|
|
|
spawn(5)
|
|
src.updateUsrDialog()
|
|
|
|
/obj/machinery/computer/general_air_control/fuel_injection
|
|
icon = 'icons/obj/computer.dmi'
|
|
icon_state = "atmos"
|
|
|
|
var/device_tag
|
|
var/list/device_info
|
|
|
|
var/automation = 0
|
|
|
|
var/cutoff_temperature = 2000
|
|
var/on_temperature = 1200
|
|
circuit = /obj/item/weapon/circuitboard/air_management/injector_control
|
|
|
|
/obj/machinery/computer/general_air_control/fuel_injection/process()
|
|
if(automation)
|
|
if(!radio_connection)
|
|
return 0
|
|
|
|
var/injecting = 0
|
|
for(var/id_tag in sensor_information)
|
|
var/list/data = sensor_information[id_tag]
|
|
if(data["temperature"])
|
|
if(data["temperature"] >= cutoff_temperature)
|
|
injecting = 0
|
|
break
|
|
if(data["temperature"] <= on_temperature)
|
|
injecting = 1
|
|
|
|
var/datum/signal/signal = new
|
|
signal.transmission_method = 1 //radio signal
|
|
signal.source = src
|
|
|
|
signal.data = list(
|
|
"tag" = device_tag,
|
|
"power" = injecting,
|
|
"sigtype"="command"
|
|
)
|
|
|
|
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
|
|
|
..()
|
|
|
|
/obj/machinery/computer/general_air_control/fuel_injection/return_text()
|
|
var/output = ..()
|
|
|
|
output += "<B>Fuel Injection System</B><BR>"
|
|
if(device_info)
|
|
var/power = device_info["power"]
|
|
var/volume_rate = device_info["volume_rate"]
|
|
output += {"Status: [power?("Injecting"):("On Hold")] <A href='?src=\ref[src];refresh_status=1'>Refresh</A><BR>
|
|
Rate: [volume_rate] L/sec<BR>"}
|
|
|
|
if(automation)
|
|
output += "Automated Fuel Injection: <A href='?src=\ref[src];toggle_automation=1'>Engaged</A><BR>"
|
|
output += "Injector Controls Locked Out<BR>"
|
|
else
|
|
output += "Automated Fuel Injection: <A href='?src=\ref[src];toggle_automation=1'>Disengaged</A><BR>"
|
|
output += "Injector: <A href='?src=\ref[src];toggle_injector=1'>Toggle Power</A> <A href='?src=\ref[src];injection=1'>Inject (1 Cycle)</A><BR>"
|
|
|
|
else
|
|
output += "<FONT color='red'>ERROR: Can not find device</FONT> <A href='?src=\ref[src];refresh_status=1'>Search</A><BR>"
|
|
|
|
return output
|
|
|
|
/obj/machinery/computer/general_air_control/fuel_injection/receive_signal(datum/signal/signal)
|
|
if(!signal || signal.encryption) return
|
|
|
|
var/id_tag = signal.data["tag"]
|
|
|
|
if(device_tag == id_tag)
|
|
device_info = signal.data
|
|
else
|
|
..(signal)
|
|
|
|
/obj/machinery/computer/general_air_control/fuel_injection/Topic(href, href_list)
|
|
if(..())
|
|
return
|
|
|
|
if(href_list["refresh_status"])
|
|
device_info = null
|
|
if(!radio_connection)
|
|
return 0
|
|
|
|
var/datum/signal/signal = new
|
|
signal.transmission_method = 1 //radio signal
|
|
signal.source = src
|
|
signal.data = list(
|
|
"tag" = device_tag,
|
|
"status" = 1,
|
|
"sigtype"="command"
|
|
)
|
|
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
|
|
|
if(href_list["toggle_automation"])
|
|
automation = !automation
|
|
|
|
if(href_list["toggle_injector"])
|
|
device_info = null
|
|
if(!radio_connection)
|
|
return 0
|
|
|
|
var/datum/signal/signal = new
|
|
signal.transmission_method = 1 //radio signal
|
|
signal.source = src
|
|
signal.data = list(
|
|
"tag" = device_tag,
|
|
"power_toggle" = 1,
|
|
"sigtype"="command"
|
|
)
|
|
|
|
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
|
|
|
if(href_list["injection"])
|
|
if(!radio_connection)
|
|
return 0
|
|
|
|
var/datum/signal/signal = new
|
|
signal.transmission_method = 1 //radio signal
|
|
signal.source = src
|
|
signal.data = list(
|
|
"tag" = device_tag,
|
|
"inject" = 1,
|
|
"sigtype"="command"
|
|
)
|
|
|
|
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
|
|
|
|
|
|
|
|